메뉴 건너뛰기




Volumn 33, Issue 2, 2005, Pages 83-99

Conjugate of bovine hemoglobin and human serum albumin as a candidate for blood substitute: Characteristics and effects on rats

Author keywords

Blood substitutes; Bovine hemoglobin; Conjugate; Glutaraldehyde; Human serum albumin

Indexed keywords

BIOLOGICAL ORGANS; BIOMEDICAL ENGINEERING; BLOOD SUBSTITUTES; MOLECULAR WEIGHT; OLIGOMERS; PROTEINS;

EID: 20044396382     PISSN: 10731199     EISSN: None     Source Type: Journal    
DOI: 10.1081/BIO-200055841     Document Type: Article
Times cited : (9)

References (23)
  • 1
    • 0031822162 scopus 로고    scopus 로고
    • Ultrastructural effects of intravascularly injected polyethylene glycol-hemoglobin in intestinal mucosa
    • Baldwin, A.L., Wilson, L.M., Valeski, J.E. (1998). Ultrastructural effects of intravascularly injected polyethylene glycol-hemoglobin in intestinal mucosa. Am. J. Physiol. 275: H615-H625.
    • (1998) Am. J. Physiol. , vol.275
    • Baldwin, A.L.1    Wilson, L.M.2    Valeski, J.E.3
  • 2
    • 37049233007 scopus 로고
    • Semi-permeable microcapsules
    • Chang, T.M.S. (1964). Semi-permeable microcapsules. Science 146: 524-525.
    • (1964) Science , vol.146 , pp. 524-525
    • Chang, T.M.S.1
  • 5
    • 0026737507 scopus 로고
    • Effect of a single replacement of one of ringer lactate, hypertonic saline/Dextran, 7g% albumin, stroma-free hemoglobin, o-raffinose polyhemoglobin or whole blood on the long term survival of unanesthetized rates with lethal hemorrhagic shock after 67% acute blood loss
    • Chang, T.M.S., Varma, R. (1992). Effect of a single replacement of one of ringer lactate, hypertonic saline/Dextran, 7g% albumin, stroma-free hemoglobin, o-raffinose polyhemoglobin or whole blood on the long term survival of unanesthetized rates with lethal hemorrhagic shock after 67% acute blood loss. Biomat Art. Cells & Immob. Biotech. 20(2-4): 503-510.
    • (1992) Biomat Art. Cells & Immob. Biotech. , vol.20 , Issue.2-4 , pp. 503-510
    • Chang, T.M.S.1    Varma, R.2
  • 6
    • 0035008248 scopus 로고    scopus 로고
    • Safety and efficacy of o-raffinose cross-linked human hemoglobin (Hemolink) in cardiac surgery
    • Cheng, D.C. (2001). Safety and efficacy of o-raffinose cross-linked human hemoglobin (Hemolink) in cardiac surgery. Can J Anaesth. 48(4 suppl): S41-48.
    • (2001) Can. J. Anaesth. , vol.48 , Issue.4 SUPPL.
    • Cheng, D.C.1
  • 7
    • 0343852124 scopus 로고    scopus 로고
    • Site-specific modifications and toxicity of blood substitutes, the case of diaspirin cross-linked hemoglobin
    • D'Agnillo, F., Alayash, A.I. (2000). Site-specific modifications and toxicity of blood substitutes, the case of diaspirin cross-linked hemoglobin. Advanced Drug Delivery Reviews 40: 199-212.
    • (2000) Advanced Drug Delivery Reviews , vol.40 , pp. 199-212
    • D'Agnillo, F.1    Alayash, A.I.2
  • 8
    • 57349153078 scopus 로고
    • The standardization of hemoglobin measurement
    • Drabkin, D. (1949). The standardization of hemoglobin measurement. Am. J. Med. Sci. 217: 710-711.
    • (1949) Am. J. Med. Sci. , vol.217 , pp. 710-711
    • Drabkin, D.1
  • 9
    • 0001999021 scopus 로고
    • Acute renal failure associated with myoglobinuria and hemoglobinuria
    • B.M. Brenner, J.M. Lazarus, Eds., New York: Churchill Livingstone
    • Dubrow, A., Flamenbaum, W. (1988). Acute renal failure associated with myoglobinuria and hemoglobinuria, in Acute Renal Failure, B.M. Brenner, J.M. Lazarus, Eds., New York: Churchill Livingstone, 279-293.
    • (1988) Acute Renal Failure , pp. 279-293
    • Dubrow, A.1    Flamenbaum, W.2
  • 10
    • 0000400174 scopus 로고
    • Microdetermination of oxyhemoglobin, methemoglobin, and sulfhemoglobin in a single sample of blood
    • Evelyn, K.A., Malloy, H.T. (1938). Microdetermination of oxyhemoglobin, methemoglobin, and sulfhemoglobin in a single sample of blood. J. Biol. Chem. 126: 655-662.
    • (1938) J. Biol. Chem. , vol.126 , pp. 655-662
    • Evelyn, K.A.1    Malloy, H.T.2
  • 11
    • 0002223338 scopus 로고    scopus 로고
    • Perflubron-based emulsion: Efficacy as temporary oxygen carrier
    • R.M. Winslow, K. Vandegriff, M. Intaglietta, Eds., Boston: Brikhäuser
    • Flaim, S. (1997). Perflubron-based emulsion: efficacy as temporary oxygen carrier, in Advances in Blood Substitutes, Industrial Opportunities and Medical Challenges, R.M. Winslow, K. Vandegriff, M. Intaglietta, Eds., Boston: Brikhäuser.
    • (1997) Advances in Blood Substitutes, Industrial Opportunities and Medical Challenges
    • Flaim, S.1
  • 12
    • 0037434443 scopus 로고    scopus 로고
    • Solid phase adsorption method for preparation of bovine serum albumin-bovine hemoglobin conjugate
    • Hu, T., Su, Z.G. (2003). Solid phase adsorption method for preparation of bovine serum albumin-bovine hemoglobin conjugate. Journal of Biotechnology 100(3): 267-275.
    • (2003) Journal of Biotechnology , vol.100 , Issue.3 , pp. 267-275
    • Hu, T.1    Su, Z.G.2
  • 13
    • 3042551057 scopus 로고    scopus 로고
    • Purification of hemoglobin by ion exchange chromatography in flow-through mode with PEG as an escort
    • Lu, X.L., Zhao, D.X., Su, Z.G. (2004). Purification of hemoglobin by ion exchange chromatography in flow-through mode with PEG as an escort. Artif. Cells, Blood Substit. and Biotechnol. 32(2): 209-227.
    • (2004) Artif. Cells, Blood Substit. and Biotechnol. , vol.32 , Issue.2 , pp. 209-227
    • Lu, X.L.1    Zhao, D.X.2    Su, Z.G.3
  • 14
    • 0026344691 scopus 로고
    • Preparation, properties, and plasma retention of human hemoglobin derivatives: Comparison of uncrosslinked carboxymethylated hemoglobin with crosslinked tetrameric hemoglobin
    • Manning, L.R., Morgan, S., Beavis, R.C., Chait, B.T., Manning, J.M., Hess, J.R., Cross, M., Currell, D.L., Marini, M.A., Winslow, R.M. (1991). Preparation, properties, and plasma retention of human hemoglobin derivatives: comparison of uncrosslinked carboxymethylated hemoglobin with crosslinked tetrameric hemoglobin. Proc. Natl. Acad. Sci. USA 88(8): 3329-3333.
    • (1991) Proc. Natl. Acad. Sci. USA , vol.88 , Issue.8 , pp. 3329-3333
    • Manning, L.R.1    Morgan, S.2    Beavis, R.C.3    Chait, B.T.4    Manning, J.M.5    Hess, J.R.6    Cross, M.7    Currell, D.L.8    Marini, M.A.9    Winslow, R.M.10
  • 18
    • 0033984989 scopus 로고    scopus 로고
    • Synthesis and physicochemical characterization of a series of hemoglobin-based oxygen carriers: Objective comparison between cellular and acellular types
    • Sakai, H., Yuasa, M., Onuma, H., Takeoka, S., Tsuchida, E. (2000). Synthesis and physicochemical characterization of a series of hemoglobin-based oxygen carriers: objective comparison between cellular and acellular types. Bioconjugate Chem., 11: 56-64.
    • (2000) Bioconjugate Chem. , vol.11 , pp. 56-64
    • Sakai, H.1    Yuasa, M.2    Onuma, H.3    Takeoka, S.4    Tsuchida, E.5
  • 19
    • 0023864939 scopus 로고
    • Interaction of plasma proteins with negatively charged sites on the pulmonary capillary endothelium of the rat
    • Schneeberger, E.E. (1988). Interaction of plasma proteins with negatively charged sites on the pulmonary capillary endothelium of the rat. Cell Tissue Res. 251: 417-423.
    • (1988) Cell Tissue Res. , vol.251 , pp. 417-423
    • Schneeberger, E.E.1
  • 21
    • 0037885022 scopus 로고    scopus 로고
    • Current status of blood substitute research: Towards a new paradigm
    • Winslow, R. W. (2003). Current status of blood substitute research: towards a new paradigm. Journal of Internal Medicine 253: 508-517.
    • (2003) Journal of Internal Medicine , vol.253 , pp. 508-517
    • Winslow, R.W.1
  • 22
    • 3042765095 scopus 로고
    • The toxicity of hemoglobin
    • R.M. Winslow, Ed., Baltimore: John Hopkins University Press
    • Winslow, R.M. (1993). The toxicity of hemoglobin, in Hemoglobin-Based Red Blood Cell Substitutes, R.M. Winslow, Ed., Baltimore: John Hopkins University Press, 136-163.
    • (1993) Hemoglobin-Based Red Blood Cell Substitutes , pp. 136-163
    • Winslow, R.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.