메뉴 건너뛰기




Volumn 21, Issue 6, 2005, Pages 831-835

Navigator-gated three-dimensional MR angiography of the pulmonary arteries using steady-state free precession

Author keywords

Breathhold; Navigator; Pulmonary arteries; SSFP; Steady state free precession

Indexed keywords

ADULT; ARTICLE; ARTIFACT; BREATH HOLDING; CONTROLLED STUDY; HUMAN; HUMAN EXPERIMENT; IMAGE QUALITY; MAGNETIC RESONANCE ANGIOGRAPHY; MALE; NAVIGATOR GATED THREE DIMENSIONAL MAGNETIC RESONANCE ANGIOGRAPHY; NORMAL HUMAN; PRIORITY JOURNAL; PULMONARY ARTERY; SIGNAL NOISE RATIO; STEADY STATE; THREE DIMENSIONAL IMAGING; VOLUNTEER; WAVEFORM;

EID: 20044390389     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20334     Document Type: Article
Times cited : (20)

References (20)
  • 3
    • 0037062132 scopus 로고    scopus 로고
    • Comparison of contrast-enhanced MRA and DSA for the diagnosis of pulmonary embolism: Results of a prospective study in 141 consecutive patients with an abnormal perfusion lung scan
    • Oudkerk M, Van Beek EJR, Wielopolski P, et al. Comparison of contrast-enhanced MRA and DSA for the diagnosis of pulmonary embolism: results of a prospective study in 141 consecutive patients with an abnormal perfusion lung scan. Lancet 2002;359:1643-1647.
    • (2002) Lancet , vol.359 , pp. 1643-1647
    • Oudkerk, M.1    Van Beek, E.J.R.2    Wielopolski, P.3
  • 4
    • 0035104550 scopus 로고    scopus 로고
    • Dynamic 3D MR angiography of the pulmonary arteries in under four seconds
    • Goyen M, Laub G, Ladd ME, et al. Dynamic 3D MR angiography of the pulmonary arteries in under four seconds. J Magn Reson Imaging 2001;13:372-377.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 372-377
    • Goyen, M.1    Laub, G.2    Ladd, M.E.3
  • 5
    • 0024453449 scopus 로고
    • Adaptive technique for high-definition MR imaging of moving structures
    • Ehman RL, Felmlee JP. Adaptive technique for high-definition MR imaging of moving structures. Radiology 1989;173:255-263.
    • (1989) Radiology , vol.173 , pp. 255-263
    • Ehman, R.L.1    Felmlee, J.P.2
  • 6
    • 0030026702 scopus 로고    scopus 로고
    • Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography
    • Wang Y, Rossman PJ, Grimm RC, Riederer SJ, Ehman RL. Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 1996;198:55-60.
    • (1996) Radiology , vol.198 , pp. 55-60
    • Wang, Y.1    Rossman, P.J.2    Grimm, R.C.3    Riederer, S.J.4    Ehman, R.L.5
  • 7
    • 0032817865 scopus 로고    scopus 로고
    • Optimization of realtime adaptive navigator correction for 3D magnetic resonance coronary angiography
    • Nagel E, Bornstedt A, Schnackenburg B, Hug J, Oswald H, Fleck E. Optimization of realtime adaptive navigator correction for 3D magnetic resonance coronary angiography. Magn Reson Med 1999;42:408-411.
    • (1999) Magn Reson Med , vol.42 , pp. 408-411
    • Nagel, E.1    Bornstedt, A.2    Schnackenburg, B.3    Hug, J.4    Oswald, H.5    Fleck, E.6
  • 9
    • 0035195107 scopus 로고    scopus 로고
    • A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography
    • Du YP, McVeigh ER, Bluemke DA, Silber HA, Foo TK. A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography. Int J Cardiovasc Imaging 2001;17:287-294.
    • (2001) Int J Cardiovasc Imaging , vol.17 , pp. 287-294
    • Du, Y.P.1    McVeigh, E.R.2    Bluemke, D.A.3    Silber, H.A.4    Foo, T.K.5
  • 10
    • 0036828308 scopus 로고    scopus 로고
    • Navigator-gated free-breathing three-dimensional balanced fast field echo (TrueFISP) coronary magnetic resonance angiography
    • Spuentrup E, Bornert P, Botnar RM, Groen JP, Manning WJ, Stuber M. Navigator-gated free-breathing three-dimensional balanced fast field echo (TrueFISP) coronary magnetic resonance angiography. Invest Radiol 2002;37:637-642.
    • (2002) Invest Radiol , vol.37 , pp. 637-642
    • Spuentrup, E.1    Bornert, P.2    Botnar, R.M.3    Groen, J.P.4    Manning, W.J.5    Stuber, M.6
  • 11
    • 0037370055 scopus 로고    scopus 로고
    • Coronary artery imaging with real-time navigator three-dimensional turbo-field-echo MR coronary angiography: Initial experience
    • Bogaert J, Kuzo R, Dymarkowski S, Beckers R, Piessens J, Rademakers FE. Coronary artery imaging with real-time navigator three-dimensional turbo-field-echo MR coronary angiography: initial experience. Radiology 2003;226:707-716.
    • (2003) Radiology , vol.226 , pp. 707-716
    • Bogaert, J.1    Kuzo, R.2    Dymarkowski, S.3    Beckers, R.4    Piessens, J.5    Rademakers, F.E.6
  • 12
    • 0345689656 scopus 로고    scopus 로고
    • Three-dimensional respiratory-gated coronary MR angiography with reference to X-ray coronary angiography
    • Ikonen AE, Manninen HI, Vainio P, et al. Three-dimensional respiratory-gated coronary MR angiography with reference to X-ray coronary angiography. Acta Radiol 2003;44:583-589.
    • (2003) Acta Radiol , vol.44 , pp. 583-589
    • Ikonen, A.E.1    Manninen, H.I.2    Vainio, P.3
  • 13
    • 1542373637 scopus 로고    scopus 로고
    • Correlation between magnetic resonance angiography (MRA) and quantitative coronary angiography (QCA) in ectatic coronary vessels
    • Mavrogeni SI, Manginas A, Papadakis E, et al. Correlation between magnetic resonance angiography (MRA) and quantitative coronary angiography (QCA) in ectatic coronary vessels. J Cardiovasc Magn Reson 2004;6:17-23.
    • (2004) J Cardiovasc Magn Reson , vol.6 , pp. 17-23
    • Mavrogeni, S.I.1    Manginas, A.2    Papadakis, E.3
  • 14
    • 0029758749 scopus 로고    scopus 로고
    • 3D MR angiography of pulmonary arteries using real-time navigator gating and magnetization preparation
    • Wang Y, Rossman PJ, Grimm RC, Wilman AH, Riederer SJ, Ehman RL. 3D MR angiography of pulmonary arteries using real-time navigator gating and magnetization preparation. Magn Reson Med 1996;36:579-587.
    • (1996) Magn Reson Med , vol.36 , pp. 579-587
    • Wang, Y.1    Rossman, P.J.2    Grimm, R.C.3    Wilman, A.H.4    Riederer, S.J.5    Ehman, R.L.6
  • 15
    • 0032968308 scopus 로고    scopus 로고
    • Pulmonary MR angiography with ultrasmall superparamagnetic iron oxide particles as a blood pool agent and a navigator echo for respiratory gating: Pilot study
    • Ahlstrom KH, Johansson LO, Rodenburg JB, Ragnarsson AS, Akeson P, Borseth A. Pulmonary MR angiography with ultrasmall superparamagnetic iron oxide particles as a blood pool agent and a navigator echo for respiratory gating: pilot study. Radiology 1999;211:865-869.
    • (1999) Radiology , vol.211 , pp. 865-869
    • Ahlstrom, K.H.1    Johansson, L.O.2    Rodenburg, J.B.3    Ragnarsson, A.S.4    Akeson, P.5    Borseth, A.6
  • 17
    • 0036845522 scopus 로고    scopus 로고
    • Single-breathhold 3D-TrueFISP cine cardiac imaging
    • Jung BA, Hennig J, Scheffler K. Single-breathhold 3D-TrueFISP cine cardiac imaging. Magn Reson Med 2002;48:921-925.
    • (2002) Magn Reson Med , vol.48 , pp. 921-925
    • Jung, B.A.1    Hennig, J.2    Scheffler, K.3
  • 18
    • 0033302586 scopus 로고    scopus 로고
    • Breathhold three-dimensional coronary magnetic resonance angiography using real-time navigator technology
    • Stuber M, Botnar RM, Danias PG, Kissinger KV, Manning WJ. Breathhold three-dimensional coronary magnetic resonance angiography using real-time navigator technology. J Cardiovasc Magn Reson 1999;1:233-238.
    • (1999) J Cardiovasc Magn Reson , vol.1 , pp. 233-238
    • Stuber, M.1    Botnar, R.M.2    Danias, P.G.3    Kissinger, K.V.4    Manning, W.J.5
  • 19
    • 2342629981 scopus 로고    scopus 로고
    • Fast, three-dimensional free-breathing MR imaging of myocardial infarction: A feasibility study
    • Saranathan M, Rochitte CE, Foo TK. Fast, three-dimensional free-breathing MR imaging of myocardial infarction: a feasibility study. Magn Reson Med 2004;51:1055-1060.
    • (2004) Magn Reson Med , vol.51 , pp. 1055-1060
    • Saranathan, M.1    Rochitte, C.E.2    Foo, T.K.3
  • 20
    • 0242385495 scopus 로고    scopus 로고
    • Flow effects in balanced steady state free precession imaging
    • Markl M, Alley MT, Elkins CJ, Pelc NJ. Flow effects in balanced steady state free precession imaging. Magn Reson Med 2003;50:892-903.
    • (2003) Magn Reson Med , vol.50 , pp. 892-903
    • Markl, M.1    Alley, M.T.2    Elkins, C.J.3    Pelc, N.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.