메뉴 건너뛰기




Volumn 84, Issue 12, 2005, Pages 1175-1180

Beat-to-beat estimate of fetal cardiac time intervals using magnetocardiography: Longitudinal charts of normality ranges and individual trends

Author keywords

Fetal cardiac time intervals (fCTI); Fetal magnetocardiography (fMCG); Independent component analysis (ICA); Prenatal diagnosis; Signal processing

Indexed keywords

ADULT; ARTICLE; CALCULATION; FETUS; FETUS HEART; HEART ELECTROPHYSIOLOGY; HEART FUNCTION TEST; HUMAN; HUMAN EXPERIMENT; INDEPENDENT COMPONENT ANALYSIS; MAGNETOCARDIOGRAPHY; NORMAL HUMAN; P WAVE; PRENATAL DIAGNOSIS; PRIORITY JOURNAL; SIGNAL PROCESSING; T WAVE;

EID: 20044378406     PISSN: 00016349     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.0001-6349.2005.00855.x     Document Type: Article
Times cited : (14)

References (31)
  • 1
    • 0035231729 scopus 로고    scopus 로고
    • Monitoring the fetal heart non-invasively: A review of methods
    • Peters M, Crowe J, Piéri JF et al. Monitoring the fetal heart non-invasively: a review of methods. J Perinat Med 2001; 29: 408-16.
    • (2001) J Perinat Med , vol.29 , pp. 408-416
    • Peters, M.1    Crowe, J.2    Piéri, J.F.3
  • 2
    • 0242494235 scopus 로고    scopus 로고
    • Review of electromagnetic source investigations of the fetal heart
    • Lewis MJ. Review of electromagnetic source investigations of the fetal heart. Med Eng Phys 2003; 25: 801-10.
    • (2003) Med Eng Phys , vol.25 , pp. 801-810
    • Lewis, M.J.1
  • 3
    • 0038507616 scopus 로고    scopus 로고
    • Non-invasive fetal electrocardiography in singleton and multiple pregnancies
    • Taylor MJ, Smith MJ, Thomas M et al. Non-invasive fetal electrocardiography in singleton and multiple pregnancies. Br J Obstet Gynaecol 2003; 110: 668-78.
    • (2003) Br J Obstet Gynaecol , vol.110 , pp. 668-678
    • Taylor, M.J.1    Smith, M.J.2    Thomas, M.3
  • 4
    • 0036658463 scopus 로고    scopus 로고
    • The influence of fetoabdominal tissues on fetal ECGs and MCGs
    • Stinstra JG, Peters MJ. The influence of fetoabdominal tissues on fetal ECGs and MCGs. Arch Physiol Biochem 2002; 110: 165-76.
    • (2002) Arch Physiol Biochem , vol.110 , pp. 165-176
    • Stinstra, J.G.1    Peters, M.J.2
  • 5
    • 0036979868 scopus 로고    scopus 로고
    • The coincidence of fetal magnetocardiography and direct electrocardiography in a case of fetal atrial flutter due to intracardiac tumor
    • Hosono T, Kanegawa T, Chiba Y, Kandori A, Tsukada K. The coincidence of fetal magnetocardiography and direct electrocardiography in a case of fetal atrial flutter due to intracardiac tumor. Fetal Diagn Ther 2002; 17: 331-3.
    • (2002) Fetal Diagn Ther , vol.17 , pp. 331-333
    • Hosono, T.1    Kanegawa, T.2    Chiba, Y.3    Kandori, A.4    Tsukada, K.5
  • 7
    • 0035423395 scopus 로고    scopus 로고
    • Usefulness of magnetocardiography for the investigation of fetal arrhythmias
    • Menendez T, Achenbach S, Beinder E et al. Usefulness of magnetocardiography for the investigation of fetal arrhythmias. Am J Cardiol 2001; 88: 334-6.
    • (2001) Am J Cardiol , vol.88 , pp. 334-336
    • Menendez, T.1    Achenbach, S.2    Beinder, E.3
  • 8
    • 0037458130 scopus 로고    scopus 로고
    • Magnetocardiographic rhythm patterns at initiation and termination of fetal supraventricular tachycardia
    • Wakai RT, Strasburger JF, Li Z, Deal BJ, Gotteiner NL. Magnetocardiographic rhythm patterns at initiation and termination of fetal supraventricular tachycardia. Circulation 2003; 107: 307-12.
    • (2003) Circulation , vol.107 , pp. 307-312
    • Wakai, R.T.1    Strasburger, J.F.2    Li, Z.3    Deal, B.J.4    Gotteiner, N.L.5
  • 9
    • 11144327117 scopus 로고    scopus 로고
    • Characterization of fetal arrhythmias by means of fetal magnetocardiography in three cases of difficult ultrasonographic imaging
    • Comani S, Liberati M, Mantini D et al. Characterization of fetal arrhythmias by means of fetal magnetocardiography in three cases of difficult ultrasonographic imaging. Pacing Clin Electrophysiol 2004; 27: 1647-55.
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 1647-1655
    • Comani, S.1    Liberati, M.2    Mantini, D.3
  • 10
    • 0035063076 scopus 로고    scopus 로고
    • The application of fetal magnetocardiography (FMCG) to investigate fetal arrhythmias and congenital heart defects (CHD)
    • Kähler C, Grimm B, Schleussner E et al. The application of fetal magnetocardiography (FMCG) to investigate fetal arrhythmias and congenital heart defects (CHD). Prenat Diagn 2001; 21: 176-82.
    • (2001) Prenat Diagn , vol.21 , pp. 176-182
    • Kähler, C.1    Grimm, B.2    Schleussner, E.3
  • 11
    • 0141627632 scopus 로고    scopus 로고
    • Influence of intrauterine growth restriction on cardiac time intervals evaluated by fetal magnetocardiography
    • Grimm B, Kähler C, Schleussner E, Schneider U, Haueisen J, Seewald HJ. Influence of intrauterine growth restriction on cardiac time intervals evaluated by fetal magnetocardiography. Early Hum Dev 2003; 74: 1-11.
    • (2003) Early Hum Dev , vol.74 , pp. 1-11
    • Grimm, B.1    Kähler, C.2    Schleussner, E.3    Schneider, U.4    Haueisen, J.5    Seewald, H.J.6
  • 12
    • 0034918932 scopus 로고    scopus 로고
    • Detection of cardiac hypertrophy in the fetus by approximation of the current dipole using magnetocardiography
    • Horigome H, Shiono J, Shigemitsu S et al. Detection of cardiac hypertrophy in the fetus by approximation of the current dipole using magnetocardiography. Pediatric Res 2001; 50: 242-5.
    • (2001) Pediatric Res , vol.50 , pp. 242-245
    • Horigome, H.1    Shiono, J.2    Shigemitsu, S.3
  • 13
    • 0038677115 scopus 로고    scopus 로고
    • Noninvasive antepartum recording of fetal S-T segment with a newly developed 151-channel magnetic sensor system
    • Lowery CL, Campbell JQ, Wilson JD et al. Noninvasive antepartum recording of fetal S-T segment with a newly developed 151-channel magnetic sensor system. Am J Obstet Gynecol 2003; 188: 1491-7.
    • (2003) Am J Obstet Gynecol , vol.188 , pp. 1491-1497
    • Lowery, C.L.1    Campbell, J.Q.2    Wilson, J.D.3
  • 14
    • 0036876929 scopus 로고    scopus 로고
    • Multicentre study of fetal cardiac time intervals using magnetocardiography
    • Stinstra J, Golbach E, van Leeuwen P et al. Multicentre study of fetal cardiac time intervals using magnetocardiography. Br J Obstr Gynecol 2002; 109: 1235-43.
    • (2002) Br J Obstr Gynecol , vol.109 , pp. 1235-1243
    • Stinstra, J.1    Golbach, E.2    Van Leeuwen, P.3
  • 15
    • 0344011689 scopus 로고    scopus 로고
    • Changes in the frequency power spectrum of fetal heart rate in the course of pregnancy
    • Van Leeuwen P, Geue D, Lange S, Hatzmann W, Gronemeyer D. Changes in the frequency power spectrum of fetal heart rate in the course of pregnancy. Prenat Diagn 2003; 23: 909-16.
    • (2003) Prenat Diagn , vol.23 , pp. 909-916
    • Van Leeuwen, P.1    Geue, D.2    Lange, S.3    Hatzmann, W.4    Gronemeyer, D.5
  • 16
    • 2642568537 scopus 로고    scopus 로고
    • Dependency of magnetocardiographically determined fetal cardiac time intervals on gestational age, gender and postnatal biometrics in healthy pregnancies
    • Van Leeuwen P, Lange S, Klein A, Geue D, Gronemeyer DH. Dependency of magnetocardiographically determined fetal cardiac time intervals on gestational age, gender and postnatal biometrics in healthy pregnancies. BMC Pregnancy Childbirth 2004; 4: 6.
    • (2004) BMC Pregnancy Childbirth , vol.4 , pp. 6
    • Van Leeuwen, P.1    Lange, S.2    Klein, A.3    Geue, D.4    Gronemeyer, D.H.5
  • 18
    • 7044239496 scopus 로고    scopus 로고
    • Time course reconstruction of fetal cardiac signals from fMCG. Independent Component Analysis vs. Adaptive Maternal Beat Subtraction
    • Comani S, Mantini D, Lagatta A, Esposito F, Di Luzio S, Romani GL. Time course reconstruction of fetal cardiac signals from fMCG. Independent Component Analysis vs. Adaptive Maternal Beat Subtraction. Physiol Meas 2004; 25: 1305-21.
    • (2004) Physiol Meas , vol.25 , pp. 1305-1321
    • Comani, S.1    Mantini, D.2    Lagatta, A.3    Esposito, F.4    Di Luzio, S.5    Romani, G.L.6
  • 20
    • 0028416938 scopus 로고
    • Independent component analysis - A new concept?
    • Comon P. Independent component analysis - a new concept? Signal Processing 1994; 36: 287-314.
    • (1994) Signal Processing , vol.36 , pp. 287-314
    • Comon, P.1
  • 22
    • 0032629347 scopus 로고    scopus 로고
    • Fast and robust fixed-point algorithms for independent component analysis
    • Hyvärinen A. Fast and robust fixed-point algorithms for independent component analysis. IEEE Trans On Neural Networks 1999; 10: 626-34.
    • (1999) IEEE Trans on Neural Networks , vol.10 , pp. 626-634
    • Hyvärinen, A.1
  • 23
    • 2942730426 scopus 로고    scopus 로고
    • Fetal Tailoring of the Independent Component Analysis to multi-channel fMCG recordings for an optimal reconstruction of the fetal cardiac signal
    • Mantini D, Comani S, Pennesi P et al. Fetal Tailoring of the Independent Component Analysis to multi-channel fMCG recordings for an optimal reconstruction of the fetal cardiac signal. Biomed Tech 2004; 48: 186-8.
    • (2004) Biomed Tech , vol.48 , pp. 186-188
    • Mantini, D.1    Comani, S.2    Pennesi, P.3
  • 25
    • 12344278895 scopus 로고    scopus 로고
    • Fetal magnetocardiographic mapping using independent component analysis
    • Comani S, Mantini D, Alleva G, Di Luzio S, Romani GL. Fetal Magnetocardiographic Mapping using Independent Component Analysis. Physiol Meas 2004; 25: 1459-72.
    • (2004) Physiol Meas , vol.25 , pp. 1459-1472
    • Comani, S.1    Mantini, D.2    Alleva, G.3    Di Luzio, S.4    Romani, G.L.5
  • 27
    • 0031170244 scopus 로고    scopus 로고
    • Comparability of measurement results obtained with multi-SQUID-systems of different sensor configurations
    • Burghoff B, Steinhoff U, Haberkorn W, Koch H. Comparability of measurement results obtained with multi-SQUID-systems of different sensor configurations. IEEE Trans Appl Supercond 1997; 7: 3465-8.
    • (1997) IEEE Trans Appl Supercond , vol.7 , pp. 3465-3468
    • Burghoff, B.1    Steinhoff, U.2    Haberkorn, W.3    Koch, H.4
  • 28
    • 2342480548 scopus 로고    scopus 로고
    • Reproducibility and reliability of fetal cardiac time intervals using magnetocardiography
    • Van Leeuwen P, Lange S, Klein A et al. Reproducibility and reliability of fetal cardiac time intervals using magnetocardiography. Physiol Meas 2004; 25: 539-52.
    • (2004) Physiol Meas , vol.25 , pp. 539-552
    • Van Leeuwen, P.1    Lange, S.2    Klein, A.3
  • 29
    • 0034956556 scopus 로고    scopus 로고
    • A fetal Wolff-Parkinson-White syndrome diagnosed prenatally by magnetocardiography
    • Hosono T, Chiba Y, Shinto M, Kandori A, Tsukada K. A fetal Wolff-Parkinson-White syndrome diagnosed prenatally by magnetocardiography. Fetal Diagn Ther 2001; 16: 215-7.
    • (2001) Fetal Diagn Ther , vol.16 , pp. 215-217
    • Hosono, T.1    Chiba, Y.2    Shinto, M.3    Kandori, A.4    Tsukada, K.5
  • 30
    • 0347264743 scopus 로고    scopus 로고
    • Classifying cases of fetal Wolff-Parkinson-White syndrome by estimating the accessory pathway from fetal magnetocardiograms
    • Kandori A, Hosono T, Chiba Y et al. Classifying cases of fetal Wolff-Parkinson-White syndrome by estimating the accessory pathway from fetal magnetocardiograms. Med Biol Eng Comput 2003; 41: 33-9.
    • (2003) Med Biol Eng Comput , vol.41 , pp. 33-39
    • Kandori, A.1    Hosono, T.2    Chiba, Y.3
  • 31
    • 0037493625 scopus 로고    scopus 로고
    • Prenatal diagnosis of the Wolf-Parkinson-White syndrome by fetal magnetocardiography
    • Pirie AM, Wright J. Prenatal diagnosis of the Wolf-Parkinson-White syndrome by fetal magnetocardiography. Br J Obstr Gynecol 2003; 110: 710.
    • (2003) Br J Obstr Gynecol , vol.110 , pp. 710
    • Pirie, A.M.1    Wright, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.