메뉴 건너뛰기




Volumn 28, Issue SUPPL. 1, 2005, Pages

A new dual-chamber pacing mode to minimize ventricular pacing

Author keywords

Atrial pacing; Atrioventricular conduction; Dual chamber pacing; Sinus node dysfunction

Indexed keywords

ADULT; AGED; ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR BLOCK; ATRIOVENTRICULAR CONDUCTION; CARDIAC RESYNCHRONIZATION THERAPY; CLINICAL ARTICLE; CONFERENCE PAPER; DISEASE SEVERITY; ELECTROCARDIOGRAPHY; FEMALE; FOLLOW UP; HEART ATRIUM FIBRILLATION; HEART ATRIUM PACEMAKER; HEART ATRIUM PACING; HEART VENTRICLE PACING; HOSPITAL DISCHARGE; HUMAN; INCIDENCE; INTERMETHOD COMPARISON; LONG TERM CARE; MALE; SAFETY; SINUS NODE DYSFUNCTION; TREATMENT INDICATION; TREATMENT OUTCOME;

EID: 19944431778     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2005.00095.x     Document Type: Conference Paper
Times cited : (54)

References (12)
  • 1
    • 0031838335 scopus 로고    scopus 로고
    • Pacing in sick sinus syndrome - Need for a prospective, randomized trial comparing atrial with dual chamber pacing
    • Andersen HR, Nielsen JC. Pacing in sick sinus syndrome - Need for a prospective, randomized trial comparing atrial with dual chamber pacing. Pacing Clin Electrophysiol 1998; 21:1175-1179.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 1175-1179
    • Andersen, H.R.1    Nielsen, J.C.2
  • 2
    • 0038311033 scopus 로고    scopus 로고
    • Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction
    • Sweeney MO, Hellkamp AS, Ellenbogen KA, et al. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation 2003; 107:2932-2937.
    • (2003) Circulation , vol.107 , pp. 2932-2937
    • Sweeney, M.O.1    Hellkamp, A.S.2    Ellenbogen, K.A.3
  • 3
    • 0042354585 scopus 로고    scopus 로고
    • A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: Echocardiographic and clinical outcome
    • Nielsen JC, Kristensen L, Andersen HR, et al. A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: Echocardiographic and clinical outcome. J Am Coll Cardiol 2003; 42:614-623.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 614-623
    • Nielsen, J.C.1    Kristensen, L.2    Andersen, H.R.3
  • 4
    • 0027225880 scopus 로고
    • Chronic atrial fibrillation and stroke in paced patients with sick sinus syndrome. Relevance of clinical characteristics and pacing modalities
    • Sgarbossa EB, Pinski SL, Maloney JD, et al. Chronic atrial fibrillation and stroke in paced patients with sick sinus syndrome. Relevance of clinical characteristics and pacing modalities. Circulation 1993; 88:1045-1053.
    • (1993) Circulation , vol.88 , pp. 1045-1053
    • Sgarbossa, E.B.1    Pinski, S.L.2    Maloney, J.D.3
  • 5
    • 0031586473 scopus 로고    scopus 로고
    • Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome
    • Andersen HR, Nielsen JC, Thomsen PE, et al. Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome. Lancet 1997; 350:1210-1216.
    • (1997) Lancet , vol.350 , pp. 1210-1216
    • Andersen, H.R.1    Nielsen, J.C.2    Thomsen, P.E.3
  • 6
    • 0023690491 scopus 로고
    • Long-term pacing in sinus node disease: Effects of stimulation mode on cardiovascular morbidity and mortality
    • Rosenqvist M, Brandt J, Schüller H. Long-term pacing in sinus node disease: Effects of stimulation mode on cardiovascular morbidity and mortality. Am Heart J 1988; 116:16-22.
    • (1988) Am Heart J , vol.116 , pp. 16-22
    • Rosenqvist, M.1    Brandt, J.2    Schüller, H.3
  • 7
    • 4143116557 scopus 로고    scopus 로고
    • Selecting the appropriate pacing mode for patients with sick sinus syndrome: Evidence from randomized clinical trials
    • Albertsen AE, Nielsen JC. Selecting the appropriate pacing mode for patients with sick sinus syndrome: Evidence from randomized clinical trials. Card Electrophysiol Rev 2003; 7:406-410.
    • (2003) Card Electrophysiol Rev , vol.7 , pp. 406-410
    • Albertsen, A.E.1    Nielsen, J.C.2
  • 8
    • 0026734206 scopus 로고
    • Deleterious effects of long-term single-chamber ventricular pacing in patients with sick sinus syndrome: The hidden benefits of dual-chamber pacing
    • Hesselson AB, Parsonnet V, Bernstein AD, et al. Deleterious effects of long-term single-chamber ventricular pacing in patients with sick sinus syndrome: The hidden benefits of dual-chamber pacing. J Am Coll Cardiol 1992; 19:1542-1549.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 1542-1549
    • Hesselson, A.B.1    Parsonnet, V.2    Bernstein, A.D.3
  • 9
    • 0033108060 scopus 로고    scopus 로고
    • Programming a fixed long atrioventricular delay is not effective in preventing ventricular pacing in patients with sick sinus syndrome
    • Nielsen JC, Pedersen AK, Mortensen PT, et al. Programming a fixed long atrioventricular delay is not effective in preventing ventricular pacing in patients with sick sinus syndrome. Europace 1999; 2:113-120.
    • (1999) Europace , vol.2 , pp. 113-120
    • Nielsen, J.C.1    Pedersen, A.K.2    Mortensen, P.T.3
  • 10
    • 0035174841 scopus 로고    scopus 로고
    • AAIR versus DDDR pacing in the bradycardia tachycardia syndrome: A prospective, randomized, double-blind, crossover trial
    • Schwaab B, Kindermann M, Schätzer-Klotz D, et al. AAIR versus DDDR pacing in the bradycardia tachycardia syndrome: A prospective, randomized, double-blind, crossover trial. Pacing Clin Electrophysiol 2001; 24:1585-1595.
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 1585-1595
    • Schwaab, B.1    Kindermann, M.2    Schätzer-Klotz, D.3
  • 11
    • 0025644732 scopus 로고
    • Improved dual chamber pacing mode in paroxysmal atrioventricular conduction disorders
    • Girodo S, Ritter P, Pioger G, et al. Improved dual chamber pacing mode in paroxysmal atrioventricular conduction disorders. Pacing Clin Electrophysiol 1990; 13(Pt II):2059-2064.
    • (1990) Pacing Clin Electrophysiol , vol.13 , Issue.2 PART , pp. 2059-2064
    • Girodo, S.1    Ritter, P.2    Pioger, G.3
  • 12
    • 12844287801 scopus 로고    scopus 로고
    • Value of DDD/AMC mode in facilitating native AV conduction in patients implanted with dual-chamber pacemakers
    • abstract
    • Kaye G, Kraemer L, Mal R, et al. Value of DDD/AMC mode in facilitating native AV conduction in patients implanted with dual-chamber pacemakers. (abstract) Pacing Clin Electrophysiol 1999; 22(Pt II):159.
    • (1999) Pacing Clin Electrophysiol , vol.22 , Issue.2 PART , pp. 159
    • Kaye, G.1    Kraemer, L.2    Mal, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.