메뉴 건너뛰기




Volumn 4, Issue , 2003, Pages 2442-2446

A high-throughput whole-body PET scanner using flat panel PS-PMTs

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; FOURIER TRANSFORMS; MEDICAL IMAGING; PERSONAL COMPUTERS; PHOTOMULTIPLIERS; SENSITIVITY ANALYSIS; THROUGHPUT;

EID: 19944426584     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (7)

References (10)
  • 2
    • 0142210212 scopus 로고    scopus 로고
    • First time measurement of transaxial resolution for a new high-sensitivity PET prototype using 5 LSO panel detectors
    • W. F. Jones, J. Reed et al, "First time measurement of transaxial resolution for a new high-sensitivity PET prototype using 5 LSO panel detectors", IEEE Nucl Imag. Conf. Rec., 2002.
    • (2002) IEEE Nucl Imag. Conf. Rec.
    • Jones, W.F.1    Reed, J.2
  • 3
    • 0036731951 scopus 로고    scopus 로고
    • Optimization of injected dose based on noise equivalent count rate for 2- And 3-dimentional whole-body PET
    • C. Lartizien, C. Comtat et al, "Optimization of injected dose based on noise equivalent count rate for 2- and 3-dimentional whole-body PET", J. Nucl. Med. vol.43, pp.1268-1278, 2002.
    • (2002) J. Nucl. Med. , vol.43 , pp. 1268-1278
    • Lartizien, C.1    Comtat, C.2
  • 4
    • 0036816760 scopus 로고    scopus 로고
    • A Monte Carlo simulation study on coarse septa for scatter correction in 3-D PET
    • T. Hasegawa, E. Tanaka et al, "A Monte Carlo simulation study on coarse septa for scatter correction in 3-D PET", IEEE Trans. Nucl Sci. vol.49, pp.2133-2138, 2002.
    • (2002) IEEE Trans. Nucl Sci. , vol.49 , pp. 2133-2138
    • Hasegawa, T.1    Tanaka, E.2
  • 6
    • 0142167986 scopus 로고    scopus 로고
    • Performance of a PET detector with a 256ch flat panel PS-PMT
    • N. Inadama, H. Murayama et al, "Performance of a PET detector with a 256ch flat panel PS-PMT", IEEE Nucl. Imag. Conf. Rec., 2002.
    • (2002) IEEE Nucl. Imag. Conf. Rec.
    • Inadama, N.1    Murayama, H.2
  • 7
    • 0030082270 scopus 로고    scopus 로고
    • Adaptive segmented attenuation correction for whole-body PET imaging
    • M. Xu, P.D. Cutler and W.K. Luk, "Adaptive segmented attenuation correction for whole-body PET imaging," IEEE Trans. Nucl. Sci., vol.43, pp.331-336, 1996.
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , pp. 331-336
    • Xu, M.1    Cutler, P.D.2    Luk, W.K.3
  • 8
    • 0003376263 scopus 로고
    • A factorization method for the 3D x-ray transform
    • M. Defrise, "A factorization method for the 3D x-ray transform," Inverse Problems, vol. 11, pp.983-994, 1995.
    • (1995) Inverse Problems , vol.11 , pp. 983-994
    • Defrise, M.1
  • 9
    • 0038458982 scopus 로고    scopus 로고
    • Subset-dependent relaxation in block-iterative algorithms for image reconstruction in emission tomography
    • E. Tanaka and H. Kudo, "Subset-dependent relaxation in block-iterative algorithms for image reconstruction in emission tomography", Phys. Med. Biol. vol.48, pp. 1405-1422, 2003.
    • (2003) Phys. Med. Biol. , vol.48 , pp. 1405-1422
    • Tanaka, E.1    Kudo, H.2
  • 10
    • 11844268605 scopus 로고    scopus 로고
    • Data correction and normalization for a new PET scanner having coarse septa
    • will be submitted to
    • K. Ote, M. Takahashi et al, "Data correction and normalization for a new PET scanner having coarse septa", will be submitted to IEEE NSS/MIC 2003.
    • IEEE NSS/MIC 2003
    • Ote, K.1    Takahashi, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.