메뉴 건너뛰기




Volumn 52, Issue 4, 2005, Pages 379-382

The Stealth Station™ Image Guidance System may interfere with pulse oximetry

Author keywords

[No Author keywords available]

Indexed keywords

HEMOGLOBIN;

EID: 19944398474     PISSN: 0832610X     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03016280     Document Type: Article
Times cited : (17)

References (10)
  • 1
    • 0033051353 scopus 로고    scopus 로고
    • Pulse oximetry
    • Jubran A. Pulse oximetry. Crit Care 1999; 3: R11-7.
    • (1999) Crit. Care , vol.3
    • Jubran, A.1
  • 2
    • 0028469070 scopus 로고
    • The NeuroStation™-a highly accurate, minimally invasive solution to frameless stereotactic neurosurgery
    • Smith KR, Frank KJ, Bucholz RD. The NeuroStation™-a highly accurate, minimally invasive solution to frameless stereotactic neurosurgery. Comput Med Imaging Graph 1994; 18: 247-56.
    • (1994) Comput. Med. Imaging Graph , vol.18 , pp. 247-256
    • Smith, K.R.1    Frank, K.J.2    Bucholz, R.D.3
  • 3
    • 0036138074 scopus 로고    scopus 로고
    • Issues in the laboratory evaluation of pulse oximeter performance
    • Jopling MW, Mannheimer PD, Bebout DE. Issues in the laboratory evaluation of pulse oximeter performance. Anesth Analg 2002; 94(1 Suppl): S62-8.
    • (2002) Anesth. Analg. , vol.94 , Issue.1 SUPPL.
    • Jopling, M.W.1    Mannheimer, P.D.2    Bebout, D.E.3
  • 5
    • 0030989206 scopus 로고    scopus 로고
    • Effects of motion, ambient light, and hypoperfusion on pulse oximeter function
    • Trivedi NS, Ghouri AT, Shah NK, Lai E, Barker SJ. Effects of motion, ambient light, and hypoperfusion on pulse oximeter function. J Clin Anesth 1997; 9: 179-83.
    • (1997) J. Clin. Anesth. , vol.9 , pp. 179-183
    • Trivedi, N.S.1    Ghouri, A.T.2    Shah, N.K.3    Lai, E.4    Barker, S.J.5
  • 6
    • 0022511724 scopus 로고
    • Minimizing interference and false alarms from electrocautery in the Nellcor N-100 pulse oximeter
    • Block FE Jr, Detko GJ Jr. Minimizing interference and false alarms from electrocautery in the Nellcor N-100 pulse oximeter. J Clin Monit 1986; 2: 203-5.
    • (1986) J. Clin. Monit. , vol.2 , pp. 203-205
    • Block Jr., F.E.1    Detko Jr., G.J.2
  • 7
    • 0024586470 scopus 로고
    • Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry
    • Barker SJ, Tremper KK, Hyatt J. Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry. Anesthesiology 1989; 70: 112-7.
    • (1989) Anesthesiology , vol.70 , pp. 112-117
    • Barker, S.J.1    Tremper, K.K.2    Hyatt, J.3
  • 9
    • 0026100834 scopus 로고
    • Potential errors in pulse oximetry. III: Effects of interferences, dyes, dyshaemoglobins and other pigments
    • Ralston AC, Webb RK, Runciman WB. Potential errors in pulse oximetry. III: effects of interferences, dyes, dyshaemoglobins and other pigments. Anaesthesia 1991; 46: 291-5.
    • (1991) Anaesthesia , vol.46 , pp. 291-295
    • Ralston, A.C.1    Webb, R.K.2    Runciman, W.B.3
  • 10
    • 0001065389 scopus 로고    scopus 로고
    • Noninvasive optical monitoring
    • Bronzino JD (Ed.). 2nd ed. Boca Raton, Florida: CRC Press
    • Flewelling R. Noninvasive optical monitoring. In: Bronzino JD (Ed.). IEEE Biomedical Engineering Handbook, volume I, 2nd ed. Boca Raton, Florida: CRC Press; 1999: 86-5.
    • (1999) IEEE Biomedical Engineering Handbook , vol.1 , pp. 86-95
    • Flewelling, R.1