-
1
-
-
19744374461
-
Precise magnetic sensors and magnetometers for military and space applications
-
A. Cerman, P. Ripka, P. Kašpar, A. Tipek, and A. platil Precise magnetic sensors and magnetometers for military and space applications Sens. Transducers 38 12 2003 54 58
-
(2003)
Sens. Transducers
, vol.38
, Issue.12
, pp. 54-58
-
-
Cerman, A.1
Ripka, P.2
Kašpar, P.3
Tipek, A.4
Platil, A.5
-
3
-
-
19744367274
-
Improvement of AMR magnetometer precision
-
Eurosensors XVI, Prague
-
A. Platil, M. Vopálenský, P. Ripka, P. Kašpar, Improvement of AMR Magnetometer Precision, Eurosensors XVI, Prague, Book of Abstracts Part 2, 2002, pp. 339-340.
-
(2002)
Book of Abstracts Part 2
, pp. 339-340
-
-
Platil, A.1
Vopálenský, M.2
Ripka, P.3
Kašpar, P.4
-
4
-
-
0033280652
-
A 2-D CMOS microfluxgate sensor system for digital detection of weak magnetic fields
-
S. Kawahito, Ch. Maier, M. Schneider, M. Zimmermann, and H. Baltes A 2-D CMOS microfluxgate sensor system for digital detection of weak magnetic fields IEEE J. Solid-State Circuits 34 1999 1843 1851
-
(1999)
IEEE J. Solid-State Circuits
, vol.34
, pp. 1843-1851
-
-
Kawahito, S.1
Maier, Ch.2
Schneider, M.3
Zimmermann, M.4
Baltes, H.5
-
5
-
-
0001376383
-
Concept and first results of a digital fluxgate magnetometer
-
H.U. Auster, A. Lichopoj, J. Rustenbach, H. Bitterlich, K.H. Fornacon, O. Hillenmaier, R. Krause, H.J. Schenk, and V. Auster Concept and first results of a digital fluxgate magnetometer Meas. Sci. Technol. 6 1995 477 481
-
(1995)
Meas. Sci. Technol.
, vol.6
, pp. 477-481
-
-
Auster, H.U.1
Lichopoj, A.2
Rustenbach, J.3
Bitterlich, H.4
Fornacon, K.H.5
Hillenmaier, O.6
Krause, R.7
Schenk, H.J.8
Auster, V.9
-
6
-
-
0033293593
-
Digital fluxgate magnetometer for the Astrid-2 Satellite
-
E.B. Pedersen Digital fluxgate magnetometer for the Astrid-2 Satellite Meas. Sci. Technol. 10 1999 N124 N129
-
(1999)
Meas. Sci. Technol.
, vol.10
-
-
Pedersen, E.B.1
-
9
-
-
0041844488
-
How to Get 23 bits of effective resolution from Your 24-bit converter
-
Burr-Brown, USA
-
B.C. Baker, How to Get 23 bits of effective resolution from Your 24-bit converter, Application Bulletin AB120, Burr-Brown, USA, 1997
-
(1997)
Application Bulletin AB120
-
-
Baker, B.C.1
-
10
-
-
19744380713
-
Testing of the high-resolution converters ADS1211 and AD7714
-
A. Cerman, and P. Ripka Testing of the high-resolution converters ADS1211 and AD7714 Baltic Electr. Conf. 2000 315 316 Tallinn, Estonia
-
(2000)
Baltic Electr. Conf.
, pp. 315-316
-
-
Cerman, A.1
Ripka, P.2
-
13
-
-
0037311132
-
A weak magnetic field measurement system using micro-fluxgate sensors and delta-sigma interface
-
S. Kawahito, A. Cerman, K. Aramaki, and Y. Tadokoro: A weak magnetic field measurement system using micro-fluxgate sensors and delta-sigma interface IEEE Trans. Inst. Meas. 25 1 2003 103 110
-
(2003)
IEEE Trans. Inst. Meas.
, vol.25
, Issue.1
, pp. 103-110
-
-
Kawahito, S.1
Cerman, A.2
Aramaki, K.3
Tadokoro, Y.4
-
14
-
-
19744372662
-
Delta-sigma modulator in the sensor feedback loop
-
Guimaraes, Portugal
-
A. Cerman, A. Kuna, P. Ripka, Delta-sigma modulator in the sensor feedback loop, Eurosensors XVII, Guimaraes, Portugal, 2003, pp. 677-678.
-
(2003)
Eurosensors XVII
, pp. 677-678
-
-
Cerman, A.1
Kuna, A.2
Ripka, P.3
-
15
-
-
0038335294
-
A sigma-delta fluxgate magnetometer for space applications
-
W. Magnes A sigma-delta fluxgate magnetometer for space applications Meas. Sci. Technol. 14 2003 1003 1012
-
(2003)
Meas. Sci. Technol.
, vol.14
, pp. 1003-1012
-
-
Magnes, W.1
-
16
-
-
19744375402
-
-
Poster, Prague
-
A. Tipek, A. Cerman, P. Ripka, The new method of the sampling in the satellite magnetometer, Poster, Prague, 2000, pp. E29.
-
(2000)
The New Method of the Sampling in the Satellite Magnetometer
-
-
Tipek, A.1
Cerman, A.2
Ripka, P.3
|