메뉴 건너뛰기




Volumn 13, Issue 3, 2005, Pages 135-137

Introduction to high-speed imaging of the larynx

Author keywords

[No Author keywords available]

Indexed keywords

CAMERA; DIAGNOSTIC IMAGING; EDITORIAL; HIGH SPEED IMAGING; IMAGING SYSTEM; LARYNX; PRIORITY JOURNAL; VIDEOKYMOGRAPHY; VIDEOTROBOSCOPY; VOCAL CORD;

EID: 19644380899     PISSN: 10689508     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.moo.0000162262.26868.df     Document Type: Editorial
Times cited : (15)

References (16)
  • 1
    • 0038654420 scopus 로고    scopus 로고
    • An automatic method to quantify the vibration properties of human vocal folds via videokymography
    • Qui Q, Schutte HK, Gu L, Yu Q. An automatic method to quantify the vibration properties of human vocal folds via videokymography. Folia Phoniatr Logop 2003; 55:128-136.
    • (2003) Folia Phoniatr Logop , vol.55 , pp. 128-136
    • Qui, Q.1    Schutte, H.K.2    Gu, L.3    Yu, Q.4
  • 2
    • 0033813334 scopus 로고    scopus 로고
    • Quantitative study of mucosal wave via videokymography in canine larynges
    • Jiang JJ, Chang CIB, Raviv JR, et al. Quantitative study of mucosal wave via videokymography in canine larynges. Laryngoscope 2000; 110:1567-1573.
    • (2000) Laryngoscope , vol.110 , pp. 1567-1573
    • Jiang, J.J.1    Chang, C.I.B.2    Raviv, J.R.3
  • 3
    • 0033800481 scopus 로고    scopus 로고
    • Functional imaging of vocal fold vibration: Digital multislice high-speed kymography
    • Whittenberg R, Tigges M, Mergell P, Eysholdt U. Functional imaging of vocal fold vibration: digital multislice high-speed kymography. J Voice 2000; 14:422-442.
    • (2000) J Voice , vol.14 , pp. 422-442
    • Whittenberg, R.1    Tigges, M.2    Mergell, P.3    Eysholdt, U.4
  • 5
    • 0033638770 scopus 로고    scopus 로고
    • Vocal fold vibrations: High-speed imaging, kymograhy, and acoustic analysis: A preliminary report
    • Larsson H, Hertegard S, Lindestad PA, Hammarberg B. Vocal fold vibrations: high-speed imaging, kymograhy, and acoustic analysis: a preliminary report. Laryngoscope 2000; 110:2117-2122.
    • (2000) Laryngoscope , vol.110 , pp. 2117-2122
    • Larsson, H.1    Hertegard, S.2    Lindestad, P.A.3    Hammarberg, B.4
  • 6
    • 0029991874 scopus 로고    scopus 로고
    • Videokymography: High-speed line scanning of vocal fold vibration
    • Svec JG, Schutte HK. Videokymography: high-speed line scanning of vocal fold vibration. J Voice 1996; 10:201-205.
    • (1996) J Voice , vol.10 , pp. 201-205
    • Svec, J.G.1    Schutte, H.K.2
  • 8
    • 0027275293 scopus 로고
    • High-speed, light intensified digital imaging of vocal fold vibrations in high optical resolution via indirect microlaryngoscopy
    • Hess MM, Gross M. High-speed, light intensified digital imaging of vocal fold vibrations in high optical resolution via indirect microlaryngoscopy. Ann Otol Rhinol Laryngol 1993; 102:502-507.
    • (1993) Ann Otol Rhinol Laryngol , vol.102 , pp. 502-507
    • Hess, M.M.1    Gross, M.2
  • 10
    • 0029199744 scopus 로고
    • Vocal fold vibration patterns and modes of phonation
    • Sundberg J. Vocal fold vibration patterns and modes of phonation. Folia Phoniatr Logop 1995; 47:218-228.
    • (1995) Folia Phoniatr Logop , vol.47 , pp. 218-228
    • Sundberg, J.1
  • 11
    • 0035174891 scopus 로고    scopus 로고
    • High-speed digital imaging of the medial surface of the vocal folds
    • Berry DA, Montequin DW, Tayama N. High-speed digital imaging of the medial surface of the vocal folds. J Acoust Soc Am 2001; 110:2539-2547.
    • (2001) J Acoust Soc Am , vol.110 , pp. 2539-2547
    • Berry, D.A.1    Montequin, D.W.2    Tayama, N.3
  • 12
    • 0038713716 scopus 로고    scopus 로고
    • Normal voice production: Computation of driving parameters from endoscopic digital high speed images
    • Dollinger M, Braunschweig T, Lohscheller J, et al. Normal Voice Production: Computation of Driving Parameters from Endoscopic Digital High Speed Images. Methods Inf Med 2003; 42:271-276.
    • (2003) Methods Inf Med , vol.42 , pp. 271-276
    • Dollinger, M.1    Braunschweig, T.2    Lohscheller, J.3
  • 13
    • 0035215922 scopus 로고    scopus 로고
    • A method of applying fourier analysis to high-speed laryngoscopy
    • Granqvist S, Lindestad PA. A method of applying fourier analysis to high-speed laryngoscopy. J Acoust Soc Am 2001; 110:3193-3197.
    • (2001) J Acoust Soc Am , vol.110 , pp. 3193-3197
    • Granqvist, S.1    Lindestad, P.A.2
  • 14
    • 0030465350 scopus 로고    scopus 로고
    • High-speed imaging of vocal fold vibrations and larynx movements with vocalizations of different vowels
    • Maurer D, Hess M, Gross M. High-Speed imaging of vocal fold vibrations and larynx movements with vocalizations of different vowels. Ann Otol Rhinol Laryngol 1996; 105:975-981.
    • (1996) Ann Otol Rhinol Laryngol , vol.105 , pp. 975-981
    • Maurer, D.1    Hess, M.2    Gross, M.3
  • 15
    • 0036276343 scopus 로고    scopus 로고
    • High-precision measurement of the vocal fold length and vibratory amplitudes
    • Schuberth S, Hoppe U, Dollinger M, et al. High-precision measurement of the vocal fold length and vibratory amplitudes. Laryngoscope 2002; 112:1043-1049.
    • (2002) Laryngoscope , vol.112 , pp. 1043-1049
    • Schuberth, S.1    Hoppe, U.2    Dollinger, M.3
  • 16
    • 0034828071 scopus 로고    scopus 로고
    • Deviant vocal fold vibration as observed during videokymography: The effect on voice quality
    • Verdonck-de Leeuw IM, Festen JM, Mahieu H. Deviant vocal fold vibration as observed during videokymography: the effect on voice quality. J Voice 2001; 15:313-322.
    • (2001) J Voice , vol.15 , pp. 313-322
    • Verdonck-De Leeuw, I.M.1    Festen, J.M.2    Mahieu, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.