메뉴 건너뛰기




Volumn 1, Issue , 1998, Pages 878-883

Control of a three-phase active power filter with optimized design of the energy storage capacitor

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVE POWER FILTER; CONTROL SCHEMES; DC VOLTAGE; ENERGY STORAGE CAPACITOR; OPTIMIZED DESIGNS; REAL POWER BALANCE; SHUNT ACTIVE POWER FILTERS;

EID: 19644364441     PISSN: 02759306     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PESC.1998.702003     Document Type: Conference Paper
Times cited : (22)

References (9)
  • 1
    • 0028423793 scopus 로고
    • Trends in active power line conditioners
    • May
    • H. AKAGI, "Trends in Active Power line Conditioners", IEEE Trans, on Power Elect., vol. 9, no. 3, May 1994, pp 263-268
    • (1994) IEEE Trans, on Power Elect , vol.9 , Issue.3 , pp. 263-268
    • Akagi, H.1
  • 2
    • 72949097144 scopus 로고
    • A series active power filter which compensates current harmonics and voltage unbalance simultaneously
    • L. MORAN, P. WERLINGER, J. DIXON, R. WALLACE, "A Series active power filter which compensates current harmonics and voltage Unbalance simultaneously", Proc. IEEE/PESC, pp. 222-227, 1995
    • (1995) Proc. IEEE/PESC , pp. 222-227
    • Moran, L.1    Werlinger, P.2    Dixon, J.3    Wallace, R.4
  • 3
    • 0021429788 scopus 로고
    • Instantaneous reactive power compensators comprising switching devices without energy storage components
    • May/June
    • H. AKAGI, Y. KANAZAWA & A. NABAE. "Instantaneous reactive power compensators comprising switching devices without energy storage components", IEEE Trans, on Ind. Appl., Vol. IA-20, No3, May/June 1984, pp. 625-630
    • (1984) IEEE Trans, on Ind. Appl , vol.IA-20 , Issue.3 , pp. 625-630
    • Akagi, H.1    Kanazawa, Y.2    Nabae, A.3
  • 4
    • 38249001741 scopus 로고
    • Reactive and harmonic current compensation for unbalanced three-phase systems using the synchronous detection method
    • C. L. CHEN, C. E. LIN and C. L. HUANG, "Reactive and harmonic current compensation for unbalanced three-phase systems using the synchronous detection method", Electric Power System Research, No. 26, 1993, pp. 163-170
    • (1993) Electric Power System Research , Issue.26 , pp. 163-170
    • Chen, C.L.1    Lin, C.E.2    Huang, C.L.3
  • 5
    • 0029407723 scopus 로고    scopus 로고
    • Performance comparison of the three-phase active-power-filter algorithms
    • November
    • H.-L. JOU, "Performance comparison of the three-phase active-power-filter algorithms", IEE Proc.-Gener. Transm. Distrib., Vol. 142, No. 6, November pp 646-652
    • IEE Proc.-Gener. Transm. Distrib , vol.142 , Issue.6 , pp. 646-652
    • Jou, H.-L.1
  • 6
    • 0030143512 scopus 로고    scopus 로고
    • Simplified control method for the single-phase active power filter
    • May
    • J.-C. WU, H.-LJOU, "Simplified control method for the Single-phase active power filter", DEE Proc.-Electr. Power Appl., Vol. 143, No. 3, May pp 219-224
    • DEE Proc.-Electr. Power Appl , vol.143 , Issue.3 , pp. 219-224
    • Wu, J.-C.1    Jou H.-L2
  • 8
    • 43049163686 scopus 로고
    • Automatique, commande des systemes lineaires
    • ISBN 2-86601-359-X
    • P. DE LARMINAT, "Automatique, commande des systemes lineaires", Hermes, ISBN 2-86601-359-X, 1993
    • (1993) Hermes
    • De Larminat, P.1
  • 9
    • 0030643536 scopus 로고    scopus 로고
    • Operation of a phase locked loop system under distorted utility conditions
    • January/February
    • V. KAURA, V. BLASKO, "Operation of a Phase Locked Loop System Under Distorted Utility Conditions", IEEE Transactions On Industry Applications, Vol. 33, NO. 1, January/February 1997.
    • (1997) IEEE Transactions on Industry Applications , vol.33 , Issue.1
    • Kaura, V.1    Blasko, V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.