메뉴 건너뛰기




Volumn 26, Issue 3, 2005, Pages 260-265

Reproducibility of transpulmonary thermodilution measurements in patients with burn shock and hypothermia

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; ARTIFICIAL VENTILATION; BLOOD VOLUME; BURN SHOCK; CLINICAL TRIAL; COEFFICIENT OF VARIATION; CORE TEMPERATURE; CORRELATION ANALYSIS; CORRELATION OF VARIATION; FEMALE; FIBER OPTICS; HEART INDEX; HEART OUTPUT; HEMODYNAMIC PARAMETERS; HUMAN; HYPOTHERMIA; INTEGRATED FIBEROPTIC MONITORING SYSTEM; INTENSIVE CARE; INTRATHORACIC BLOOD VOLUME INDEX; LUNG EXTRAVASCULAR FLUID; LUNG EXTRAVASCULAR FLUID INDEX; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; MONITORING; REPRODUCIBILITY; STATISTICAL PARAMETERS; THERMAL INJURY; THERMODILUTION; THORAX; THORAX BLOOD VOLUME; TRANSPULMONARY THERMODILUTION; UNIVERSITY HOSPITAL;

EID: 19544370366     PISSN: 02738481     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.BCR.0000162156.26517.E4     Document Type: Article
Times cited : (35)

References (19)
  • 1
    • 0014413903 scopus 로고
    • Physiological response to crystalloid resuscitation of severe burns
    • Baxter CR, Shires GT. Physiological response to crystalloid resuscitation of severe burns. Ann NY Acad Sci 1968;150: 874-9.
    • (1968) Ann NY Acad Sci , vol.150 , pp. 874-879
    • Baxter, C.R.1    Shires, G.T.2
  • 2
    • 0025852141 scopus 로고
    • Adequate resuscitation of burn patients may not be measured by urine output and vital signs
    • Dries DJ, Waxman K. Adequate resuscitation of burn patients may not be measured by urine output and vital signs. Crit Care Med 1991;19:327-9.
    • (1991) Crit Care Med , vol.19 , pp. 327-329
    • Dries, D.J.1    Waxman, K.2
  • 3
    • 0034124259 scopus 로고    scopus 로고
    • Burn shock resuscitation: Tradition or evidence-based medicine?
    • Holm C. Burn shock resuscitation: tradition or evidence-based medicine? Resuscitation 2000;44:157-64.
    • (2000) Resuscitation , vol.44 , pp. 157-164
    • Holm, C.1
  • 5
    • 0028868350 scopus 로고
    • Survival in major burn injuries is predicted by early response to SwanGanz guided resuscitation
    • Schiller WR, Bay RC, McLachlan JG,Sagraves SG. Survival in major burn injuries is predicted by early response to SwanGanz guided resuscitation. Am J Surg 1995;170:696-700.
    • (1995) Am J Surg , vol.170 , pp. 696-700
    • Schiller, W.R.1    Bay, R.C.2    McLachlan, J.G.3    Sagraves, S.G.4
  • 6
    • 0031020699 scopus 로고    scopus 로고
    • Resuscitation of thermally injured patients with oxygen transport criteria as goals of therapy
    • Barton RG, Saffle JR, Morris SE, Mone M, et al. Resuscitation of thermally injured patients with oxygen transport criteria as goals of therapy. J Burn Care Rehabil 1997;1997; 18:1-9.
    • (1997) J Burn Care Rehabil 1997 , vol.18 , pp. 1-9
    • Barton, R.G.1    Saffle, J.R.2    Morris, S.E.3    Mone, M.4
  • 7
    • 0033995808 scopus 로고    scopus 로고
    • Intrathoracic blood volume as endpoint for burn shock resuscitation: An observational study of 24 patients
    • Holm C, Melcer B, Hörbrand F, Wörl HH, Henckel von Donnersmarck G, Mühlbauer W. Intrathoracic blood volume as endpoint for burn shock resuscitation: an observational study of 24 patients. J Trauma 2000;48:728-34.
    • (2000) J Trauma , vol.48 , pp. 728-734
    • Holm, C.1    Melcer, B.2    Hörbrand, F.3    Wörl, H.H.4    Von Henckel Donnersmarck, G.5    Mühlbauer, W.6
  • 8
    • 0031897323 scopus 로고    scopus 로고
    • Transpulmonary indicator dilution techniques in intensive care medicine
    • Spiegel TV, Hoeft A. Transpulmonary indicator dilution techniques in intensive care medicine. Anaesthesist 1998;47: 220-8.
    • (1998) Anaesthesist , vol.47 , pp. 220-228
    • Spiegel, T.V.1    Hoeft, A.2
  • 9
    • 0035137761 scopus 로고    scopus 로고
    • Arterial thermodilution: An alternative to pulmonary artery catheter for cardiac output assessment in burn patients
    • Holm C, Melcer B, Hörbrand F, Henckel von Donnersmarck G, Mühlbauer W. Arterial thermodilution: an alternative to pulmonary artery catheter for cardiac output assessment in burn patients. Burns 2001;27:161-6.
    • (2001) Burns , vol.27 , pp. 161-166
    • Holm, C.1    Melcer, B.2    Hörbrand, F.3    Von Henckel Donnersmarck, G.4    Mühlbauer, W.5
  • 10
    • 0018639392 scopus 로고
    • Thermodilution cardiac output: A critical analysis and review of the literature
    • Levett JM, Replogle RL. Thermodilution cardiac output: a critical analysis and review of the literature. J Surg Res 1979; 27:392-404.
    • (1979) J Surg Res , vol.27 , pp. 392-404
    • Levett, J.M.1    Replogle, R.L.2
  • 11
    • 0027447134 scopus 로고
    • Errors in the measurement of cardiac output by thermodilution
    • Nishikawa T, Dohi S. Errors in the measurement of cardiac output by thermodilution. Can J Anesth 1993;40:142-53.
    • (1993) Can J Anesth , vol.40 , pp. 142-153
    • Nishikawa, T.1    Dohi, S.2
  • 12
    • 0031979188 scopus 로고    scopus 로고
    • Reproducibility of double indicator dilution measurements of intrathoracic blood volume compartments, extravascular lung water and liver function
    • Goedje O, Peyerl M, Seebauer T, Dewald O, Reichart B. Reproducibility of double indicator dilution measurements of intrathoracic blood volume compartments, extravascular lung water and liver function. Chest 1998;113:1070-7.
    • (1998) Chest , vol.113 , pp. 1070-1077
    • Goedje, O.1    Peyerl, M.2    Seebauer, T.3    Dewald, O.4    Reichart, B.5
  • 13
    • 0026628714 scopus 로고
    • Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass
    • Bazaral MG, Petre J, Novoa R. Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass. Anaesthesiology 1992;77:31-7.
    • (1992) Anaesthesiology , vol.77 , pp. 31-37
    • Bazaral, M.G.1    Petre, J.2    Novoa, R.3
  • 14
    • 0030950844 scopus 로고    scopus 로고
    • Thermodilution cardiac output measurement during simultaneous volume infusion through the venous infusion port of the pulmonary artery catheter
    • Griffin K, Benjamin E, DelGiudice R, Schechter C, Iberti TJ. Thermodilution cardiac output measurement during simultaneous volume infusion through the venous infusion port of the pulmonary artery catheter. J Cardiothorac Vasc Anesth 1997;11:437-9.
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 437-439
    • Griffin, K.1    Benjamin, E.2    Delgiudice, R.3    Schechter, C.4    Iberti, T.J.5
  • 15
    • 0024787531 scopus 로고
    • Central venous blood temperature fluctuations and thermodilution signal processing in dogs
    • Johnson RW, Normann RA. Central venous blood temperature fluctuations and thermodilution signal processing in dogs. Ann Biomed Eng 1989;17:657-9.
    • (1989) Ann Biomed Eng , vol.17 , pp. 657-659
    • Johnson, R.W.1    Normann, R.A.2
  • 16
    • 0036079621 scopus 로고    scopus 로고
    • Pulmonary artery blood temperature and the measurement of cardiac output by thermodilution
    • Moise SF, Sinclair CJ, Scott DHT. Pulmonary artery blood temperature and the measurement of cardiac output by thermodilution. Anaesthesia 2002;57:562-6.
    • (2002) Anaesthesia , vol.57 , pp. 562-566
    • Moise, S.F.1    Sinclair, C.J.2    Scott, D.H.T.3
  • 17
    • 1542753652 scopus 로고    scopus 로고
    • Perioperative hypothermia in the high-risk surgical patient
    • Leslie K, Sessler DI. Perioperative hypothermia in the high-risk surgical patient. Best Pract Res Clin Anesthesiol 2003; 17:485-98.
    • (2003) Best Pract Res Clin Anesthesiol , vol.17 , pp. 485-498
    • Leslie, K.1    Sessler, D.I.2
  • 18
    • 0035661168 scopus 로고    scopus 로고
    • Thermoregulation: Anesthetic and perioperative concerns
    • Fiedler MA. Thermoregulation: anesthetic and perioperative concerns. AANA J 2001;69:485-91.
    • (2001) AANA J , vol.69 , pp. 485-491
    • Fiedler, M.A.1
  • 19
    • 0030753052 scopus 로고    scopus 로고
    • Infusion of hot crystalloid during operative wound debridement
    • Gore DC, Beaston J. Infusion of hot crystalloid during operative wound debridement. J Trauma 1997;42:1112-5.
    • (1997) J Trauma , vol.42 , pp. 1112-1115
    • Gore, D.C.1    Beaston, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.