메뉴 건너뛰기




Volumn 299, Issue 1-2, 2005, Pages 1-8

Piezoelectric immunoassay for complement C4 based on a Nafion-modified interface for antibody immobilization

Author keywords

Complement C4; Nafion; Piezoelectric immunosensor; Simple immobilization procedure

Indexed keywords

COMPLEMENT COMPONENT C4; IMMOBILIZED ANTIBODY; ION EXCHANGE RESIN; NAFION; POLYMER; SILICON DIOXIDE; UNCLASSIFIED DRUG;

EID: 19444378634     PISSN: 00221759     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jim.2004.11.004     Document Type: Article
Times cited : (15)

References (26)
  • 2
    • 33845184543 scopus 로고
    • Formation of monolayers by the coadsorption of thiols on gold: Variation in the head group, tail group, and solvent
    • C.D. Bain, J. Evall, and G.M. Whitesides Formation of monolayers by the coadsorption of thiols on gold: variation in the head group, tail group, and solvent J. Am. Chem. Soc. 111 1989 7155
    • (1989) J. Am. Chem. Soc. , vol.111 , pp. 7155
    • Bain, C.D.1    Evall, J.2    Whitesides, G.M.3
  • 3
    • 0035091495 scopus 로고    scopus 로고
    • Genetic, structural and functional diversities of human complement components C4A and C4B and their mouse homologues, Slp and C4
    • C.A. Blanchong, E.K. Chung, K.L. Rupert, Y. Yang, Z.Y. Yang, B. Zhou, J.M. Moulds, and C.Y. Yu Genetic, structural and functional diversities of human complement components C4A and C4B and their mouse homologues, Slp and C4 Int. Immunopharmacol. 1 2001 365
    • (2001) Int. Immunopharmacol. , vol.1 , pp. 365
    • Blanchong, C.A.1    Chung, E.K.2    Rupert, K.L.3    Yang, Y.4    Yang, Z.Y.5    Zhou, B.6    Moulds, J.M.7    Yu, C.Y.8
  • 4
    • 0031864341 scopus 로고    scopus 로고
    • The detection of Pseudomonas aeroginosa using the quartz crystal microbalance
    • J.S. Boveniser, M.B. Jacobs, G.G. Guilbault, and C.K. O'Sullivan The detection of Pseudomonas aeroginosa using the quartz crystal microbalance Anal. Lett. 31 1998 1287
    • (1998) Anal. Lett. , vol.31 , pp. 1287
    • Boveniser, J.S.1    Jacobs, M.B.2    Guilbault, G.G.3    O'Sullivan, C.K.4
  • 5
    • 0032145832 scopus 로고    scopus 로고
    • Piezoelectric quartz crystal biosensors-a review
    • R.L. Bunde, E.J. Jarvi, and J.J. Rosentreter Piezoelectric quartz crystal biosensors-a review Talanta 46 1998 1223
    • (1998) Talanta , vol.46 , pp. 1223
    • Bunde, R.L.1    Jarvi, E.J.2    Rosentreter, J.J.3
  • 6
    • 2342483741 scopus 로고    scopus 로고
    • A novel immunosensor based on self-assembled chitosan/alginate multilayers for the detection of factor B
    • T. Deng, H. Wang, J.S. Li, G.L. Shen, and R.Q. Yu A novel immunosensor based on self-assembled chitosan/alginate multilayers for the detection of factor B Sens. Actuators, B, Chem. 99 2004 123
    • (2004) Sens. Actuators, B, Chem. , vol.99 , pp. 123
    • Deng, T.1    Wang, H.2    Li, J.S.3    Shen, G.L.4    Yu, R.Q.5
  • 7
    • 0025127970 scopus 로고
    • Spontaneously formed functionally active avidin monolayers on metal surfaces: A strategy for immobilizing biological reagents and design of piezoelectric biosensors
    • R.C. Ebersole, J.A. Miller, J.R. Moran, and M.D. Ward Spontaneously formed functionally active avidin monolayers on metal surfaces: a strategy for immobilizing biological reagents and design of piezoelectric biosensors J. Am. Chem. Soc. 112 1990 3239
    • (1990) J. Am. Chem. Soc. , vol.112 , pp. 3239
    • Ebersole, R.C.1    Miller, J.A.2    Moran, J.R.3    Ward, M.D.4
  • 9
    • 0023475432 scopus 로고
    • Application of polymer-coated glassy carbon electrodes to the direct determination of trace metals in body fluids by anodic stripping voltammetry
    • B. Hoyer, and T.M. Florence Application of polymer-coated glassy carbon electrodes to the direct determination of trace metals in body fluids by anodic stripping voltammetry Anal. Chem. 59 1987 2839
    • (1987) Anal. Chem. , vol.59 , pp. 2839
    • Hoyer, B.1    Florence, T.M.2
  • 11
    • 0027476562 scopus 로고
    • Development of a piezoelectric immunosensor for the detection of human erythrocytes
    • B. Konig, and M. Gratzel Development of a piezoelectric immunosensor for the detection of human erythrocytes Anal. Chim. Acta 276 1993 329
    • (1993) Anal. Chim. Acta , vol.276 , pp. 329
    • Konig, B.1    Gratzel, M.2
  • 12
    • 0028372590 scopus 로고
    • A novel immunosensor for herpes viruses
    • B. Konig, and M. Gratzel A novel immunosensor for herpes viruses Anal. Chem. 66 1994 341
    • (1994) Anal. Chem. , vol.66 , pp. 341
    • Konig, B.1    Gratzel, M.2
  • 13
    • 0029082511 scopus 로고
    • New immunoassay techniques using Nafion-modified electrodes and cationic redox labels or enzyme labels
    • A. Le Gal La Salle, B. Limoges, S. Rapicault, C. Degrand, and P. Brossier New immunoassay techniques using Nafion-modified electrodes and cationic redox labels or enzyme labels Anal. Chim. Acta 311 1995 301
    • (1995) Anal. Chim. Acta , vol.311 , pp. 301
    • Le Gal1    La Salle, A.2    Limoges, B.3    Rapicault, S.4    Degrand, C.5    Brossier, P.6
  • 14
    • 0030945872 scopus 로고    scopus 로고
    • Reagentless amperometric biosensors highly sensitive to hydrogen peroxide, glucose and lactose based on N-methyl phenazine methosulfate incorporated in a Nafion film as an electron transfer mediator between horseradish peroxidase and an electrode
    • H. Liu, T. Yang, K. Sun, H. Li, and D. Qi Reagentless amperometric biosensors highly sensitive to hydrogen peroxide, glucose and lactose based on N-methyl phenazine methosulfate incorporated in a Nafion film as an electron transfer mediator between horseradish peroxidase and an electrode Anal. Chim. Acta 344 1997 187
    • (1997) Anal. Chim. Acta , vol.344 , pp. 187
    • Liu, H.1    Yang, T.2    Sun, K.3    Li, H.4    Qi, D.5
  • 17
    • 0023639408 scopus 로고
    • Piezoelectric crystal biosensor modified with protein a for determination of immunoglobulins
    • H. Muramatsu, J. Dicks, E. Tamia, and I. Karube Piezoelectric crystal biosensor modified with protein a for determination of immunoglobulins Anal. Chem. 59 1987 2760
    • (1987) Anal. Chem. , vol.59 , pp. 2760
    • Muramatsu, H.1    Dicks, J.2    Tamia, E.3    Karube, I.4
  • 18
    • 0030142226 scopus 로고    scopus 로고
    • A novel method of immobilizing antibodies on a quartz crystal microbalance using plasma-polymerized films for immunosensors
    • K. Nakanishi, H. Muguruma, and I. Karube A novel method of immobilizing antibodies on a quartz crystal microbalance using plasma-polymerized films for immunosensors Anal. Chem. 68 1996 1695
    • (1996) Anal. Chem. , vol.68 , pp. 1695
    • Nakanishi, K.1    Muguruma, H.2    Karube, I.3
  • 19
    • 0021016188 scopus 로고
    • Complement polymorphism, the major histocompatibility complex and associated diseases: A speculation
    • R.R. Porter Complement polymorphism, the major histocompatibility complex and associated diseases: a speculation Mol. Biol. Med. 1 1983 161
    • (1983) Mol. Biol. Med. , vol.1 , pp. 161
    • Porter, R.R.1
  • 20
    • 84951279351 scopus 로고
    • Use of a quartz vibrator for weighing thin layers on a microbalance
    • G. Sauerbrey Use of a quartz vibrator for weighing thin layers on a microbalance Z. Phys. 155 1959 206
    • (1959) Z. Phys. , vol.155 , pp. 206
    • Sauerbrey, G.1
  • 21
    • 0343010447 scopus 로고    scopus 로고
    • Construction and characterization of the direct piezoelectric immunosensor for atrazine operating in solution
    • C. Steegborn, and P. Skladal Construction and characterization of the direct piezoelectric immunosensor for atrazine operating in solution Biosens. Bioelectron. 12 1997 19
    • (1997) Biosens. Bioelectron. , vol.12 , pp. 19
    • Steegborn, C.1    Skladal, P.2
  • 22
    • 0027999228 scopus 로고
    • Determination of immunoglobulin M concentration by piezoelectric crystal immunobiosensor coated with protamine
    • C.R. Suri, M. Raje, and G.C. Mishra Determination of immunoglobulin M concentration by piezoelectric crystal immunobiosensor coated with protamine Biosens. Bioelectron. 9 1994 325
    • (1994) Biosens. Bioelectron. , vol.9 , pp. 325
    • Suri, C.R.1    Raje, M.2    Mishra, G.C.3
  • 23
    • 0346977001 scopus 로고
    • Integrated Press of Beijing Medical University and Peking Union Medical College, Beijing
    • Wang, S.J., 1992. Experimental Diagnostics, Integrated Press of Beijing Medical University and Peking Union Medical College, Beijing, p. 91.
    • (1992) Experimental Diagnostics , pp. 91
    • Wang, S.J.1
  • 24
    • 0034621335 scopus 로고    scopus 로고
    • A novel approach of antibody immobilization based on n-butyl amine plasma-polymerized films for immunosensors
    • Z.Y. Wu, Y.H. Yan, G.L. Shen, and R.Q. Yu A novel approach of antibody immobilization based on n-butyl amine plasma-polymerized films for immunosensors Anal. Chim. Acta 412 2000 29
    • (2000) Anal. Chim. Acta , vol.412 , pp. 29
    • Wu, Z.Y.1    Yan, Y.H.2    Shen, G.L.3    Yu, R.Q.4
  • 25
    • 0034614640 scopus 로고    scopus 로고
    • Mutational analysis of the primary substrate specificity pocket of complement factor B
    • Y.Y. Xu, A. Circolo, H. Jing, Y. Wang, S.V.L. Narayana, and J.E. Volanakis Mutational analysis of the primary substrate specificity pocket of complement factor B J. Biol. Chem. 275 2000 378
    • (2000) J. Biol. Chem. , vol.275 , pp. 378
    • Xu, Y.Y.1    Circolo, A.2    Jing, H.3    Wang, Y.4    Narayana, S.V.L.5    Volanakis, J.E.6
  • 26
    • 0001132263 scopus 로고
    • Adsorption, immobilization, and hybridization of DNA studied by the use of quartz crystal oscillators
    • S. Yamaguchi, T. Shimomura, T. Tatsuma, and N. Oyama Adsorption, immobilization, and hybridization of DNA studied by the use of quartz crystal oscillators Anal. Chem. 65 1993 1925
    • (1993) Anal. Chem. , vol.65 , pp. 1925
    • Yamaguchi, S.1    Shimomura, T.2    Tatsuma, T.3    Oyama, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.