메뉴 건너뛰기




Volumn 341, Issue 2, 2005, Pages 259-266

Salicylate poly(vinyl chloride) membrane electrode based on (2-[(E)-2-(4-nitrophenyl) hydrazono]-1-phenyl-2-(2-quinolyl)-1-ethanone) Cu(II)

Author keywords

Ion selective electrode; Ionophore; Salicylate selective electrode

Indexed keywords

CHLORINE COMPOUNDS; ION SELECTIVE ELECTRODES; IONOPHORES; POLYVINYL CHLORIDES;

EID: 19444373143     PISSN: 00032697     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ab.2005.03.040     Document Type: Article
Times cited : (15)

References (41)
  • 1
    • 37049069896 scopus 로고
    • Historical perspective: History of early commercialization of ion-selective electrodes
    • M.S. Frant Historical perspective: history of early commercialization of ion-selective electrodes Analyst 119 1994 2293
    • (1994) Analyst , vol.119 , pp. 2293
    • Frant, M.S.1
  • 2
    • 0032099044 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes: II. Ionophores for potentiometric and optical sensors
    • P. Bühlmann, E. Pretsch, and E. Bakker Carrier-based ion-selective electrodes and bulk optodes: II. Ionophores for potentiometric and optical sensors Chem. Rev. 98 1998 1593 1687
    • (1998) Chem. Rev. , vol.98 , pp. 1593-1687
    • Bühlmann, P.1    Pretsch, E.2    Bakker, E.3
  • 3
    • 4544366331 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes: I. General characteristics
    • E. Bakker, P. Bühlmann, and E. Pretsch Carrier-based ion-selective electrodes and bulk optodes: I. General characteristics Chem. Rev. 97 1997 3083 3132
    • (1997) Chem. Rev. , vol.97 , pp. 3083-3132
    • Bakker, E.1    Bühlmann, P.2    Pretsch, E.3
  • 4
    • 0030020160 scopus 로고    scopus 로고
    • Solid-contact ion-selective electrode with stable internal electrode
    • M. Vamvakaki, and N.A. Chaniotakis Solid-contact ion-selective electrode with stable internal electrode Anal. Chim. Acta 320 1996 53 61
    • (1996) Anal. Chim. Acta , vol.320 , pp. 53-61
    • Vamvakaki, M.1    Chaniotakis, N.A.2
  • 5
    • 0030595803 scopus 로고    scopus 로고
    • Optical films for protamine detection with lipophilic dichlorofluorescein derivatives
    • E. Wang, G. Wang, L. Ma, C.M. Stivanello, S. Lam, and H. Patel Optical films for protamine detection with lipophilic dichlorofluorescein derivatives Anal. Chim. Acta 334 1996 139 147
    • (1996) Anal. Chim. Acta , vol.334 , pp. 139-147
    • Wang, E.1    Wang, G.2    Ma, L.3    Stivanello, C.M.4    Lam, S.5    Patel, H.6
  • 6
    • 0024997239 scopus 로고
    • New in vitro analytical approaches for clinical chemistry measurements in critical care
    • M.E. Meyerhoff New in vitro analytical approaches for clinical chemistry measurements in critical care Clin. Chem. 36 1990 1567 1572
    • (1990) Clin. Chem. , vol.36 , pp. 1567-1572
    • Meyerhoff, M.E.1
  • 8
    • 0025079993 scopus 로고
    • Polymeric membrane anion-selective electrodes based on diquaternary ammonium salts
    • V.J. Wotring, D.M. Johnson, and L.G. Bachas Polymeric membrane anion-selective electrodes based on diquaternary ammonium salts Anal. Chem. 62 1990 1506 1510
    • (1990) Anal. Chem. , vol.62 , pp. 1506-1510
    • Wotring, V.J.1    Johnson, D.M.2    Bachas, L.G.3
  • 9
    • 0001752478 scopus 로고
    • Nitrite selective electrode developed by electrochemically mediated imprinting/doping of polypyrrole
    • R.S. Hutchins, and L.G. Bachas Nitrite selective electrode developed by electrochemically mediated imprinting/doping of polypyrrole Anal. Chem. 67 1995 1654 1660
    • (1995) Anal. Chem. , vol.67 , pp. 1654-1660
    • Hutchins, R.S.1    Bachas, L.G.2
  • 10
    • 0035216786 scopus 로고    scopus 로고
    • A nitrate-selective electrode based on Tris(2,2′, 2″-salicylideneimino) triethylamine
    • N. Aslan (Yilmaz), A. Kenar, O. Atakol, and E. Kilic A nitrate-selective electrode based on Tris(2,2′, 2″-salicylideneimino) triethylamine Anal. Sci. 17 2001 1269 1272
    • (2001) Anal. Sci. , vol.17 , pp. 1269-1272
    • Aslan, N.1    Kenar, A.2    Atakol, O.3    Kilic, E.4
  • 11
    • 0242286115 scopus 로고    scopus 로고
    • Selective thiocyanate poly(vinyl chloride) membrane based on a 1,8-dibenzyl-1,3,6,8,10,13-hexaazacyclotetradecane-Ni(II) perchlorate
    • M. Mazloum, A.A. Ensafi, M. Salavati, and S. Mirhoseini Selective thiocyanate poly(vinyl chloride) membrane based on a 1,8-dibenzyl-1,3,6,8,10,13- hexaazacyclotetradecane-Ni(II) perchlorate Anal. Chim. Acta 462 2002 25 30
    • (2002) Anal. Chim. Acta , vol.462 , pp. 25-30
    • Mazloum, M.1    Ensafi, A.A.2    Salavati, M.3    Mirhoseini, S.4
  • 12
    • 0030359876 scopus 로고    scopus 로고
    • Ion-selective electrode for salicylate assay in blood serum
    • T. Katsu, and Y. Mori Ion-selective electrode for salicylate assay in blood serum Talanta 43 1996 755 759
    • (1996) Talanta , vol.43 , pp. 755-759
    • Katsu, T.1    Mori, Y.2
  • 13
    • 0024298603 scopus 로고
    • Aspirin for the primary prevention of myocardial infarction
    • A. Relman Aspirin for the primary prevention of myocardial infarction N. Engl. J. Med. 318 1988 245 246
    • (1988) N. Engl. J. Med. , vol.318 , pp. 245-246
    • Relman, A.1
  • 14
    • 33947315674 scopus 로고
    • Anion responsive electrodes based on ion association extraction systems
    • C.J. Coetzee, and H. Freiser Anion responsive electrodes based on ion association extraction systems Anal. Chem. 40 1968 2071
    • (1968) Anal. Chem. , vol.40 , pp. 2071
    • Coetzee, C.J.1    Freiser, H.2
  • 15
    • 0000102457 scopus 로고
    • Liquid-liquid membrane electrode based on ion association extraction systems
    • C.J. Coetzee, and H. Freiser Liquid-liquid membrane electrode based on ion association extraction systems Anal. Chem. 41 1969 1128
    • (1969) Anal. Chem. , vol.41 , pp. 1128
    • Coetzee, C.J.1    Freiser, H.2
  • 17
    • 24544456601 scopus 로고
    • Construction and analytical applications of an improved liquid-membrane electrode for salicylate
    • A. Mitsuna-Papazoglou, E.P. Diamandis, and T.P. Hadjiioannou Construction and analytical applications of an improved liquid-membrane electrode for salicylate Anal. Chim. Acta 159 1984 393
    • (1984) Anal. Chim. Acta , vol.159 , pp. 393
    • Mitsuna-Papazoglou, A.1    Diamandis, E.P.2    Hadjiioannou, T.P.3
  • 18
    • 0024515446 scopus 로고
    • Salicylate-selective membrane electrode based on Tin(IV) tetraphenylporphyrin
    • N.A. Chaniotakis, S.B. Park, and M.E. Meyerhoff Salicylate-selective membrane electrode based on Tin(IV) tetraphenylporphyrin Anal. Chem. 61 1989 566 570
    • (1989) Anal. Chem. , vol.61 , pp. 566-570
    • Chaniotakis, N.A.1    Park, S.B.2    Meyerhoff, M.E.3
  • 19
    • 0000020499 scopus 로고
    • Anion-selective membrane electrodes based on metalloporphyrins: The influence of lipophilic anionic and cationic sites on potentiometric selectivity
    • E. Bakker, E. Maliowska, K.D. Schiller, and M.E. Meyerhoff Anion-selective membrane electrodes based on metalloporphyrins: the influence of lipophilic anionic and cationic sites on potentiometric selectivity Talanta 41 1994 881 890
    • (1994) Talanta , vol.41 , pp. 881-890
    • Bakker, E.1    Maliowska, E.2    Schiller, K.D.3    Meyerhoff, M.E.4
  • 20
    • 0000180624 scopus 로고
    • Salicylate-selective electrode based on lipophilic Tin(IV) phthalocyanine
    • J.J. Li, X.J. Pang, D. Gao, and R.Q. Yu Salicylate-selective electrode based on lipophilic Tin(IV) phthalocyanine Talanta 42 1995 1775 1781
    • (1995) Talanta , vol.42 , pp. 1775-1781
    • Li, J.J.1    Pang, X.J.2    Gao, D.3    Yu, R.Q.4
  • 21
    • 0005730072 scopus 로고
    • Ion-selective electrodes based on siderophores: Salicylate response of a ferrimycobactin membrane
    • D. Midgley Ion-selective electrodes based on siderophores: salicylate response of a ferrimycobactin membrane Anal. Chim. Acta 182 1986 91
    • (1986) Anal. Chim. Acta , vol.182 , pp. 91
    • Midgley, D.1
  • 22
    • 0028942958 scopus 로고
    • Anion selective polymeric membrane electrodes based on metallocenes
    • H. Hisamoto, D. Siswanta, H. Nishihara, and K. Suzuki Anion selective polymeric membrane electrodes based on metallocenes Anal. Chim. Acta 304 1995 171 176
    • (1995) Anal. Chim. Acta , vol.304 , pp. 171-176
    • Hisamoto, H.1    Siswanta, D.2    Nishihara, H.3    Suzuki, K.4
  • 23
    • 0034161659 scopus 로고    scopus 로고
    • Salicylate-selective electrode based on Al(III) and An(IV) salophens
    • S. Shahrokhian, M.K. Amini, R. Kia, and S. Tangestaninejad Salicylate-selective electrode based on Al(III) and An(IV) salophens Anal. Chem. 72 2000 956 962
    • (2000) Anal. Chem. , vol.72 , pp. 956-962
    • Shahrokhian, S.1    Amini, M.K.2    Kia, R.3    Tangestaninejad, S.4
  • 24
    • 0024106504 scopus 로고
    • Copper(II)-selective electrode using thorium disulfide neutral carrier
    • S. Kamata, A. Bhal, Y. Fakunaga, and A. Marata Copper(II)-selective electrode using thorium disulfide neutral carrier Anal. Chem. 60 1988 2464
    • (1988) Anal. Chem. , vol.60 , pp. 2464
    • Kamata, S.1    Bhal, A.2    Fakunaga, Y.3    Marata, A.4
  • 26
    • 84953464479 scopus 로고
    • Reduction of anion interference in neutral carrier liquid membrane electrodes responsive to cations
    • W.E. Morf, G. Khar, and W. Simon Reduction of anion interference in neutral carrier liquid membrane electrodes responsive to cations Anal. Lett. 7 1974 9
    • (1974) Anal. Lett. , vol.7 , pp. 9
    • Morf, W.E.1    Khar, G.2    Simon, W.3
  • 27
    • 0032701533 scopus 로고    scopus 로고
    • Thiocyanate-selective electrodes based on nickel and iron phthalocyanines
    • M.K. Amini, S. Shahrokhian, and S. Tangestaninejad Thiocyanate-selective electrodes based on nickel and iron phthalocyanines Anal. Chim. Acta 402 1999 137 143
    • (1999) Anal. Chim. Acta , vol.402 , pp. 137-143
    • Amini, M.K.1    Shahrokhian, S.2    Tangestaninejad, S.3
  • 28
    • 0027318944 scopus 로고
    • Trioctyltin chloride as carrier for a chloride-selective electrode in flow-injection potentiometry
    • P.C. Hauser Trioctyltin chloride as carrier for a chloride-selective electrode in flow-injection potentiometry Anal. Chim. Acta 278 1993 227
    • (1993) Anal. Chim. Acta , vol.278 , pp. 227
    • Hauser, P.C.1
  • 29
    • 0000224837 scopus 로고
    • Incorporation of dodecylbenzene sulfonic acid in a poly(vinyl) chloride matrix chloride ion-selective membrane based on tertiary ammonium
    • S. Nomura Incorporation of dodecylbenzene sulfonic acid in a poly(vinyl) chloride matrix chloride ion-selective membrane based on tertiary ammonium Analyst 120 1995 503
    • (1995) Analyst , vol.120 , pp. 503
    • Nomura, S.1
  • 30
    • 0033168726 scopus 로고    scopus 로고
    • PVC-based Mn(II) porphyrin membrane coated graphite electrode for determination of histidine
    • M.K. Amini, and S. Shahrokhian PVC-based Mn(II) porphyrin membrane coated graphite electrode for determination of histidine Anal. Chem. 71 1999 2502 2505
    • (1999) Anal. Chem. , vol.71 , pp. 2502-2505
    • Amini, M.K.1    Shahrokhian, S.2
  • 32
    • 0019008094 scopus 로고
    • Lifetime of neutral carrier based ion-selective liquid membrane electrodes
    • U. Oesch, and W. Simon Lifetime of neutral carrier based ion-selective liquid membrane electrodes Anal. Chem. 52 1980 692 700
    • (1980) Anal. Chem. , vol.52 , pp. 692-700
    • Oesch, U.1    Simon, W.2
  • 33
    • 0002441594 scopus 로고
    • Properties of PVC based membranes used in ion-selective electrodes
    • R.D. Armstrong, and G. Horvai Properties of PVC based membranes used in ion-selective electrodes Electrochim. Acta 35 1990 1 7
    • (1990) Electrochim. Acta , vol.35 , pp. 1-7
    • Armstrong, R.D.1    Horvai, G.2
  • 35
    • 0000782193 scopus 로고
    • Ion selective electrodes, potentiometry, and potentiometric titrations
    • R.P. Buck Ion selective electrodes, potentiometry, and potentiometric titrations Anal. Chem. 44 1972 270R 295R
    • (1972) Anal. Chem. , vol.44
    • Buck, R.P.1
  • 37
    • 84930167786 scopus 로고
    • IUPAC recommendations for nomenclature of ion-selective electrodes
    • R.P. Buck, and E. Lindner IUPAC recommendations for nomenclature of ion-selective electrodes Pure Appl. Chem. 66 1994 2527 2536
    • (1994) Pure Appl. Chem. , vol.66 , pp. 2527-2536
    • Buck, R.P.1    Lindner, E.2
  • 38
    • 0000530842 scopus 로고
    • Anion selective electrodes based on electropolymerized porphyrin films
    • S. Daunert, S. Wallace, A. Florido, and L.G. Bachas Anion selective electrodes based on electropolymerized porphyrin films Anal. Chem. 63 1991 1676 1679
    • (1991) Anal. Chem. , vol.63 , pp. 1676-1679
    • Daunert, S.1    Wallace, S.2    Florido, A.3    Bachas, L.G.4
  • 40
    • 0035082379 scopus 로고    scopus 로고
    • Comparative study of the metal phthalocyanates as active components in salicylate-selective electrodes
    • N.N. Leyzerovich, N.V. Shvedene, Y.N. Bilkova, L.G. Tomilova, and I.V. Pletnev Comparative study of the metal phthalocyanates as active components in salicylate-selective electrodes Electroanalysis 3 2001 246 256
    • (2001) Electroanalysis , vol.3 , pp. 246-256
    • Leyzerovich, N.N.1    Shvedene, N.V.2    Bilkova, Y.N.3    Tomilova, L.G.4    Pletnev, I.V.5
  • 41
    • 0004206781 scopus 로고
    • Cambridge University Press, Cambridge, UK
    • British Pharmacopoeia, vol. 2, Cambridge University Press, Cambridge, UK, 1993
    • (1993) British Pharmacopoeia , vol.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.