메뉴 건너뛰기




Volumn 28, Issue 15, 2004, Pages

On-line insulator contamination monitoring system for transmission lines based on telemetry

Author keywords

Insulator contamination; Leakage current; On line monitoring system; Transmission line

Indexed keywords

ATMOSPHERIC HUMIDITY; CONDITION MONITORING; CONTAMINATION; DATA ACQUISITION; ELECTRIC INSULATION; ELECTRIC LINES; EXPERT SYSTEMS; LEAKAGE CURRENTS; ONLINE SYSTEMS; TRANSMISSION LINE THEORY; WIRELESS TELECOMMUNICATION SYSTEMS;

EID: 19444364908     PISSN: 10001026     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (15)

References (8)
  • 4
    • 4344688489 scopus 로고    scopus 로고
    • Design of insulator contamination online detecting technique for substation
    • Ren Haipeng, Liu Ding, Li Qi, et al. Design of Insulator Contamination Online Detecting Technique for Substation. Transactions of China Electrotechnical Society, 2002, 17(73): 77-80
    • (2002) Transactions of China Electrotechnical Society , vol.17 , Issue.73 , pp. 77-80
    • Ren, H.1    Liu, D.2    Li, Q.3
  • 5
    • 0035429515 scopus 로고    scopus 로고
    • Study of adaptive noise cancellation used in measuring HV insulator's leakage current
    • Liu Dichen, Xia Limin, Shang Zhihui, et al. Study of Adaptive Noise Cancellation Used in Measuring H V Insulator's Leakage Current. Engineering Journal of Wuhan University, 2001, 34(4): 96-99
    • (2001) Engineering Journal of Wuhan University , vol.34 , Issue.4 , pp. 96-99
    • Liu, D.1    Xia, L.2    Shang, Z.3
  • 6
    • 4644272757 scopus 로고    scopus 로고
    • An online monitoring and measurement system of insulators leaky current
    • Liu Jinhua, Zhou Yongqiang, Xu Lvfei, et al. An Online Monitoring and Measurement System of Insulators Leaky Current. Central China Electric Power, 2000, 13(2): 8-10
    • (2000) Central China Electric Power , vol.13 , Issue.2 , pp. 8-10
    • Liu, J.1    Zhou, Y.2    Xu, L.3
  • 7
    • 4344615168 scopus 로고    scopus 로고
    • A new method of online measuring the degree of pollution insulators of power lines
    • Zhou Wenjun, Li Jun, Yin Zhide, et al. A New Method of Online Measuring the Degree of Pollution Insulators of Power Lines. Electric Power, 1998, 31(6): 15-17
    • (1998) Electric Power , vol.31 , Issue.6 , pp. 15-17
    • Zhou, W.1    Li, J.2    Yin, Z.3
  • 8
    • 0037057048 scopus 로고    scopus 로고
    • Online monitoring system for polluted insulator based on telemetry
    • Cai Wei, Li Min, Yang Yanhong, et al. Online Monitoring System for Polluted Insulator Based on Telemetry. Automation of Electric Power Systems, 2002, 26(17): 45-48
    • (2002) Automation of Electric Power Systems , vol.26 , Issue.17 , pp. 45-48
    • Cai, W.1    Li, M.2    Yang, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.