메뉴 건너뛰기




Volumn 23, Issue 4, 2004, Pages 323-326

Quantification of power Doppler and the index 'fractional moving blood volume' (FMBV)

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; BLOOD FLOW; BLOOD SAMPLING; BLOOD VOLUME; CORRELATION ANALYSIS; DOPPLER FLOWMETRY; FLOW RATE; FRACTIONATION; FUTUROLOGY; HUMAN; IMAGING SYSTEM; MATHEMATICAL COMPUTING; NONHUMAN; NOTE; PERFUSION; PRIORITY JOURNAL; STANDARDIZATION; STATISTICAL SIGNIFICANCE; TECHNIQUE; VASCULAR ACCESS; VASCULARIZATION;

EID: 1942500251     PISSN: 09607692     EISSN: None     Source Type: Journal    
DOI: 10.1002/uog.1037     Document Type: Note
Times cited : (37)

References (36)
  • 2
    • 0025808995 scopus 로고
    • Doppler investigation of the fetal circulation
    • Campbell S, Vyas S, Nicolaides KH. Doppler investigation of the fetal circulation. J Perinat Med 1991; 19: 21-26.
    • (1991) J Perinat Med , vol.19 , pp. 21-26
    • Campbell, S.1    Vyas, S.2    Nicolaides, K.H.3
  • 6
    • 1242269817 scopus 로고    scopus 로고
    • Doppler application in the delivery timing of the preterm growth-restricted fetus: Another step in the right direction
    • Baschat AA. Doppler application in the delivery timing of the preterm growth-restricted fetus: another step in the right direction. Ultrasound Obstet Gynecol 2004; 23: 111-118.
    • (2004) Ultrasound Obstet Gynecol , vol.23 , pp. 111-118
    • Baschat, A.A.1
  • 9
    • 0028805996 scopus 로고
    • Technical note: Comparison of colour Doppler energy sonography with conventional colour Doppler sonography in detection of flow signal in peripheral renal transplant vessels
    • Preidler KW, Szolar DM, Uggowitzer M, Stiskal M, Horina J. Technical note: comparison of colour Doppler energy sonography with conventional colour Doppler sonography in detection of flow signal in peripheral renal transplant vessels. Br J Radiol 1995; 68: 1103-1105.
    • (1995) Br J Radiol , vol.68 , pp. 1103-1105
    • Preidler, K.W.1    Szolar, D.M.2    Uggowitzer, M.3    Stiskal, M.4    Horina, J.5
  • 10
    • 0028136387 scopus 로고
    • Power versus conventional color Doppler sonography: Comparison in the depiction of normal intrarenal vasculature
    • Bude RO, Rubin JM, Adler RS. Power versus conventional color Doppler sonography: comparison in the depiction of normal intrarenal vasculature. Radiology 1994; 192: 777-780.
    • (1994) Radiology , vol.192 , pp. 777-780
    • Bude, R.O.1    Rubin, J.M.2    Adler, R.S.3
  • 11
    • 0031260568 scopus 로고    scopus 로고
    • Color Doppler energy: Computer analysis for detection of volume flow variations
    • Nilsson A, Olofsson PA, Loren I, Carlstedt L, Nilsson P. Color Doppler energy: computer analysis for detection of volume flow variations. J Ultrasound Med 1997; 16: 679-684.
    • (1997) J Ultrasound Med , vol.16 , pp. 679-684
    • Nilsson, A.1    Olofsson, P.A.2    Loren, I.3    Carlstedt, L.4    Nilsson, P.5
  • 12
    • 0029047680 scopus 로고
    • Segmentation and analysis of colour Doppler images of tumour vasculature
    • Bell DS, Bamber JC, Eckersley RJ. Segmentation and analysis of colour Doppler images of tumour vasculature. Ultrasound Med Biol 1995; 21: 635-647.
    • (1995) Ultrasound Med Biol , vol.21 , pp. 635-647
    • Bell, D.S.1    Bamber, J.C.2    Eckersley, R.J.3
  • 16
    • 0028784524 scopus 로고
    • Colour Doppler image analysis for tissue vascularity and perfusion: A preliminary clinical evaluation
    • Hirsch W, Bell DS, Crawford DC, Kale SG, McCready VR, Bamber JC. Colour Doppler image analysis for tissue vascularity and perfusion: a preliminary clinical evaluation. Ultrasound Med Biol 1995; 21: 1107-1117.
    • (1995) Ultrasound Med Biol , vol.21 , pp. 1107-1117
    • Hirsch, W.1    Bell, D.S.2    Crawford, D.C.3    Kale, S.G.4    McCready, V.R.5    Bamber, J.C.6
  • 17
    • 0029086299 scopus 로고
    • Automated quantification of color Doppler signals: A preliminary study in breast tumors
    • Kedar RP, Cosgrove DO, Bamber JC, Bell DS. Automated quantification of color Doppler signals: a preliminary study in breast tumors. Radiology 1995; 197: 39-43.
    • (1995) Radiology , vol.197 , pp. 39-43
    • Kedar, R.P.1    Cosgrove, D.O.2    Bamber, J.C.3    Bell, D.S.4
  • 20
    • 0026058754 scopus 로고
    • Measurement of blood perfusion in tissue using Doppler ultrasound
    • Dymling SO, Persson HW, Hertz CH. Measurement of blood perfusion in tissue using Doppler ultrasound. Ultrasound Med Biol 1991; 17: 433-444.
    • (1991) Ultrasound Med Biol , vol.17 , pp. 433-444
    • Dymling, S.O.1    Persson, H.W.2    Hertz, C.H.3
  • 22
    • 0031178915 scopus 로고    scopus 로고
    • Can relative contrast agent concentration be measured in vivo with color Doppler US?
    • Blomley MJ, Albrecht T, Cosgrove DO, Bamber JC. Can relative contrast agent concentration be measured in vivo with color Doppler US? Radiology 1997; 204: 279-281.
    • (1997) Radiology , vol.204 , pp. 279-281
    • Blomley, M.J.1    Albrecht, T.2    Cosgrove, D.O.3    Bamber, J.C.4
  • 23
    • 1242296263 scopus 로고    scopus 로고
    • Quantifying the changes in endometrial vascularity throughout the normal menstrual cycle with three-dimensional power Doppler angiography
    • Raine-Fenning NJ, Campbell BK, Kendall NR, Clewes JS, Johnson IR. Quantifying the changes in endometrial vascularity throughout the normal menstrual cycle with three-dimensional power Doppler angiography. Hum Reprod 2004; 19: 330-338.
    • (2004) Hum Reprod , vol.19 , pp. 330-338
    • Raine-Fenning, N.J.1    Campbell, B.K.2    Kendall, N.R.3    Clewes, J.S.4    Johnson, I.R.5
  • 24
    • 0346333055 scopus 로고    scopus 로고
    • The reliability of virtual organ computer-aided analysis (VOCAL) for the semiquantification of ovarian, endometrial and subendometrial perfusion
    • Raine-Fenning NJ, Campbell BK, Clewes JS, Kendall NR, Johnson IR. The reliability of virtual organ computer-aided analysis (VOCAL) for the semiquantification of ovarian, endometrial and subendometrial perfusion. Ultrasound Obstet Gynecol 2003; 22: 633-639.
    • (2003) Ultrasound Obstet Gynecol , vol.22 , pp. 633-639
    • Raine-Fenning, N.J.1    Campbell, B.K.2    Clewes, J.S.3    Kendall, N.R.4    Johnson, I.R.5
  • 25
    • 0037707377 scopus 로고    scopus 로고
    • Quantitative three-dimensional power Doppler sonography for assessment of the fetal renal blood flow in normal gestation
    • Chang C, Yu C, Ko H, Chien W, Chang F. Quantitative three-dimensional power Doppler sonography for assessment of the fetal renal blood flow in normal gestation. Ultrasound Med Biol 2003; 29: 929-933.
    • (2003) Ultrasound Med Biol , vol.29 , pp. 929-933
    • Chang, C.1    Yu, C.2    Ko, H.3    Chien, W.4    Chang, F.5
  • 28
    • 0023769665 scopus 로고
    • Umbilical and uteroplacental blood flow velocity waveform in normal pregnancy - A cross-sectional study
    • Gudmundsson S, Marsal K. Umbilical and uteroplacental blood flow velocity waveform in normal pregnancy - a cross-sectional study. Acta Obstet Gynecol Scand 1988; 67: 347-354.
    • (1988) Acta Obstet Gynecol Scand , vol.67 , pp. 347-354
    • Gudmundsson, S.1    Marsal, K.2
  • 31
    • 0034980047 scopus 로고    scopus 로고
    • Comparison of power Doppler and velocimetry in predicting outcome of high-risk pregnancy
    • Dubiel M, Dobek A, Breborowicz G, Marsal K, Gudmundsson S. Comparison of power Doppler and velocimetry in predicting outcome of high-risk pregnancy. Eur J Ultrasound 2001; 12: 197-202.
    • (2001) Eur J Ultrasound , vol.12 , pp. 197-202
    • Dubiel, M.1    Dobek, A.2    Breborowicz, G.3    Marsal, K.4    Gudmundsson, S.5
  • 32
    • 0030657637 scopus 로고    scopus 로고
    • Normalizing fractional moving blood volume estimates with power Doppler US: Defining a stable intravascular point with the cumulative power distribution function
    • Rubin JM, Bude RO, Fowlkes JB, Spratt RS, Carson PL, Adler RS. Normalizing fractional moving blood volume estimates with power Doppler US: defining a stable intravascular point with the cumulative power distribution function. Radiology 1997; 205: 757-765.
    • (1997) Radiology , vol.205 , pp. 757-765
    • Rubin, J.M.1    Bude, R.O.2    Fowlkes, J.B.3    Spratt, R.S.4    Carson, P.L.5    Adler, R.S.6
  • 33
    • 0345707661 scopus 로고    scopus 로고
    • Estimation of fractional moving blood volume in fetal lung using power Doppler ultrasound; methodological aspects
    • Jansson T, Hernandez-Andrade E, Lingman G, Marsal K. Estimation of fractional moving blood volume in fetal lung using power Doppler ultrasound; methodological aspects. Ultrasound Med Biol 2003; 29: 1551-1559.
    • (2003) Ultrasound Med Biol , vol.29 , pp. 1551-1559
    • Jansson, T.1    Hernandez-Andrade, E.2    Lingman, G.3    Marsal, K.4
  • 35


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.