메뉴 건너뛰기




Volumn 5165, Issue , 2004, Pages 482-496

Chandra X-ray Observatory Mirror Effective Area

Author keywords

Calibration; Chandra X ray Observatory; Effective area; HRMA; X ray mirrors; X ray telescopes

Indexed keywords

CALIBRATION; IMAGING TECHNIQUES; MIRRORS; OBSERVATORIES; SPECTROSCOPY; TELESCOPES; X RAY OPTICS;

EID: 1942487230     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.509379     Document Type: Conference Paper
Times cited : (20)

References (8)
  • 1
    • 0032298495 scopus 로고    scopus 로고
    • AXAF mirror effective area calibration using the C-continuum source and solid state detectors
    • X-Ray Optics, Instruments, and Missions, Hoover and Walker, eds.
    • P. Zhao et al., "AXAF mirror effective area calibration using the C-continuum source and solid state detectors," in X-Ray Optics, Instruments, and Missions, Hoover and Walker, eds., Proc. SPIE 3444, p. 234, 1998.
    • (1998) Proc. SPIE , vol.3444 , pp. 234
    • Zhao, P.1
  • 2
    • 0010151592 scopus 로고    scopus 로고
    • Uses of continuum radiation on the axaf calibration
    • Grazing Incidence and Multilayer X-Ray Optical Systems, Hoover and Walker, eds.
    • J. Kolodziejczak et al., "Uses of continuum radiation on the axaf calibration," in Grazing Incidence and Multilayer X-Ray Optical Systems, Hoover and Walker, eds., Proc. SPIE 3113, p. 65, 1997.
    • (1997) Proc. SPIE , vol.3113 , pp. 65
    • Kolodziejczak, J.1
  • 3
    • 0033682394 scopus 로고    scopus 로고
    • Absolute effective area of the chandra High-Resolution Mirror Assembly (HRMA)
    • X-Ray Optics, Instruments, and Missions III, Truemper and Aschenbach, eds.
    • D. schwartz et al., "Absolute effective area of the chandra High-Resolution Mirror Assembly (HRMA)," in X-Ray Optics, Instruments, and Missions III, Truemper and Aschenbach, eds., Proc. SPIE 4012, p. 28, 2000.
    • (2000) Proc. SPIE , vol.4012 , pp. 28
    • Schwartz, D.1
  • 4
    • 0031305902 scopus 로고    scopus 로고
    • Spectral fitting in axaf calibration detectors
    • Grazing Incidence and Multilayer X-Ray Optical Systems, Hoover and Walker, eds.
    • R. Edgar et al., "Spectral fitting in axaf calibration detectors," in Grazing Incidence and Multilayer X-Ray Optical Systems, Hoover and Walker, eds., Proc. SPIE 3113, p. 124, 1997.
    • (1997) Proc. SPIE , vol.3113 , pp. 124
    • Edgar, R.1
  • 5
    • 11144357721 scopus 로고    scopus 로고
    • The role of modeling in the calibration of chandra's optics
    • X-ray and Gamma-ray instrumentation for astronomu XIII, Flanagan and Siegmund, eds.
    • D. Jerius et al., "The role of modeling in the calibration of chandra's optics," in X-ray and Gamma-ray instrumentation for astronomu XIII, Flanagan and Siegmund, eds., Proc. SPIE 5165-40, 2003.
    • (2003) Proc. SPIE , vol.5165 , Issue.40
    • Jerius, D.1
  • 6
    • 0004932883 scopus 로고
    • X-ray interactions: Photoabsorpion, scattering, transmission, and reflection at E=50-30,000 eV, Z=l-92
    • L. Henke et al., "X-ray interactions: photoabsorpion, scattering, transmission, and reflection at E=50-30,000 eV, Z=l-92, http://www-cxro.lbl.gov/ optical_constants/," in Atomic Data and Nuclear Data Tables, 54, p. 181, 1993.
    • (1993) Atomic Data and Nuclear Data Tables , vol.54 , pp. 181
    • Henke, L.1
  • 7
    • 1942471373 scopus 로고    scopus 로고
    • Iridium optical constant for the chandra x-ray observatory from reflectance meansurement of 0.05-12 kev
    • X-ray and Gamma-ray instrumentation for astronomu XIII, Flanagan and Siegmund, eds.
    • D. Graessle et al., "Iridium optical constant for the chandra x-ray observatory from reflectance meansurement of 0.05-12 kev," in X-ray and Gamma-ray instrumentation for astronomu XIII, Flanagan and Siegmund, eds., Proc. SPIE 5165-46, 2003.
    • (2003) Proc. SPIE , vol.5165 , Issue.46
    • Graessle, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.