메뉴 건너뛰기




Volumn 98, Issue 5, 2004, Pages 1232-1238

Automated Cardiac Output Measurement by Transesophageal Color Doppler Echocardiography

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; AUTOMATION; CLINICAL ARTICLE; COLOR ULTRASOUND FLOWMETRY; CONTROLLED STUDY; CORRELATION ANALYSIS; DOPPLER ECHOCARDIOGRAPHY; FEMALE; FLOW MEASUREMENT; HEART LEFT VENTRICLE EJECTION FRACTION; HEART OUTPUT; HEART SURGERY; HUMAN; LUNG ARTERY; MALE; MITRAL VALVE; PRIORITY JOURNAL; THERMODILUTION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 1942467944     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/01.ANE.0000112314.94283.24     Document Type: Article
Times cited : (16)

References (24)
  • 1
    • 0021348906 scopus 로고
    • Determination of cardiac output by transcutaneous continuous-wave ultrasonic Doppler computer
    • Chandraratna PA, Nanna M, McKay C, et al. Determination of cardiac output by transcutaneous continuous-wave ultrasonic Doppler computer. Am J Cardiol 1984;53:234-7.
    • (1984) Am J Cardiol , vol.53 , pp. 234-237
    • Chandraratna, P.A.1    Nanna, M.2    McKay, C.3
  • 2
    • 0021173362 scopus 로고
    • Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: Clinical validation of two new methods using the apical window
    • Lewis JF, Kuo LC, Nelson JG, et al. Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. Circulation 1984;70:425-31.
    • (1984) Circulation , vol.70 , pp. 425-431
    • Lewis, J.F.1    Kuo, L.C.2    Nelson, J.G.3
  • 3
    • 0022202962 scopus 로고
    • The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output
    • Labovitz AJ, Buckingham TA, Habermehl K, et al. The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output. Am Heart J 1985;109:327-32.
    • (1985) Am Heart J , vol.109 , pp. 327-332
    • Labovitz, A.J.1    Buckingham, T.A.2    Habermehl, K.3
  • 4
    • 0023200163 scopus 로고
    • Influence of sampling site and flow area on cardiac output measurements by Doppler echocardiography
    • Dittmann H, Voelker W, Karsch KR, Seipel L. Influence of sampling site and flow area on cardiac output measurements by Doppler echocardiography. J Am Coll Cardiol 1987;10:818-23.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 818-823
    • Dittmann, H.1    Voelker, W.2    Karsch, K.R.3    Seipel, L.4
  • 5
    • 0022411631 scopus 로고
    • Intraoperative detection of myocardial ischemia in high-risk patients: Electrocardiography versus two-dimensional transesophageal echocardiography
    • Smith JS, Cahalan MK, Benefiel DJ, et al. Intraoperative detection of myocardial ischemia in high-risk patients: electrocardiography versus two-dimensional transesophageal echocardiography. Circulation 1985;72:1015-21.
    • (1985) Circulation , vol.72 , pp. 1015-1021
    • Smith, J.S.1    Cahalan, M.K.2    Benefiel, D.J.3
  • 6
    • 0025086716 scopus 로고
    • Relationship of regional wall motion abnormalities to hemodynamic indices of myocardial oxygen supply and demand in patients undergoing CABG surgery
    • Leung JM, O'Kelly BF, Mangano DT. Relationship of regional wall motion abnormalities to hemodynamic indices of myocardial oxygen supply and demand in patients undergoing CABG surgery. Anesthesiology 1990;73:802-14.
    • (1990) Anesthesiology , vol.73 , pp. 802-814
    • Leung, J.M.1    O'Kelly, B.F.2    Mangano, D.T.3
  • 7
    • 0025117996 scopus 로고
    • The "natural history" of segmental wall motion abnormalities in patients undergoing noncardiac surgery: S. P. I. Research Group
    • London MJ, Tubau JF, Wong MG, et al. The "natural history" of segmental wall motion abnormalities in patients undergoing noncardiac surgery: S. P. I. Research Group. Anesthesiology 1990;73:644-55.
    • (1990) Anesthesiology , vol.73 , pp. 644-655
    • London, M.J.1    Tubau, J.F.2    Wong, M.G.3
  • 8
    • 0025239151 scopus 로고
    • Relation of pulmonary vein to mitral flow velocities by transesophageal Doppler echocardiography: Effect of different loading conditions
    • Nishimura RA, Abel MD, Hatle LK, Tajik AJ. Relation of pulmonary vein to mitral flow velocities by transesophageal Doppler echocardiography: effect of different loading conditions. Circulation 1990;81:1488-97.
    • (1990) Circulation , vol.81 , pp. 1488-1497
    • Nishimura, R.A.1    Abel, M.D.2    Hatle, L.K.3    Tajik, A.J.4
  • 9
    • 0032862581 scopus 로고    scopus 로고
    • ASE/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiography examination
    • Shanewise JS, Cheung AT, Aronson S, et al. ASE/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiography examination: recommendations of the American Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. Anesth Analg 1999; 89:870-84.
    • (1999) Anesth Analg , vol.89 , pp. 870-884
    • Shanewise, J.S.1    Cheung, A.T.2    Aronson, S.3
  • 10
    • 0025804317 scopus 로고
    • Intraoperative estimation of cardiac output by transesophageal pulsed Doppler echocardiography
    • Muhiudeen IA, Kuecherer HF, Lee E, et al. Intraoperative estimation of cardiac output by transesophageal pulsed Doppler echocardiography. Anesthesiology 1991;74:9-14.
    • (1991) Anesthesiology , vol.74 , pp. 9-14
    • Muhiudeen, I.A.1    Kuecherer, H.F.2    Lee, E.3
  • 11
    • 0025983726 scopus 로고
    • Measurement of pulmonary blood flow with transesophageal two-dimensional and Doppler echocardiography
    • Savino JS, Troianos CA, Aukburg S, et al. Measurement of pulmonary blood flow with transesophageal two-dimensional and Doppler echocardiography. Anesthesiology 1991;75:445-51.
    • (1991) Anesthesiology , vol.75 , pp. 445-451
    • Savino, J.S.1    Troianos, C.A.2    Aukburg, S.3
  • 12
    • 0026641991 scopus 로고
    • Transoesophageal pulsed wave Doppler measurement of cardiac output during major vascular surgery: Comparison with the thermodilution technique
    • Ryan T, Page R, Bouchier-Hayes D, Cunningham AJ. Transoesophageal pulsed wave Doppler measurement of cardiac output during major vascular surgery: comparison with the thermodilution technique. Br J Anaesth 1992;69:101-4.
    • (1992) Br J Anaesth , vol.69 , pp. 101-104
    • Ryan, T.1    Page, R.2    Bouchier-Hayes, D.3    Cunningham, A.J.4
  • 13
    • 0028355287 scopus 로고
    • Cardiac output by transesophageal echocardiography using continuous-wave Doppler across the aortic valve
    • Darmon PL, Hillel Z, Mogtader A, et al. Cardiac output by transesophageal echocardiography using continuous-wave Doppler across the aortic valve. Anesthesiology 1994;80: 796-805.
    • (1994) Anesthesiology , vol.80 , pp. 796-805
    • Darmon, P.L.1    Hillel, Z.2    Mogtader, A.3
  • 14
    • 0345131662 scopus 로고    scopus 로고
    • Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: A comparison to thermodilution
    • Perrino AC Jr, Harris SN, Luther MA. Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: a comparison to thermodilution. Anesthesiology 1998;89:350-7.
    • (1998) Anesthesiology , vol.89 , pp. 350-357
    • Perrino Jr., A.C.1    Harris, S.N.2    Luther, M.A.3
  • 15
    • 0029362422 scopus 로고
    • Quantitative measurement of volume flow rate (cardiac output) by the multibeam Doppler method
    • Tsujino H, Shiki E, Hirama M, Iinuma K. Quantitative measurement of volume flow rate (cardiac output) by the multibeam Doppler method. J Am Soc Echocardiogr 1995;8:621-30.
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 621-630
    • Tsujino, H.1    Shiki, E.2    Hirama, M.3    Iinuma, K.4
  • 16
    • 8044260000 scopus 로고    scopus 로고
    • Automated cardiac output measurement by spatiotemporal integration of color Doppler dada: In vitro and clinical validation
    • Sun JP, Pu M, Fouad FM, et al. Automated cardiac output measurement by spatiotemporal integration of color Doppler dada: in vitro and clinical validation. Circulation 1997;95:932-9.
    • (1997) Circulation , vol.95 , pp. 932-939
    • Sun, J.P.1    Pu, M.2    Fouad, F.M.3
  • 17
    • 0032190619 scopus 로고    scopus 로고
    • Quantification of mitral regurgitation by automated cardiac output measurement: Experimental and clinical validation
    • Sun JP, Yang XS, Qin JX, et al. Quantification of mitral regurgitation by automated cardiac output measurement: experimental and clinical validation. J Am Coll Cardiol 1998;32:1074-82.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1074-1082
    • Sun, J.P.1    Yang, X.S.2    Qin, J.X.3
  • 18
    • 0031795416 scopus 로고    scopus 로고
    • Automatic cardiac output measurement (ACOM): Clinical applications of a new noninvasive tool
    • Trindade PT, Brown P, Puryear JP, et al. Automatic cardiac output measurement (ACOM): clinical applications of a new noninvasive tool. Int J Card Imaging 1998;14:147-57.
    • (1998) Int J Card Imaging , vol.14 , pp. 147-157
    • Trindade, P.T.1    Brown, P.2    Puryear, J.P.3
  • 19
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 20
    • 0020676669 scopus 로고
    • The effect of variations of pulsed Doppler sampling site on calculation of cardiac output: An experimental study in open-chest dogs
    • Fisher DC, Sahn DJ, Friedman MJ, et al. The effect of variations of pulsed Doppler sampling site on calculation of cardiac output: an experimental study in open-chest dogs. Circulation 1983;67:370-6.
    • (1983) Circulation , vol.67 , pp. 370-376
    • Fisher, D.C.1    Sahn, D.J.2    Friedman, M.J.3
  • 21
    • 0021314242 scopus 로고
    • Doppler echocardiographic measurement of cardiac output: Comparison with a non-golden standard
    • Schuster AH, Nanda NC. Doppler echocardiographic measurement of cardiac output: comparison with a non-golden standard. Am J Cardiol 1984;53:257-9.
    • (1984) Am J Cardiol , vol.53 , pp. 257-259
    • Schuster, A.H.1    Nanda, N.C.2
  • 22
    • 0030730222 scopus 로고    scopus 로고
    • Automated assessment of mitral regurgitant volume and regurgitant fraction by a newly developed digital color Doppler velocity profile integration method
    • Hozumi T, Yoshida K, Akasaka T, et al. Automated assessment of mitral regurgitant volume and regurgitant fraction by a newly developed digital color Doppler velocity profile integration method. Am J Cardiol 1997;80:1325-30.
    • (1997) Am J Cardiol , vol.80 , pp. 1325-1330
    • Hozumi, T.1    Yoshida, K.2    Akasaka, T.3
  • 23
    • 0036839645 scopus 로고    scopus 로고
    • Automated quantification of aortic regurgitant volume and regurgitant fraction using the digital colour Doppler velocity profile integration method in patients with aortic regurgitation
    • Miyake Y, Hozumi T, Mori I, et al. Automated quantification of aortic regurgitant volume and regurgitant fraction using the digital colour Doppler velocity profile integration method in patients with aortic regurgitation. Heart 2002;88:481-4.
    • (2002) Heart , vol.88 , pp. 481-484
    • Miyake, Y.1    Hozumi, T.2    Mori, I.3
  • 24
    • 0027137477 scopus 로고
    • Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass
    • Latson TW, Whitten CW, O'Flaherty D. Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass. Anesthesiology 1993;79:1233-43.ting, M.D., and sponsored by the PSEF and the ASAPS. CME credit (7 hours) is subject to final program development.
    • (1993) Anesthesiology , vol.79 , pp. 1233-1243
    • Latson, T.W.1    Whitten, C.W.2    O'Flaherty, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.