메뉴 건너뛰기




Volumn 19, Issue 3, 2004, Pages 369-372

Measuring flexion in knee arthroplasty patients

Author keywords

Goniometer; Knee arthroplasty; Knee flexion

Indexed keywords

ACCURACY; ANALYTIC METHOD; ANALYTICAL ERROR; ARTICLE; BODY MASS; CLINICAL ARTICLE; CORRELATION COEFFICIENT; GONIOMETRY; HUMAN; INTERMETHOD COMPARISON; KNEE ARTHROPLASTY; KNEE FUNCTION; KNEE RADIOGRAPHY; LEG; PHYSICAL EXAMINATION;

EID: 1942453874     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2003.12.001     Document Type: Article
Times cited : (102)

References (13)
  • 1
    • 84892033603 scopus 로고
    • Patient outcomes following tricompartmental total knee replacement: A meta-analysis
    • Callahan C.M., Drake B.G., Heck D.A., et al. Patient outcomes following tricompartmental total knee replacement a meta-analysis. JAMA. 271:1994;1349.
    • (1994) JAMA , vol.271 , pp. 1349
    • Callahan, C.M.1    Drake, B.G.2    Heck, D.A.3
  • 2
    • 0031661292 scopus 로고    scopus 로고
    • Range of motion after total knee arthroplasty the effect of implant design and weight-bearing conditions
    • Dennis D.A., Komistek R.D., Stiehl J.B., et al. Range of motion after total knee arthroplasty the effect of implant design and weight-bearing conditions. J Arthroplasty. 13:1998;748.
    • (1998) J Arthroplasty , vol.13 , pp. 748
    • Dennis, D.A.1    Komistek, R.D.2    Stiehl, J.B.3
  • 3
    • 0015266003 scopus 로고
    • A quantative analysis of knee motion during activities of daily living
    • Lubenthal K.N., Smidt G.L., Kettlekamb D.B. A quantative analysis of knee motion during activities of daily living. Phys Ther. 52:1972;34.
    • (1972) Phys Ther , vol.52 , pp. 34
    • Lubenthal, K.N.1    Smidt, G.L.2    Kettlekamb, D.B.3
  • 4
    • 0035045059 scopus 로고    scopus 로고
    • Sequential bilateral total knee arthroplasty under one anesthetic in patients over 75 years old
    • Adili A., Bhandari M., Petruccelli D., et al. Sequential bilateral total knee arthroplasty under one anesthetic in patients over 75 years old. J Arthroplasty. 16:2001;271.
    • (2001) J Arthroplasty , vol.16 , pp. 271
    • Adili, A.1    Bhandari, M.2    Petruccelli, D.3
  • 5
    • 0035208794 scopus 로고    scopus 로고
    • Midterm clinical and radiographic results with the Genesis I total knee prosthesis
    • Chen A.L., Mujtaba M., Zuckerman J.D., et al. Midterm clinical and radiographic results with the Genesis I total knee prosthesis. J Arthroplasty. 16:2001;1055.
    • (2001) J Arthroplasty , vol.16 , pp. 1055
    • Chen, A.L.1    Mujtaba, M.2    Zuckerman, J.D.3
  • 6
    • 0034983927 scopus 로고    scopus 로고
    • Posterior cruciate-sacrificing versus posterior cruciate-substituting total knee arthroplasty
    • Title C.I., Rodriguez J.A., Ranawat C.S. Posterior cruciate-sacrificing versus posterior cruciate-substituting total knee arthroplasty. J Arthroplasty. 16:2001;409.
    • (2001) J Arthroplasty , vol.16 , pp. 409
    • Title, C.I.1    Rodriguez, J.A.2    Ranawat, C.S.3
  • 7
    • 0023096476 scopus 로고
    • Reliability and validity of goniometric measurements at the knee
    • Gogia P.P., Braatz J.H., Rose S.J., et al. Reliability and validity of goniometric measurements at the knee. Phys Ther Res. 67:1987;192.
    • (1987) Phys Ther Res , vol.67 , pp. 192
    • Gogia, P.P.1    Braatz, J.H.2    Rose, S.J.3
  • 8
    • 0031296751 scopus 로고    scopus 로고
    • Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects
    • Brosseau L., Tousignant M., Budd J., et al. Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects. Physio Res Intl. 2:1997;150.
    • (1997) Physio Res Intl , vol.2 , pp. 150
    • Brosseau, L.1    Tousignant, M.2    Budd, J.3
  • 9
    • 0021368263 scopus 로고
    • Goiniometric measurement reliability in physical medicine
    • Mayerson N.H., Milano R.N. Goiniometric measurement reliability in physical medicine. Arch Phys Med Rehab. 65:1984;92.
    • (1984) Arch Phys Med Rehab , vol.65 , pp. 92
    • Mayerson, N.H.1    Milano, R.N.2
  • 10
    • 0020514697 scopus 로고
    • Goniometric reliability in a clinical setting; Elbow and knee measurements
    • Rothstein J.M., Miller P.J., Roettger R.F. Goniometric reliability in a clinical setting; elbow and knee measurements. Phys Ther. 63:1983;1611.
    • (1983) Phys Ther , vol.63 , pp. 1611
    • Rothstein, J.M.1    Miller, P.J.2    Roettger, R.F.3
  • 11
    • 0026058416 scopus 로고
    • Reliability of goniometric and visual estimates of knee range of motion obtained in a clinical setting
    • Watkins M.A., Riddle D.L., Lamb R.L., et al. Reliability of goniometric and visual estimates of knee range of motion obtained in a clinical setting. Phys Ther. 71:1991;90.
    • (1991) Phys Ther , vol.71 , pp. 90
    • Watkins, M.A.1    Riddle, D.L.2    Lamb, R.L.3
  • 12
    • 0018124634 scopus 로고
    • Reliability of goniometric measurements
    • Boone D.C., Azen S.P., Lin C.M., et al. Reliability of goniometric measurements. Phys Ther. 58:1978;1355.
    • (1978) Phys Ther , vol.58 , pp. 1355
    • Boone, D.C.1    Azen, S.P.2    Lin, C.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.