메뉴 건너뛰기




Volumn 22, Issue 3, 2004, Pages 329-343

Imaging freely moving subjects using continuous interleaved orthogonal magnetic resonance imaging

Author keywords

Continuous imaging; Dynamic imaging; Fetal imaging; Real time MRI

Indexed keywords

ARTICLE; DIAGNOSTIC ACCURACY; ENVIRONMENTAL FACTOR; FETUS DEVELOPMENT; IMAGING; LIQUID; MATHEMATICAL ANALYSIS; MATHEMATICAL COMPUTING; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 1942420758     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0730-725X(03)00184-X     Document Type: Article
Times cited : (8)

References (24)
  • 2
    • 0025991499 scopus 로고
    • Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
    • Stehling M.K., Turner R., Mansfield P. Echo-Planar Imaging Magnetic Resonance Imaging in a Fraction of a Second. Science. 254:1991;43-50.
    • (1991) Science , vol.254 , pp. 43-50
    • Stehling, M.K.1    Turner, R.2    Mansfield, P.3
  • 6
    • 0029678044 scopus 로고    scopus 로고
    • Fetal Intracerebral. Hemorrhage in the second trimester: Diagnosis by sonography and magnetic resonance imaging
    • Reiss I., Gortner L., Moller J., Gehl H., Baschat A., Gembruch U. Fetal Intracerebral. Hemorrhage in the second trimester diagnosis by sonography and magnetic resonance imaging. Ultrasound Obstet Gynecol. 7:1996;49-51.
    • (1996) Ultrasound Obstet Gynecol , vol.7 , pp. 49-51
    • Reiss, I.1    Gortner, L.2    Moller, J.3    Gehl, H.4    Baschat, A.5    Gembruch, U.6
  • 8
    • 0032750912 scopus 로고    scopus 로고
    • Complex Fetal Disorders: Effect of MR Imaging on Management-Preliminary Clinical Experience
    • Coakley F.V., Hricak H., Filly R.A., Barkovich A.J., Harrison M.R. Complex Fetal Disorders Effect of MR Imaging on Management-Preliminary Clinical Experience. Radiology. 213:1999;691-696.
    • (1999) Radiology , vol.213 , pp. 691-696
    • Coakley, F.V.1    Hricak, H.2    Filly, R.A.3    Barkovich, A.J.4    Harrison, M.R.5
  • 14
    • 0027313206 scopus 로고
    • Patellofemoral Joint: Identification of Abnormalities with Active-Movement, "unloaded" versus "loaded" Kinematic MR imaging techniques
    • Shellock F.G., Mink J.H., Deutsch A.L., Foo T.K., Sullenberger P. Patellofemoral Joint Identification of Abnormalities with Active-Movement, "Unloaded" versus "Loaded" Kinematic MR imaging techniques. Radiology. 188:1993;575-578.
    • (1993) Radiology , vol.188 , pp. 575-578
    • Shellock, F.G.1    Mink, J.H.2    Deutsch, A.L.3    Foo, T.K.4    Sullenberger, P.5
  • 16
    • 0032866250 scopus 로고    scopus 로고
    • MR fluoroscopy using projection reconstruction multi-gradient-echo (prMGE) MRI
    • Rasche V., Holz D., Proksa R. MR fluoroscopy using projection reconstruction multi-gradient-echo (prMGE) MRI. Magnetic Resonance in Medicine. 42:1999;324-334.
    • (1999) Magnetic Resonance in Medicine , vol.42 , pp. 324-334
    • Rasche, V.1    Holz, D.2    Proksa, R.3
  • 17
    • 0034214892 scopus 로고    scopus 로고
    • Real time image reconstruction for spiral MRI using fixed-point calculation
    • Liao J.R. Real time image reconstruction for spiral MRI using fixed-point calculation. IEEE Transactions on Medical Imaging. 19:2000;690-698.
    • (2000) IEEE Transactions on Medical Imaging , vol.19 , pp. 690-698
    • Liao, J.R.1
  • 21
    • 0036339230 scopus 로고    scopus 로고
    • Kinematics of the buccal mass during swallowing based on magnetic resonance imaging in intact, behaving Aplysia californica
    • Neustadter DM, Drushel RF, Chiel HJ. Kinematics of the buccal mass during swallowing based on magnetic resonance imaging in intact, behaving Aplysia californica. J Exp Biol 2002;205:939-58.
    • (2002) J Exp Biol , vol.205 , pp. 939-58
    • Neustadter, D.M.1    Drushel, R.F.2    Chiel, H.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.