메뉴 건너뛰기




Volumn 31, Issue 4, 2005, Pages 718-724

Comparison of posterior capsule opacification rates between hydrophilic and hydrophobic single-piece acrylic intraocular lenses

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CATARACT; CLINICAL TRIAL; COMORBIDITY; COMPUTER PROGRAM; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; EPITHELIUM CELL; FOLLOW UP; HUMAN; HYDROPHILICITY; HYDROPHOBICITY; MAJOR CLINICAL STUDY; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL;

EID: 19344372456     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2004.08.060     Document Type: Article
Times cited : (82)

References (28)
  • 1
    • 0033772907 scopus 로고    scopus 로고
    • Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges
    • O. Nishi, K. Nishi, and K. Wickström Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges J Cataract Refract Surg 26 2000 1543 1549
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1543-1549
    • Nishi, O.1    Nishi, K.2    Wickström, K.3
  • 2
    • 0033968119 scopus 로고    scopus 로고
    • Surgical prevention of posterior capsule opacification. Part 3: Intraocular lens optic barrier effect as a second line of defense
    • Q. Peng, N. Visessook, and D.J. Apple Surgical prevention of posterior capsule opacification. Part 3: intraocular lens optic barrier effect as a second line of defense J Cataract Refract Surg 26 2000 198 213
    • (2000) J Cataract Refract Surg , vol.26 , pp. 198-213
    • Peng, Q.1    Visessook, N.2    Apple, D.J.3
  • 3
    • 0041355232 scopus 로고    scopus 로고
    • Posterior capsule opacification: Comparison of 3 intraocular lenses of different materials and design
    • G. Wejde, M. Kugelberg, and C. Zetterström Posterior capsule opacification: comparison of 3 intraocular lenses of different materials and design J Cataract Refract Surg 29 2003 1556 1559
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1556-1559
    • Wejde, G.1    Kugelberg, M.2    Zetterström, C.3
  • 5
    • 0036142525 scopus 로고    scopus 로고
    • Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses
    • C. Abela-Formanek, M. Amon, and G. Schild Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses J Cataract Refract Surg 28 2002 50 61
    • (2002) J Cataract Refract Surg , vol.28 , pp. 50-61
    • Abela-Formanek, C.1    Amon, M.2    Schild, G.3
  • 6
    • 0035115010 scopus 로고    scopus 로고
    • Biocompatibility of intraocular lenses
    • M. Amon Biocompatibility of intraocular lenses [letter] J Cataract Refract Surg 27 2001 178 179
    • (2001) J Cataract Refract Surg , vol.27 , pp. 178-179
    • Amon, M.1
  • 7
    • 0032779836 scopus 로고    scopus 로고
    • Surface cytologic features on intraocular lenses; Can increased biocompatibility have disadvantages?
    • E.J. Hollick, D.J. Spalton, and P.G. Ursell Surface cytologic features on intraocular lenses; can increased biocompatibility have disadvantages? Arch Ophthalmol 117 1999 872 878
    • (1999) Arch Ophthalmol , vol.117 , pp. 872-878
    • Hollick, E.J.1    Spalton, D.J.2    Ursell, P.G.3
  • 8
    • 0031899326 scopus 로고    scopus 로고
    • Relationship between intraocular lens biomaterials and posterior capsule opacification
    • P.G. Ursell, D.J. Spalton, and M.V. Pande Relationship between intraocular lens biomaterials and posterior capsule opacification J Cataract Refract Surg 24 1998 352 360
    • (1998) J Cataract Refract Surg , vol.24 , pp. 352-360
    • Ursell, P.G.1    Spalton, D.J.2    Pande, M.V.3
  • 9
    • 0942268753 scopus 로고    scopus 로고
    • Posterior capsule opacification after implantation of a hydrogel intraocular lens
    • K. Hayashi, and H. Hayashi Posterior capsule opacification after implantation of a hydrogel intraocular lens Br J Ophthalmol 88 2004 182 185
    • (2004) Br J Ophthalmol , vol.88 , pp. 182-185
    • Hayashi, K.1    Hayashi, H.2
  • 10
    • 0036215026 scopus 로고    scopus 로고
    • Relationship of AcrySof acrylic and PhacoFlex silicone intraocular lenses to visual acuity and posterior capsule opacification
    • M.T. Halpern, D. Covert, and C. Battista Relationship of AcrySof acrylic and PhacoFlex silicone intraocular lenses to visual acuity and posterior capsule opacification J Cataract Refract Surg 28 2002 662 669
    • (2002) J Cataract Refract Surg , vol.28 , pp. 662-669
    • Halpern, M.T.1    Covert, D.2    Battista, C.3
  • 11
    • 0042357062 scopus 로고    scopus 로고
    • Posterior capsule opacification and neodymium:YAG capsulotomy rates with AcrySof acrylic and PhacoFlex II silicone intraocular lenses
    • P.H. Ernest Posterior capsule opacification and neodymium:YAG capsulotomy rates with AcrySof acrylic and PhacoFlex II silicone intraocular lenses J Cataract Refract Surg 29 2003 1546 1550
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1546-1550
    • Ernest, P.H.1
  • 12
    • 0041856088 scopus 로고    scopus 로고
    • Posterior capsule opacification after phacoemulsification; Silicone CeeOn Edge versus acrylate AcrySof intraocular lens
    • G. Prosdocimo, G. Tassinari, and M. Sala Posterior capsule opacification after phacoemulsification; silicone CeeOn Edge versus acrylate AcrySof intraocular lens J Cataract Refract Surg 29 2003 1551 1555
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1551-1555
    • Prosdocimo, G.1    Tassinari, G.2    Sala, M.3
  • 13
    • 0031456846 scopus 로고    scopus 로고
    • High-resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery
    • M.V. Pande, P.G. Ursell, and D.J. Spalton High-resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery J Cataract Refract Surg 23 1997 1521 1527
    • (1997) J Cataract Refract Surg , vol.23 , pp. 1521-1527
    • Pande, M.V.1    Ursell, P.G.2    Spalton, D.J.3
  • 14
    • 0033760066 scopus 로고    scopus 로고
    • Quantification of posterior capsular opacification in digital images after cataract surgery
    • S.A. Barman, E.J. Hollick, and J.F. Boyce Quantification of posterior capsular opacification in digital images after cataract surgery Invest Ophthalmol Vis Sci 41 2000 3882 3892
    • (2000) Invest Ophthalmol Vis Sci , vol.41 , pp. 3882-3892
    • Barman, S.A.1    Hollick, E.J.2    Boyce, J.F.3
  • 15
    • 0032827818 scopus 로고    scopus 로고
    • The effect of capsulorhexis size on posterior capsular opacification: One-year results of a randomized prospective trial
    • E.J. Hollick, D.J. Spalton, and W.R. Meacock The effect of capsulorhexis size on posterior capsular opacification: one-year results of a randomized prospective trial Am J Ophthalmol 128 1999 271 279
    • (1999) Am J Ophthalmol , vol.128 , pp. 271-279
    • Hollick, E.J.1    Spalton, D.J.2    Meacock, W.R.3
  • 16
    • 0034926360 scopus 로고    scopus 로고
    • The effect of polymethylmethacrylate and AcrySof intraocular lenses on the posterior capsule in patients with a large capsulorrhexis
    • W.R. Meacock, D.J. Spalton, and E.J. Hollick The effect of polymethylmethacrylate and AcrySof intraocular lenses on the posterior capsule in patients with a large capsulorrhexis Jpn J Ophthalmol 45 2001 348 354
    • (2001) Jpn J Ophthalmol , vol.45 , pp. 348-354
    • Meacock, W.R.1    Spalton, D.J.2    Hollick, E.J.3
  • 17
    • 0036062050 scopus 로고    scopus 로고
    • Uveal and capsular biocompatibility of 2 foldable acrylic intraocular lenses in patients with uveitis or pseudoexfoliation syndrome; Comparison to a control group
    • C. Abela-Formanek, M. Amon, and J. Schauersberger Uveal and capsular biocompatibility of 2 foldable acrylic intraocular lenses in patients with uveitis or pseudoexfoliation syndrome; comparison to a control group J Cataract Refract Surg 28 2002 1160 1172
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1160-1172
    • Abela-Formanek, C.1    Amon, M.2    Schauersberger, J.3
  • 18
    • 0034835577 scopus 로고    scopus 로고
    • Effect of intraocular lens haptic compressibility on the posterior lens capsule after cataract surgery
    • W.R. Meacock, and D.J. Spalton Effect of intraocular lens haptic compressibility on the posterior lens capsule after cataract surgery J Cataract Refract Surg 27 2001 1366 1371
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1366-1371
    • Meacock, W.R.1    Spalton, D.J.2
  • 19
    • 0034892704 scopus 로고    scopus 로고
    • Effect of optic size on posterior capsule opacification: 5.5 mm versus 6.0 mm AcrySof intraocular lenses
    • W.R. Meacock, D.J. Spalton, J.F. Boyce, and R.M. Jose Effect of optic size on posterior capsule opacification: 5.5 mm versus 6.0 mm AcrySof intraocular lenses J Cataract Refract Surg 27 2001 1194 1198
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1194-1198
    • Meacock, W.R.1    Spalton, D.J.2    Boyce, J.F.3    Jose, R.M.4
  • 20
    • 0036068597 scopus 로고    scopus 로고
    • Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge
    • J.M. Schmidbauer, M. Escobar-Gomez, and D.J. Apple Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge J Cataract Refract Surg 28 2002 1251 1255
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1251-1255
    • Schmidbauer, J.M.1    Escobar-Gomez, M.2    Apple, D.J.3
  • 21
    • 0036063755 scopus 로고    scopus 로고
    • Evaluation of 3 modern single-piece foldable intraocular lenses; Clinicopathological study of posterior capsule opacification in a rabbit model
    • L.G. Vargas, Q. Peng, and D.J. Apple Evaluation of 3 modern single-piece foldable intraocular lenses; clinicopathological study of posterior capsule opacification in a rabbit model J Cataract Refract Surg 28 2002 1241 1250
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1241-1250
    • Vargas, L.G.1    Peng, Q.2    Apple, D.J.3
  • 22
    • 0036067261 scopus 로고    scopus 로고
    • Failure of a discontinuous bend to prevent lens epithelial cell migration in vitro
    • G.S. Bhermi, D.J. Spalton, A.A. El-Osta, and J. Marshall Failure of a discontinuous bend to prevent lens epithelial cell migration in vitro J Cataract Refract Surg 28 2002 1256 1261
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1256-1261
    • Bhermi, G.S.1    Spalton, D.J.2    El-Osta, A.A.3    Marshall, J.4
  • 23
    • 0030824089 scopus 로고    scopus 로고
    • Effect of intraocular lens design on migration of lens epithelial cells onto the posterior capsule
    • T. Nagamoto, and G. Eguchi Effect of intraocular lens design on migration of lens epithelial cells onto the posterior capsule J Cataract Refract Surg 23 1997 866 872
    • (1997) J Cataract Refract Surg , vol.23 , pp. 866-872
    • Nagamoto, T.1    Eguchi, G.2
  • 24
    • 0029909183 scopus 로고    scopus 로고
    • Optic sharp edge or convexity: Comparison of effects on posterior capsular opacification
    • T. Nagata, and I. Watanabe Optic sharp edge or convexity: comparison of effects on posterior capsular opacification Jpn J Ophthalmol 40 1996 397 403
    • (1996) Jpn J Ophthalmol , vol.40 , pp. 397-403
    • Nagata, T.1    Watanabe, I.2
  • 25
    • 0032913224 scopus 로고    scopus 로고
    • Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule
    • O. Nishi, and K. Nishi Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule J Cataract Refract Surg 25 1999 521 526
    • (1999) J Cataract Refract Surg , vol.25 , pp. 521-526
    • Nishi, O.1    Nishi, K.2
  • 26
    • 0036799726 scopus 로고    scopus 로고
    • Mathematical modeling of the forces between an intraocular lens and the capsule
    • J.F. Boyce, G.S. Bhermi, D.J. Spalton, and A.R. El-Osta Mathematical modeling of the forces between an intraocular lens and the capsule J Cataract Refract Surg 28 2002 1853 1859
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1853-1859
    • Boyce, J.F.1    Bhermi, G.S.2    Spalton, D.J.3    El-Osta, A.R.4
  • 27
    • 0037349443 scopus 로고    scopus 로고
    • Predicting posterior capsule opacification; Value of early retroillumination imaging
    • L.E. Bender, D.J. Spalton, and W. Meacock Predicting posterior capsule opacification; value of early retroillumination imaging J Cataract Refract Surg 29 2003 526 531
    • (2003) J Cataract Refract Surg , vol.29 , pp. 526-531
    • Bender, L.E.1    Spalton, D.J.2    Meacock, W.3
  • 28
    • 0041355224 scopus 로고    scopus 로고
    • Implantation of a single-piece, hydrophilic, acrylic, minus-power foldable posterior chamber intraocular lens in a rabbit model: Clinicopathologic study of posterior capsule opacification
    • L.G. Vargas, A.M. Izak, and D.J. Apple Implantation of a single-piece, hydrophilic, acrylic, minus-power foldable posterior chamber intraocular lens in a rabbit model: clinicopathologic study of posterior capsule opacification J Cataract Refract Surg 29 2003 1613 1620
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1613-1620
    • Vargas, L.G.1    Izak, A.M.2    Apple, D.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.