1
-
-
0033772907
-
Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges
-
O. Nishi, K. Nishi, and K. Wickström Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges J Cataract Refract Surg 26 2000 1543 1549
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 1543-1549
-
-
Nishi, O.1
Nishi, K.2
Wickström, K.3
-
2
-
-
0033968119
-
Surgical prevention of posterior capsule opacification. Part 3: Intraocular lens optic barrier effect as a second line of defense
-
Q. Peng, N. Visessook, and D.J. Apple Surgical prevention of posterior capsule opacification. Part 3: intraocular lens optic barrier effect as a second line of defense J Cataract Refract Surg 26 2000 198 213
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 198-213
-
-
Peng, Q.1
Visessook, N.2
Apple, D.J.3
-
3
-
-
0041355232
-
Posterior capsule opacification: Comparison of 3 intraocular lenses of different materials and design
-
G. Wejde, M. Kugelberg, and C. Zetterström Posterior capsule opacification: comparison of 3 intraocular lenses of different materials and design J Cataract Refract Surg 29 2003 1556 1559
-
(2003)
J Cataract Refract Surg
, vol.29
, pp. 1556-1559
-
-
Wejde, G.1
Kugelberg, M.2
Zetterström, C.3
-
5
-
-
0036142525
-
Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses
-
C. Abela-Formanek, M. Amon, and G. Schild Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses J Cataract Refract Surg 28 2002 50 61
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 50-61
-
-
Abela-Formanek, C.1
Amon, M.2
Schild, G.3
-
6
-
-
0035115010
-
Biocompatibility of intraocular lenses
-
M. Amon Biocompatibility of intraocular lenses [letter] J Cataract Refract Surg 27 2001 178 179
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 178-179
-
-
Amon, M.1
-
7
-
-
0032779836
-
Surface cytologic features on intraocular lenses; Can increased biocompatibility have disadvantages?
-
E.J. Hollick, D.J. Spalton, and P.G. Ursell Surface cytologic features on intraocular lenses; can increased biocompatibility have disadvantages? Arch Ophthalmol 117 1999 872 878
-
(1999)
Arch Ophthalmol
, vol.117
, pp. 872-878
-
-
Hollick, E.J.1
Spalton, D.J.2
Ursell, P.G.3
-
8
-
-
0031899326
-
Relationship between intraocular lens biomaterials and posterior capsule opacification
-
P.G. Ursell, D.J. Spalton, and M.V. Pande Relationship between intraocular lens biomaterials and posterior capsule opacification J Cataract Refract Surg 24 1998 352 360
-
(1998)
J Cataract Refract Surg
, vol.24
, pp. 352-360
-
-
Ursell, P.G.1
Spalton, D.J.2
Pande, M.V.3
-
9
-
-
0942268753
-
Posterior capsule opacification after implantation of a hydrogel intraocular lens
-
K. Hayashi, and H. Hayashi Posterior capsule opacification after implantation of a hydrogel intraocular lens Br J Ophthalmol 88 2004 182 185
-
(2004)
Br J Ophthalmol
, vol.88
, pp. 182-185
-
-
Hayashi, K.1
Hayashi, H.2
-
10
-
-
0036215026
-
Relationship of AcrySof acrylic and PhacoFlex silicone intraocular lenses to visual acuity and posterior capsule opacification
-
M.T. Halpern, D. Covert, and C. Battista Relationship of AcrySof acrylic and PhacoFlex silicone intraocular lenses to visual acuity and posterior capsule opacification J Cataract Refract Surg 28 2002 662 669
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 662-669
-
-
Halpern, M.T.1
Covert, D.2
Battista, C.3
-
11
-
-
0042357062
-
Posterior capsule opacification and neodymium:YAG capsulotomy rates with AcrySof acrylic and PhacoFlex II silicone intraocular lenses
-
P.H. Ernest Posterior capsule opacification and neodymium:YAG capsulotomy rates with AcrySof acrylic and PhacoFlex II silicone intraocular lenses J Cataract Refract Surg 29 2003 1546 1550
-
(2003)
J Cataract Refract Surg
, vol.29
, pp. 1546-1550
-
-
Ernest, P.H.1
-
12
-
-
0041856088
-
Posterior capsule opacification after phacoemulsification; Silicone CeeOn Edge versus acrylate AcrySof intraocular lens
-
G. Prosdocimo, G. Tassinari, and M. Sala Posterior capsule opacification after phacoemulsification; silicone CeeOn Edge versus acrylate AcrySof intraocular lens J Cataract Refract Surg 29 2003 1551 1555
-
(2003)
J Cataract Refract Surg
, vol.29
, pp. 1551-1555
-
-
Prosdocimo, G.1
Tassinari, G.2
Sala, M.3
-
13
-
-
0031456846
-
High-resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery
-
M.V. Pande, P.G. Ursell, and D.J. Spalton High-resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery J Cataract Refract Surg 23 1997 1521 1527
-
(1997)
J Cataract Refract Surg
, vol.23
, pp. 1521-1527
-
-
Pande, M.V.1
Ursell, P.G.2
Spalton, D.J.3
-
14
-
-
0033760066
-
Quantification of posterior capsular opacification in digital images after cataract surgery
-
S.A. Barman, E.J. Hollick, and J.F. Boyce Quantification of posterior capsular opacification in digital images after cataract surgery Invest Ophthalmol Vis Sci 41 2000 3882 3892
-
(2000)
Invest Ophthalmol Vis Sci
, vol.41
, pp. 3882-3892
-
-
Barman, S.A.1
Hollick, E.J.2
Boyce, J.F.3
-
15
-
-
0032827818
-
The effect of capsulorhexis size on posterior capsular opacification: One-year results of a randomized prospective trial
-
E.J. Hollick, D.J. Spalton, and W.R. Meacock The effect of capsulorhexis size on posterior capsular opacification: one-year results of a randomized prospective trial Am J Ophthalmol 128 1999 271 279
-
(1999)
Am J Ophthalmol
, vol.128
, pp. 271-279
-
-
Hollick, E.J.1
Spalton, D.J.2
Meacock, W.R.3
-
16
-
-
0034926360
-
The effect of polymethylmethacrylate and AcrySof intraocular lenses on the posterior capsule in patients with a large capsulorrhexis
-
W.R. Meacock, D.J. Spalton, and E.J. Hollick The effect of polymethylmethacrylate and AcrySof intraocular lenses on the posterior capsule in patients with a large capsulorrhexis Jpn J Ophthalmol 45 2001 348 354
-
(2001)
Jpn J Ophthalmol
, vol.45
, pp. 348-354
-
-
Meacock, W.R.1
Spalton, D.J.2
Hollick, E.J.3
-
17
-
-
0036062050
-
Uveal and capsular biocompatibility of 2 foldable acrylic intraocular lenses in patients with uveitis or pseudoexfoliation syndrome; Comparison to a control group
-
C. Abela-Formanek, M. Amon, and J. Schauersberger Uveal and capsular biocompatibility of 2 foldable acrylic intraocular lenses in patients with uveitis or pseudoexfoliation syndrome; comparison to a control group J Cataract Refract Surg 28 2002 1160 1172
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1160-1172
-
-
Abela-Formanek, C.1
Amon, M.2
Schauersberger, J.3
-
18
-
-
0034835577
-
Effect of intraocular lens haptic compressibility on the posterior lens capsule after cataract surgery
-
W.R. Meacock, and D.J. Spalton Effect of intraocular lens haptic compressibility on the posterior lens capsule after cataract surgery J Cataract Refract Surg 27 2001 1366 1371
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 1366-1371
-
-
Meacock, W.R.1
Spalton, D.J.2
-
19
-
-
0034892704
-
Effect of optic size on posterior capsule opacification: 5.5 mm versus 6.0 mm AcrySof intraocular lenses
-
W.R. Meacock, D.J. Spalton, J.F. Boyce, and R.M. Jose Effect of optic size on posterior capsule opacification: 5.5 mm versus 6.0 mm AcrySof intraocular lenses J Cataract Refract Surg 27 2001 1194 1198
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 1194-1198
-
-
Meacock, W.R.1
Spalton, D.J.2
Boyce, J.F.3
Jose, R.M.4
-
20
-
-
0036068597
-
Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge
-
J.M. Schmidbauer, M. Escobar-Gomez, and D.J. Apple Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge J Cataract Refract Surg 28 2002 1251 1255
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1251-1255
-
-
Schmidbauer, J.M.1
Escobar-Gomez, M.2
Apple, D.J.3
-
21
-
-
0036063755
-
Evaluation of 3 modern single-piece foldable intraocular lenses; Clinicopathological study of posterior capsule opacification in a rabbit model
-
L.G. Vargas, Q. Peng, and D.J. Apple Evaluation of 3 modern single-piece foldable intraocular lenses; clinicopathological study of posterior capsule opacification in a rabbit model J Cataract Refract Surg 28 2002 1241 1250
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1241-1250
-
-
Vargas, L.G.1
Peng, Q.2
Apple, D.J.3
-
22
-
-
0036067261
-
Failure of a discontinuous bend to prevent lens epithelial cell migration in vitro
-
G.S. Bhermi, D.J. Spalton, A.A. El-Osta, and J. Marshall Failure of a discontinuous bend to prevent lens epithelial cell migration in vitro J Cataract Refract Surg 28 2002 1256 1261
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1256-1261
-
-
Bhermi, G.S.1
Spalton, D.J.2
El-Osta, A.A.3
Marshall, J.4
-
23
-
-
0030824089
-
Effect of intraocular lens design on migration of lens epithelial cells onto the posterior capsule
-
T. Nagamoto, and G. Eguchi Effect of intraocular lens design on migration of lens epithelial cells onto the posterior capsule J Cataract Refract Surg 23 1997 866 872
-
(1997)
J Cataract Refract Surg
, vol.23
, pp. 866-872
-
-
Nagamoto, T.1
Eguchi, G.2
-
24
-
-
0029909183
-
Optic sharp edge or convexity: Comparison of effects on posterior capsular opacification
-
T. Nagata, and I. Watanabe Optic sharp edge or convexity: comparison of effects on posterior capsular opacification Jpn J Ophthalmol 40 1996 397 403
-
(1996)
Jpn J Ophthalmol
, vol.40
, pp. 397-403
-
-
Nagata, T.1
Watanabe, I.2
-
25
-
-
0032913224
-
Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule
-
O. Nishi, and K. Nishi Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule J Cataract Refract Surg 25 1999 521 526
-
(1999)
J Cataract Refract Surg
, vol.25
, pp. 521-526
-
-
Nishi, O.1
Nishi, K.2
-
26
-
-
0036799726
-
Mathematical modeling of the forces between an intraocular lens and the capsule
-
J.F. Boyce, G.S. Bhermi, D.J. Spalton, and A.R. El-Osta Mathematical modeling of the forces between an intraocular lens and the capsule J Cataract Refract Surg 28 2002 1853 1859
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1853-1859
-
-
Boyce, J.F.1
Bhermi, G.S.2
Spalton, D.J.3
El-Osta, A.R.4
-
27
-
-
0037349443
-
Predicting posterior capsule opacification; Value of early retroillumination imaging
-
L.E. Bender, D.J. Spalton, and W. Meacock Predicting posterior capsule opacification; value of early retroillumination imaging J Cataract Refract Surg 29 2003 526 531
-
(2003)
J Cataract Refract Surg
, vol.29
, pp. 526-531
-
-
Bender, L.E.1
Spalton, D.J.2
Meacock, W.3
-
28
-
-
0041355224
-
Implantation of a single-piece, hydrophilic, acrylic, minus-power foldable posterior chamber intraocular lens in a rabbit model: Clinicopathologic study of posterior capsule opacification
-
L.G. Vargas, A.M. Izak, and D.J. Apple Implantation of a single-piece, hydrophilic, acrylic, minus-power foldable posterior chamber intraocular lens in a rabbit model: clinicopathologic study of posterior capsule opacification J Cataract Refract Surg 29 2003 1613 1620
-
(2003)
J Cataract Refract Surg
, vol.29
, pp. 1613-1620
-
-
Vargas, L.G.1
Izak, A.M.2
Apple, D.J.3
|