메뉴 건너뛰기




Volumn 51, Issue 5, 2005, Pages 1565-1568

Optical probe technique for two-phase flow measurements in an extraction column

Author keywords

[No Author keywords available]

Indexed keywords

TWO-PHASE FLOW;

EID: 19344370316     PISSN: 00011541     EISSN: None     Source Type: Journal    
DOI: 10.1002/aic.10404     Document Type: Article
Times cited : (9)

References (16)
  • 1
    • 0345329522 scopus 로고    scopus 로고
    • A technical study on the Spraytec performances: Influence of multiple light scattering and multi-modal drop-size distribution measurements
    • Triballier K, Dumouchel C, Cousin J. A technical study on the Spraytec performances: influence of multiple light scattering and multi-modal drop-size distribution measurements, Experiments in Fluids. 2003, 35:347-356.
    • (2003) Experiments in Fluids , vol.35 , pp. 347-356
    • Triballier, K.1    Dumouchel, C.2    Cousin, J.3
  • 2
    • 0042120984 scopus 로고    scopus 로고
    • Residence time distribution of droplets within discs and doughnuts pulsed extraction columns via Lagrangian experiments and simulations
    • Bardin-Monnier N, Guiraud P, Gourdon C. Residence time distribution of droplets within discs and doughnuts pulsed extraction columns via Lagrangian experiments and simulations. Chem. Eng. J. 2003, 94:241-254.
    • (2003) Chem. Eng. J. , vol.94 , pp. 241-254
    • Bardin-Monnier, N.1    Guiraud, P.2    Gourdon, C.3
  • 3
    • 0031143124 scopus 로고    scopus 로고
    • Fluorescence capillary photometry for characterization of liquid-liquid dispersions
    • Weiss C, Kohler V, Marr R. Fluorescence capillary photometry for characterization of liquid-liquid dispersions. AIChE J. 1997, 43:1153-1162.
    • (1997) AIChE J. , vol.43 , pp. 1153-1162
    • Weiss, C.1    Kohler, V.2    Marr, R.3
  • 4
    • 0033082356 scopus 로고    scopus 로고
    • Simulation of hydrodynamic performance of stirred extraction column
    • Steiner L, Balmelli M, Hartland S. Simulation of hydrodynamic performance of stirred extraction column. AIChE J. 1999, 45:257-267.
    • (1999) AIChE J. , vol.45 , pp. 257-267
    • Steiner, L.1    Balmelli, M.2    Hartland, S.3
  • 5
    • 0028533449 scopus 로고
    • Holdup measurements in a Scheibel column by means of an ultrasonic technique
    • Bonnet JC, Sorrentino JA. Holdup measurements in a Scheibel column by means of an ultrasonic technique. J. of Chem. Technol. and Biotechnol. 1994, 61:201-207.
    • (1994) J. of Chem. Technol. and Biotechnol. , vol.61 , pp. 201-207
    • Bonnet, J.C.1    Sorrentino, J.A.2
  • 6
    • 19844364269 scopus 로고
    • The impedence method for dispersed phase holdup in solvent extractors
    • in Chinese
    • Bao X-J, Fan Z, Chen J-Y. The impedence method for dispersed phase holdup in solvent extractors. Petroleum Processing and Petrochem. Eng. 1994, 25:54-57 (in Chinese).
    • (1994) Petroleum Processing and Petrochem. Eng. , vol.25 , pp. 54-57
    • Bao, X.-J.1    Fan, Z.2    Chen, J.-Y.3
  • 7
    • 0001950573 scopus 로고
    • Interaction between bubbles and fibre optic probes in a bubble column
    • Chabot J, Lee S-L-P, Soria A, Lasa HI. Interaction between bubbles and fibre optic probes in a bubble column. C. J. of Chem. Eng. 1992, 70:61-68.
    • (1992) C. J. of Chem. Eng. , vol.70 , pp. 61-68
    • Chabot, J.1    Lee, S.-L.-P.2    Soria, A.3    Lasa, H.I.4
  • 10
    • 0035263858 scopus 로고    scopus 로고
    • Experimental study on bubble size distribution in there-phase circulating fluidized beds
    • Wang T-F, Wang J-F, Yang W-G, Jin Y. Experimental study on bubble size distribution in there-phase circulating fluidized beds. J. of Chem. Industry and Eng. (China). 2001, 52:197-203.
    • (2001) J. of Chem. Industry and Eng. (China) , vol.52 , pp. 197-203
    • Wang, T.-F.1    Wang, J.-F.2    Yang, W.-G.3    Jin, Y.4
  • 12
    • 0034283097 scopus 로고    scopus 로고
    • A dual optical probe for volume fraction, drop velocity and drop size measurements in liquid-liquid two-phase flow
    • Hamad F-A, Pierscionek B-K, Bruun H-H. A dual optical probe for volume fraction, drop velocity and drop size measurements in liquid-liquid two-phase flow. Measurement Sci. and Technol. 2000, 11:1307-1318.
    • (2000) Measurement Sci. and Technol. , vol.11 , pp. 1307-1318
    • Hamad, F.-A.1    Pierscionek, B.-K.2    Bruun, H.-H.3
  • 13
    • 0033853129 scopus 로고    scopus 로고
    • Mass transfer performance in a coales-cence-dispersion pulsed sieve plate extraction column
    • Li H-B, Luo G-S, Wang J-D. Mass transfer performance in a coales-cence-dispersion pulsed sieve plate extraction column. Chem. Eng. J. 2000, 78:225-229.
    • (2000) Chem. Eng. J. , vol.78 , pp. 225-229
    • Li, H.-B.1    Luo, G.-S.2    Wang, J.-D.3
  • 16
    • 0022537360 scopus 로고
    • Prediction of drop size in pulsed perforated-plate extraction columns
    • Kumar A, Hartland S. Prediction of drop size in pulsed perforated-plate extraction columns, Chem. Eng. Communications. 1986, 44:162-182.
    • (1986) Chem. Eng. Communications , vol.44 , pp. 162-182
    • Kumar, A.1    Hartland, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.