메뉴 건너뛰기




Volumn 24, Issue 5, 2005, Pages 549-556

Effect of pre-heat treatment on the static and dynamic thermo-mechanical properties of ultra-high molecular weight polyethylene

Author keywords

Degree of crystallinity; Dynamic mechanical properties; Micro hardness; Pre heat treatment; UHMWPE

Indexed keywords

BIOCOMPATIBILITY; CRYSTALLIZATION; ELASTIC MODULI; FRACTURE; HEAT TREATMENT; IMPLANTS (SURGICAL); JOINTS (ANATOMY); MICROHARDNESS; MOLECULAR WEIGHT; PROSTHETICS; THERMOMECHANICAL TREATMENT; VISCOELASTICITY;

EID: 19144368705     PISSN: 01429418     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.polymertesting.2005.02.007     Document Type: Article
Times cited : (69)

References (23)
  • 2
    • 0006894589 scopus 로고
    • Wear, creep and frictional heat of femoral implant articulating surface and the effect on long-term performance - Part 1, a - Review
    • J.A. Davidson, and C.J. Schwartz Wear, creep and frictional heat of femoral implant articulating surface and the effect on long-term performance - Part 1, A - review Journal of Biomedical Materials Research 21 1987 261
    • (1987) Journal of Biomedical Materials Research , vol.21 , pp. 261
    • Davidson, J.A.1    Schwartz, C.J.2
  • 3
    • 0038016670 scopus 로고    scopus 로고
    • Failure micro-mechanics during uniaxial tensile fracture of conventional and highly cross-linked ultra-high molecular weight polyethylenes used in total joint replacements
    • S.J. Gencur, C.M. Rimnac, and S.M. Kurtz Failure micro-mechanics during uniaxial tensile fracture of conventional and highly cross-linked ultra-high molecular weight polyethylenes used in total joint replacements Biomaterials 24 2003 3947
    • (2003) Biomaterials , vol.24 , pp. 3947
    • Gencur, S.J.1    Rimnac, C.M.2    Kurtz, S.M.3
  • 4
    • 2442676287 scopus 로고    scopus 로고
    • Wear characteristic and biocompatibility of some polymer composite acetabular cups
    • S.K. Chowdhuvy, A. Mishra, B. Pradhan, and D. Saha Wear characteristic and biocompatibility of some polymer composite acetabular cups Wear 256 2004 1026
    • (2004) Wear , vol.256 , pp. 1026
    • Chowdhuvy, S.K.1    Mishra, A.2    Pradhan, B.3    Saha, D.4
  • 5
    • 0041627754 scopus 로고    scopus 로고
    • Effects of the wollastonite fibre modification on the sliding wear behaviour of the UHMWPE composites
    • J. Tong, Y. Ma, and M. Jiang Effects of the wollastonite fibre modification on the sliding wear behaviour of the UHMWPE composites Wear 225 2003 734
    • (2003) Wear , vol.225 , pp. 734
    • Tong, J.1    Ma, Y.2    Jiang, M.3
  • 6
    • 0032212854 scopus 로고    scopus 로고
    • The yielding, plastic flow, and fracture behaviour of ultra-high molecular weight polyethylene used in total joint replacements
    • M.K. Steven, P. Lisa, W.J. Charles, R.C. Raul, J.C. Deborah, and A.E. Avram The yielding, plastic flow, and fracture behaviour of ultra-high molecular weight polyethylene used in total joint replacements Biomaterials 19 1998 1989
    • (1998) Biomaterials , vol.19 , pp. 1989
    • Steven, M.K.1    Lisa, P.2    Charles, W.J.3    Raul, R.C.4    Deborah, J.C.5    Avram, A.E.6
  • 7
    • 0043023458 scopus 로고    scopus 로고
    • Friction and wear characteristics of various prosthetic materials sliding against smooth diamond-coated titanium alloy
    • C. Met, L. Vandenbulcke, and M.C. Catherine Friction and wear characteristics of various prosthetic materials sliding against smooth diamond-coated titanium alloy Wear 225 2003 1022
    • (2003) Wear , vol.225 , pp. 1022
    • Met, C.1    Vandenbulcke, L.2    Catherine, M.C.3
  • 8
    • 0041562694 scopus 로고    scopus 로고
    • Wear rate and surface morphology of UHMWPE cups affected by the serum lubricant concentration in a hip simulation test
    • Y.S. Liao, D. McNulty, and D. Hanes Wear rate and surface morphology of UHMWPE cups affected by the serum lubricant concentration in a hip simulation test Wear 225 2003 1051
    • (2003) Wear , vol.225 , pp. 1051
    • Liao, Y.S.1    McNulty, D.2    Hanes, D.3
  • 10
    • 0346259931 scopus 로고    scopus 로고
    • Prediction of multi-axial mechanical behaviour for conventional and highly cross-linked UHMWPE using a hybrid constitutive model
    • J.S. Bergstrom, C.M. Rimnac, and S.M. Kurtz Prediction of multi-axial mechanical behaviour for conventional and highly cross-linked UHMWPE using a hybrid constitutive model Biomaterials 24 2003 1365
    • (2003) Biomaterials , vol.24 , pp. 1365
    • Bergstrom, J.S.1    Rimnac, C.M.2    Kurtz, S.M.3
  • 11
    • 0036169065 scopus 로고    scopus 로고
    • An elasto-plastic finite element model for polyethylene wear in total hip arthroplasty
    • S.H. Teoh, W.H. Chan, and R. Thampuran An elasto-plastic finite element model for polyethylene wear in total hip arthroplasty Journal of Biomechanics 35 2003 323
    • (2003) Journal of Biomechanics , vol.35 , pp. 323
    • Teoh, S.H.1    Chan, W.H.2    Thampuran, R.3
  • 12
    • 0036434749 scopus 로고    scopus 로고
    • J-integral fracture toughness and tearing modulus measurement of radiation cross-linked UHMWPE
    • A. Gomoll, T. Wanich, and A. Bellare J-integral fracture toughness and tearing modulus measurement of radiation cross-linked UHMWPE Journal of Orthopaedic Research 20 2003 1152
    • (2003) Journal of Orthopaedic Research , vol.20 , pp. 1152
    • Gomoll, A.1    Wanich, T.2    Bellare, A.3
  • 13
    • 19144369522 scopus 로고    scopus 로고
    • Miniature specimen shear punch test for UHMWPE used in total joint replacements
    • S. Affatato, B. Bordini, C. Fagnano, P. Taddei, A. Tinti, and A. Toni Miniature specimen shear punch test for UHMWPE used in total joint replacements Biomaterials 23 2003 1907
    • (2003) Biomaterials , vol.23 , pp. 1907
    • Affatato, S.1    Bordini, B.2    Fagnano, C.3    Taddei, P.4    Tinti, A.5    Toni, A.6
  • 14
    • 0035482038 scopus 로고    scopus 로고
    • Mechanical behaviour, wear surface morphology, and clinical performance of UHMWPE acetabular components after 10 years of implantation
    • A.A. Edidin, C.M. Rimanac, V.M. Goldberg, and S.M. Kurtz Mechanical behaviour, wear surface morphology, and clinical performance of UHMWPE acetabular components after 10 years of implantation Wear 250 2001 152
    • (2001) Wear , vol.250 , pp. 152
    • Edidin, A.A.1    Rimanac, C.M.2    Goldberg, V.M.3    Kurtz, S.M.4
  • 15
    • 0035425094 scopus 로고    scopus 로고
    • Fracture behaviour of UHMWPE in nano-implanted, self-aged knee prostheses after gamma irradiation in air
    • A.P. Jose, L. Angel, and G.B. Enrique Fracture behaviour of UHMWPE in nano-implanted, self-aged knee prostheses after gamma irradiation in air Biomaterials 22 2001 2107
    • (2001) Biomaterials , vol.22 , pp. 2107
    • Jose, A.P.1    Angel, L.2    Enrique, G.B.3
  • 16
    • 0035307312 scopus 로고    scopus 로고
    • Statistical wear analysis of PA-6/UHMWPE alloy, UHMWPE and PA-6
    • C.Z. Liu, Q. Ren, J. Tong, J. Joyce, S.M. Green, and R.D. Arnell Statistical wear analysis of PA-6/UHMWPE alloy, UHMWPE and PA-6 Wear 249 2003 31
    • (2003) Wear , vol.249 , pp. 31
    • Liu, C.Z.1    Ren, Q.2    Tong, J.3    Joyce, J.4    Green, S.M.5    Arnell, R.D.6
  • 17
    • 0031149270 scopus 로고    scopus 로고
    • Properties of self-reinforced ultra-high molecular-weigh polyethylene composites
    • M. Meng, and W.S. Shalaby Properties of self-reinforced ultra-high molecular-weigh polyethylene composites Biomaterials 18 1997 645
    • (1997) Biomaterials , vol.18 , pp. 645
    • Meng, M.1    Shalaby, W.S.2
  • 18
    • 0038638459 scopus 로고    scopus 로고
    • Effect of sunshine UV irradiation on the tensile properties and structure of ultrahigh molecular weight polyethylene fibers
    • H. Zhang, M. Shi, J. Zhang, and S. Wang Effect of sunshine UV irradiation on the tensile properties and structure of ultrahigh molecular weight polyethylene fibers Journal of Applied Polymer Science 89 2003 2757
    • (2003) Journal of Applied Polymer Science , vol.89 , pp. 2757
    • Zhang, H.1    Shi, M.2    Zhang, J.3    Wang, S.4
  • 21
    • 0032681132 scopus 로고    scopus 로고
    • Surface studies of ultra-high molecular weight polyethylene irradiated with high-energy pulsed electron beams in air
    • N.T. Oleg, F. Shin-Ichi, O. Sakae, and I. Yoshito Surface studies of ultra-high molecular weight polyethylene irradiated with high-energy pulsed electron beams in air Journal of Polymer Science: Part B: Polymer Physics 37 1999 1503
    • (1999) Journal of Polymer Science: Part B: Polymer Physics , vol.37 , pp. 1503
    • Oleg, N.T.1    Shin-Ichi, F.2    Sakae, O.3    Yoshito, I.4
  • 22
    • 0032210244 scopus 로고    scopus 로고
    • Surface cross-linking of polyethylene by electron beam irradiation in air
    • N.T. Oleg, O. Sakae, and I. Yoshito Surface cross-linking of polyethylene by electron beam irradiation in air Polymer 39 1998 615
    • (1998) Polymer , vol.39 , pp. 615
    • Oleg, N.T.1    Sakae, O.2    Yoshito, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.