Volumn 113, Issue 3-4, 2005, Pages 314-320

Bias in the absorption coefficient determination of a fluorescent dye, standard reference material 1932 fluorescein solution

Author keywords

Absorption coefficient; Extinction coefficient; Fluorescein; Fluorescence standard; MESF; SRM 1932

Indexed keywords

BANDPASS FILTERS; CRYSTALLIZATION; DECOMPOSITION; DYES; FLUORESCENCE; MONOCHROMATORS; PH EFFECTS; PURIFICATION; SYSTEMATIC ERRORS; ULTRAVIOLET RADIATION; ULTRAVIOLET SPECTROPHOTOMETERS;

EID: 19044379771     PISSN: 00222313     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jlumin.2004.11.002     Document Type: Article
Times cited : (11)

References (23)
  • 16
    • 19044362427 scopus 로고    scopus 로고
    • Certificate of Analysis, Standard Reference Material 1932, Fluorescein Solution, National Institute of Standards and Technology, March 4
    • Certificate of Analysis, Standard Reference Material 1932, Fluorescein Solution, National Institute of Standards and Technology, March 4, 2003. (http://patapsco.nist.gov/srmcatalog/common/view_detail.cfm?srm=1932).
    • (2003)
  • 18
    • 19044399783 scopus 로고    scopus 로고
    • Certificate of Analysis, Standard Reference Material 930e, Glass Filters for Spectrophotometry, National Institute of Standards and Technology, May 16
    • Certificate of Analysis, Standard Reference Material 930e, Glass Filters for Spectrophotometry, National Institute of Standards and Technology, May 16, 2000. (http://patapsco.nist.gov/srmcatalog/common/view_detail.cfm?srm=930e).
    • (2000)
  • 19
    • 19044377568 scopus 로고    scopus 로고
    • Certificate of Analysis, Standard Reference Material 2034, Holmium Oxide Solution Wavelength Standard from 240 nm to 650 nm, National Institute of Standards and Technology, February 4
    • Certificate of Analysis, Standard Reference Material 2034, Holmium Oxide Solution Wavelength Standard from 240 nm to 650 nm, National Institute of Standards and Technology, February 4, 2002. (http://patapsco.nist.gov/ srmcatalog/common/view_detail.cfm?srm=2034).
    • (2002)
  • 20
    • 19044400410 scopus 로고    scopus 로고
    • note
    • The pathlength measurements of the cuvette were performed between its internal faces, using feeler-gauge type instruments by members of the NIST Precision Engineering Division.
  • 21
    • 19044400622 scopus 로고    scopus 로고
    • note
    • Certain commercial equipment, instruments, or materials are identified in this paper to foster understanding. Such identification does not imply recommendation or endorsement by the National Institute of Standards and Technology, nor does it imply that the materials or equipment identified are necessarily the best available for the purpose.
  • 23
    • 19044376831 scopus 로고    scopus 로고
    • note
    • 0, and Ω is the fraction of fluorescence that reaches the detector.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.