메뉴 건너뛰기




Volumn 34, Issue 3, 2005, Pages 201-208

Decision support for the triage of lung transplant recipients on the basis of home-monitoring spirometry and symptom reporting

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ALGORITHM; ARTICLE; COMPUTER SYSTEM; CONTROLLED STUDY; DATA ANALYSIS; DECISION SUPPORT SYSTEM; EMERGENCY HEALTH SERVICE; FEMALE; FORCED EXPIRATORY VOLUME; HOME MONITORING; HUMAN; LUNG DISEASE; LUNG TRANSPLANTATION; MAJOR CLINICAL STUDY; MALE; MEDICAL RECORD; NURSE; PRIORITY JOURNAL; RECIPIENT; SENSITIVITY AND SPECIFICITY; SPIROMETRY;

EID: 18944400694     PISSN: 01479563     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrtlng.2004.09.003     Document Type: Article
Times cited : (16)

References (25)
  • 1
    • 0037785172 scopus 로고    scopus 로고
    • The registry of the international society of heart and lung transplantation: Twentieth official adult lung and heart-lung transplant report-2003
    • E.P. Trulock, L.B. Edwards, D.O. Taylor, M.M. Boucek, P.J. Mohacsi, B.M. Keck The registry of the international society of heart and lung transplantation twentieth official adult lung and heart-lung transplant report-2003 J Heart Lung Transplant 22 2003 625 635
    • (2003) J Heart Lung Transplant , vol.22 , pp. 625-635
    • Trulock, E.P.1    Edwards, L.B.2    Taylor, D.O.3    Boucek, M.M.4    Mohacsi, P.J.5    Keck, B.M.6
  • 2
    • 18944362006 scopus 로고    scopus 로고
    • Organ Procurement and Transplantation Network website
    • Organ Procurement and Transplantation Network website. Available at: www.optn.org. Accessed May 10, 2004
  • 3
    • 0030912712 scopus 로고    scopus 로고
    • Obliterative bronchiolitis
    • K. Kelly, M.I. Hertz Obliterative bronchiolitis Clin Chest Med 18 1997 319 338
    • (1997) Clin Chest Med , vol.18 , pp. 319-338
    • Kelly, K.1    Hertz, M.I.2
  • 4
    • 0025064237 scopus 로고
    • The use of home spirometry in detecting acute lung rejection and infection following heart-lung transplantation
    • B.A. Otulana, T. Higenbottam, L. Ferrari, J. Scott, G. Igbuoka, J. Wallwork The use of home spirometry in detecting acute lung rejection and infection following heart-lung transplantation Chest 97 1990 353 357
    • (1990) Chest , vol.97 , pp. 353-357
    • Otulana, B.A.1    Higenbottam, T.2    Ferrari, L.3    Scott, J.4    Igbuoka, G.5    Wallwork, J.6
  • 5
    • 0027300606 scopus 로고
    • Daily home spirometry facilitates early detection of rejection in single lung transplant recipients with emphysema
    • O. Bjortuft, B. Johansen, J. Boe, A. Foerster, E. Holter, O. Geiran Daily home spirometry facilitates early detection of rejection in single lung transplant recipients with emphysema Eur Respir J 6 1993 705 708
    • (1993) Eur Respir J , vol.6 , pp. 705-708
    • Bjortuft, O.1    Johansen, B.2    Boe, J.3    Foerster, A.4    Holter, E.5    Geiran, O.6
  • 6
    • 0033388611 scopus 로고    scopus 로고
    • New telemetric system for daily pulmonary function surveillance of lung transplant recipients
    • F.M. Wagner, A. Weber, J.W. Park, S. Schiemanck, S.M. Tugtekin, V. Guliemos New telemetric system for daily pulmonary function surveillance of lung transplant recipients Ann Thorac Surg 68 1999 2033 2038
    • (1999) Ann Thorac Surg , vol.68 , pp. 2033-2038
    • Wagner, F.M.1    Weber, A.2    Park, J.W.3    Schiemanck, S.4    Tugtekin, S.M.5    Guliemos, V.6
  • 7
    • 0036499484 scopus 로고    scopus 로고
    • Internet-based home monitoring of pulmonary function after lung transplantation
    • B. Morlion, C. Knoop, M. Paiva, M. Estenne Internet-based home monitoring of pulmonary function after lung transplantation Am J Respir Crit Care Med 165 2002 694 697
    • (2002) Am J Respir Crit Care Med , vol.165 , pp. 694-697
    • Morlion, B.1    Knoop, C.2    Paiva, M.3    Estenne, M.4
  • 11
    • 0034849750 scopus 로고    scopus 로고
    • Evaluation of a computerized diagnostic decision support system for patients with pneumonia: Study design considerations
    • D. Aronsky, K.J. Chan, P.J. Haug Evaluation of a computerized diagnostic decision support system for patients with pneumonia study design considerations J Am Med Inform Assoc 8 2001 473 485
    • (2001) J Am Med Inform Assoc , vol.8 , pp. 473-485
    • Aronsky, D.1    Chan, K.J.2    Haug, P.J.3
  • 12
    • 0031435211 scopus 로고    scopus 로고
    • Determination of reliability and validity in home monitoring data of pulmonary function tests following lung transplantation
    • B.R. Lindgren, S.M. Finkelstein, B. Prasad, P. Dutta, T. Killoran, J. Scherber Determination of reliability and validity in home monitoring data of pulmonary function tests following lung transplantation Res Nurs Health 20 1997 539 550
    • (1997) Res Nurs Health , vol.20 , pp. 539-550
    • Lindgren, B.R.1    Finkelstein, S.M.2    Prasad, B.3    Dutta, P.4    Killoran, T.5    Scherber, J.6
  • 13
    • 0031772593 scopus 로고    scopus 로고
    • Evaluation of diagnostic tests without gold standards
    • L.S. Hui, X.H. Zhou Evaluation of diagnostic tests without gold standards Stat Methods Med Res 7 1998 354 370
    • (1998) Stat Methods Med Res , vol.7 , pp. 354-370
    • Hui, L.S.1    Zhou, X.H.2
  • 14
    • 0023771727 scopus 로고
    • Estimation of test error rates, disease prevalence and relative risk from misclassified data: A review
    • S.D. Walter, L.M. Irwig Estimation of test error rates, disease prevalence and relative risk from misclassified data a review J Clin Epidemiol 41 1988 923 937
    • (1988) J Clin Epidemiol , vol.41 , pp. 923-937
    • Walter, S.D.1    Irwig, L.M.2
  • 16
    • 18944406455 scopus 로고    scopus 로고
    • GNU website
    • GNU website. Available at: www.gnu.org. Accessed May 14, 2004.
  • 17
    • 18944397437 scopus 로고    scopus 로고
    • PostgreSQL website
    • PostgreSQL website. Available at: www.us.postgres.org. Accessed May 14, 2004.
  • 18
    • 0035811162 scopus 로고    scopus 로고
    • Home monitoring service improves the mean arterial pressure in patients with essential hypertension: A randomized, controlled trial
    • M. Rogers, D. Small, D. Buchan, C.A. Butch, C.M. Stewart, B.E. Krenzer Home monitoring service improves the mean arterial pressure in patients with essential hypertension a randomized, controlled trial Ann Intern Med 134 2001 1024 1032
    • (2001) Ann Intern Med , vol.134 , pp. 1024-1032
    • Rogers, M.1    Small, D.2    Buchan, D.3    Butch, C.A.4    Stewart, C.M.5    Krenzer, B.E.6
  • 19
    • 0036178167 scopus 로고    scopus 로고
    • Columbia University's Informatics for Diabetes Education and Telemedicine (IDEATel) Project: Rationale and design
    • S. Shea, J. Starren, R.S. Weinstock, P.E. Knudson, J. Teresi, D. Holmes Columbia University's Informatics for Diabetes Education and Telemedicine (IDEATel) Project rationale and design J Am Med Inform Assoc 9 2002 49 62
    • (2002) J Am Med Inform Assoc , vol.9 , pp. 49-62
    • Shea, S.1    Starren, J.2    Weinstock, R.S.3    Knudson, P.E.4    Teresi, J.5    Holmes, D.6
  • 20
    • 0036357577 scopus 로고    scopus 로고
    • Teaching self-management of diabetes via telehomecare
    • K.H. Bowles, K.H. Dansky Teaching self-management of diabetes via telehomecare Home Healthc Nurse 20 2002 36 42
    • (2002) Home Healthc Nurse , vol.20 , pp. 36-42
    • Bowles, K.H.1    Dansky, K.H.2
  • 22
    • 0033964437 scopus 로고    scopus 로고
    • Internet-based home asthma telemonitoring: Can patients handle the technology?
    • J. Finkelstein, M.R. Cabrera, G. Hripcsak Internet-based home asthma telemonitoring can patients handle the technology? Chest 117 2000 148 155
    • (2000) Chest , vol.117 , pp. 148-155
    • Finkelstein, J.1    Cabrera, M.R.2    Hripcsak, G.3
  • 23
    • 0035346820 scopus 로고    scopus 로고
    • Facilitators and barriers to adherence wit home monitoring using electronic spirometry
    • N. Sabati, M. Snyder, C. Edin Stibbe, B. Lindgren, S. Finkelstein Facilitators and barriers to adherence wit home monitoring using electronic spirometry AACN Clin Issues 12 2001 178 185
    • (2001) AACN Clin Issues , vol.12 , pp. 178-185
    • Sabati, N.1    Snyder, M.2    Edin Stibbe, C.3    Lindgren, B.4    Finkelstein, S.5
  • 25
    • 0033619696 scopus 로고    scopus 로고
    • Using a combination of reference tests to assess the accuracy of a new diagnostic test
    • T.A. Alonzo, M.S. Pepe Using a combination of reference tests to assess the accuracy of a new diagnostic test Stat Med 18 1999 2987 3003
    • (1999) Stat Med , vol.18 , pp. 2987-3003
    • Alonzo, T.A.1    Pepe, M.S.2