메뉴 건너뛰기




Volumn 11, Issue 2, 2005, Pages 239-262

Ventilation control strategy using the supply CO2 concentration setpoint

Author keywords

[No Author keywords available]

Indexed keywords

AIR QUALITY; CARBON DIOXIDE; CONTROL SYSTEM SYNTHESIS; ENERGY EFFICIENCY; MATHEMATICAL MODELS; ONLINE SYSTEMS; REAL TIME SYSTEMS;

EID: 18944400461     PISSN: 10789669     EISSN: None     Source Type: Journal    
DOI: 10.1080/10789669.2005.10391136     Document Type: Article
Times cited : (35)

References (20)
  • 1
    • 0036459729 scopus 로고    scopus 로고
    • 2-based demand-controlled ventilation strategies
    • 2-based demand-controlled ventilation strategies. ASHRAE Transactions, 108 (2):307–317.
    • (2002) ASHRAE Transactions , vol.108 , Issue.2 , pp. 307-317
    • Alalawi, M.1    Krarti, M.2
  • 4
    • 0030313309 scopus 로고    scopus 로고
    • 2-based demand-controlled ventilation
    • 2-based demand-controlled ventilation. ASHRAE Transactions, 102 (2):80–88.
    • (1996) ASHRAE Transactions , vol.102 , Issue.2 , pp. 80-88
    • Carpenter, S.C.1
  • 5
    • 0042565732 scopus 로고
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., ASHRAE RP-385
    • Degelman, L. O., 1984. Development of Bin Weather Data Atlanta:American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. ASHRAE RP-385
    • (1984) Development of Bin Weather Data
    • Degelman, L.O.1
  • 6
    • 0029487483 scopus 로고
    • Minimum outside air control methods for VAV systems
    • Elovitz, D. M., 1995. Minimum outside air control methods for VAV systems. ASHRAE Transactions, 101 (2):613–618.
    • (1995) ASHRAE Transactions , vol.101 , Issue.2 , pp. 613-618
    • Elovitz, D.M.1
  • 7
    • 0029517671 scopus 로고
    • Strategies for outdoor airflow control from a systems perspective
    • Janu, G. J., Wenger, J. D., and Nesler, C. G., 1995. Strategies for outdoor airflow control from a systems perspective. ASHRAE Transactions, 101 (2):631–643.
    • (1995) ASHRAE Transactions , vol.101 , Issue.2 , pp. 631-643
    • Janu, G.J.1    Wenger, J.D.2    Nesler, C.G.3
  • 8
    • 0033115138 scopus 로고    scopus 로고
    • Variable air ventilation control strategies analysed in six climate zones
    • Ke, Y. P., and Mumma, S. A., 1999. Variable air ventilation control strategies analysed in six climate zones. International Journal of Energy Research, 23:371–387.
    • (1999) International Journal of Energy Research , vol.23 , pp. 371-387
    • Ke, Y.P.1    Mumma, S.A.2
  • 9
    • 0031172389 scopus 로고    scopus 로고
    • Optimized supply-air temperature (SAT) in variable air volume (VAV) systems
    • Ke, Y. P., and Mumma, S. A., 1997a. Optimized supply-air temperature (SAT) in variable air volume (VAV) systems. Energy, 22 (6):601–614.
    • (1997) Energy , vol.22 , Issue.6 , pp. 601-614
    • Ke, Y.P.1    Mumma, S.A.2
  • 10
    • 0031389624 scopus 로고    scopus 로고
    • Using carbon dioxide measurements to determine occupancy for ventilation controls
    • Ke, Y., and Mumma, S., 1997b. Using carbon dioxide measurements to determine occupancy for ventilation controls. ASHRAE Transactions, 103 (2):364–374.
    • (1997) ASHRAE Transactions , vol.103 , Issue.2 , pp. 364-374
    • Ke, Y.1    Mumma, S.2
  • 11
    • 0141725459 scopus 로고    scopus 로고
    • Standard 62's multiple spaces equation: For design, not control
    • Kettler, J., 2003. Standard 62's multiple spaces equation:For design, not control. ASHRAE Journal, 45 (8):20–22.
    • (2003) ASHRAE Journal , vol.45 , Issue.8 , pp. 20-22
    • Kettler, J.1
  • 12
    • 0028698628 scopus 로고
    • Real-time, on-line optimization of VAV system control to minimize the energy consumption rate and to satisfy ASHRAE Standard 62–1989 for all occupied zones
    • Mumma, S. A., and Bolin, R. J., 1994. Real-time, on-line optimization of VAV system control to minimize the energy consumption rate and to satisfy ASHRAE Standard 62–1989 for all occupied zones. ASHRAE Transactions, 100 (1):168–179.
    • (1994) ASHRAE Transactions , vol.100 , Issue.1 , pp. 168-179
    • Mumma, S.A.1    Bolin, R.J.2
  • 16
    • 0005202259 scopus 로고
    • Ventilation, carbon dioxide and ASHRAE Standard 62–1989
    • Persily, A. K., 1993. Ventilation, carbon dioxide and ASHRAE Standard 62–1989. ASHRAE Journal, 35 (7):40–44.
    • (1993) ASHRAE Journal , vol.35 , Issue.7 , pp. 40-44
    • Persily, A.K.1
  • 17
    • 0032301954 scopus 로고    scopus 로고
    • A study of energy use and satisfactory zone ventilation of different outdoor air ventilation strategies for terminal reheat variable air volume systems
    • Reddy, T. A., Liu, M., and Claridge, D. E., 1998. A study of energy use and satisfactory zone ventilation of different outdoor air ventilation strategies for terminal reheat variable air volume systems. Energy and Buildings, 29:65–75.
    • (1998) Energy and Buildings , vol.29 , pp. 65-75
    • Reddy, T.A.1    Liu, M.2    Claridge, D.E.3
  • 19
    • 0036884477 scopus 로고    scopus 로고
    • A robust control strategy for combining DCV control with economizer control
    • Wang, S., and Xu, X., 2002. A robust control strategy for combining DCV control with economizer control. Energy Conversion and Management, 43:2569–2588.
    • (2002) Energy Conversion and Management , vol.43 , pp. 2569-2588
    • Wang, S.1    Xu, X.2
  • 20
    • 0000610429 scopus 로고    scopus 로고
    • 2-based occupancy detection for on-line outdoor air flow control
    • 2-based occupancy detection for on-line outdoor air flow control. Indoor Built Environment, 7:165–181.
    • (1998) Indoor Built Environment , vol.7 , pp. 165-181
    • Wang, S.1    Jin, X.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.