Volumn 130, Issue 18, 2005, Pages 1129-1132

Complications of central venous access devices: Outcome analysis of 2359 implantations;Komplikationen zentralvenöser portsysteme: Erfahrungsbericht über 2359 implantationen

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CANCER PATIENT; CENTRAL VENOUS CATHETER; FEMALE; HUMAN; IMPLANTATION; LOCAL ANESTHESIA; MAJOR CLINICAL STUDY; MALE; PNEUMOTHORAX; POSTOPERATIVE COMPLICATION; POSTOPERATIVE HEMORRHAGE; POSTOPERATIVE INFECTION; POSTOPERATIVE THROMBOSIS; REOPERATION; SUBCLAVIAN VEIN; VASCULAR ACCESS; CATHETERIZATION; INDWELLING CATHETER; INFECTION; METHODOLOGY; MIDDLE AGED; OUTCOME ASSESSMENT; THROMBOSIS; TREATMENT OUTCOME;

EID: 18944400000     PISSN: 00120472     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2005-866798     Document Type: Article
Times cited : (18)

References (12)
  • 1
    • 0021705456 scopus 로고
    • The "pinch-off-sign": A warning of impending problems with permanent subclavian catheters
    • Aitken DR, Minton JP. The "pinch-off-sign": A warning of impending problems with permanent subclavian catheters. Ann J Surg 1984; 148: 633-636
    • (1984) Ann J Surg , vol.148 , pp. 633-636
    • Aitken, D.R.1    Minton, J.P.2
  • 2
    • 0033945702 scopus 로고    scopus 로고
    • Peripheral venous access ports: Outcomes analysis in 109 patients
    • Bodner LJ, Nosher JL, Patel KM et al. Peripheral venous access ports: outcomes analysis in 109 patients. Cardiovasc Intervent Radiol 2000; 23: 187-193
    • (2000) Cardiovasc Intervent Radiol , vol.23 , pp. 187-193
    • Bodner, L.J.1    Nosher, J.L.2    Patel, K.M.3
  • 4
    • 0025043250 scopus 로고
    • Pinch-off syndrome: A complication of implantable subclavian venous access devices
    • Hinke DH, Zandt-Stastny DA, Goodman LR et al. Pinch-off syndrome: A complication of implantable subclavian venous access devices. Radiology 1990; 177: 353-356
    • (1990) Radiology , vol.177 , pp. 353-356
    • Hinke, D.H.1    Zandt-Stastny, D.A.2    Goodman, L.R.3
  • 5
    • 0035037048 scopus 로고    scopus 로고
    • Pinch-off-zeichen: Management einer ungewöhnlichen portkomplikation
    • Jordan K, Behrmann C, Rie C, Bläser F, Dempke W. Pinch-off-Zeichen: Management einer ungewöhnlichen Portkomplikation. Onkologe 2001; 7: 438-442
    • (2001) Onkologe , vol.7 , pp. 438-442
    • Jordan, K.1    Behrmann, C.2    Rie, C.3    Bläser, F.4    Dempke, W.5
  • 6
    • 0029949637 scopus 로고    scopus 로고
    • Catheter fracture: A rare complication of totally implantable subclavian venous access devices
    • Klotz HP, Schöpke W, Kohler A, Pestalozzi B, Largiader F. Catheter Fracture: A Rare Complication of Totally Implantable Subclavian Venous Access Devices. J Surg Oncol 1996; 62: 222-225
    • (1996) J Surg Oncol , vol.62 , pp. 222-225
    • Klotz, H.P.1    Schöpke, W.2    Kohler, A.3    Pestalozzi, B.4    Largiader, F.5
  • 7
    • 0031964073 scopus 로고    scopus 로고
    • Implantable vascular access systems: Expirience in 1500 patients with totally implanted central venous port systems
    • Kock HJ, Pietsch M, Krause U, Wilke H, Eigler FW. Implantable vascular access systems: expirience in 1500 patients with totally implanted central venous port systems. World J Surg 1998; 22: 12-16
    • (1998) World J Surg , vol.22 , pp. 12-16
    • Kock, H.J.1    Pietsch, M.2    Krause, U.3    Wilke, H.4    Eigler, F.W.5
  • 8
    • 0027357275 scopus 로고
    • Venous access devices: A review
    • Ledgerwood AM, Saxe JM, Lucas CE. Venous access devices: A review. Surg Annu 1993; 25 (Pt 2); 45-57
    • (1993) Surg Annu , vol.25 , Issue.PART 2 , pp. 45-57
    • Ledgerwood, A.M.1    Saxe, J.M.2    Lucas, C.E.3
  • 9
    • 0036652923 scopus 로고    scopus 로고
    • Portkatheterbrüche bei 361 implantierten portsystemen: Ursachenanlyse-lösungsmöglichkeiten-literaturübersicht
    • Leinung S, Würl P, Anders K, Deckert F, Schönefelder M. Portkatheterbrüche bei 361 implantierten Portsystemen: Ursachenanlyse- Lösungsmöglichkeiten-Literaturübersicht. Chirurg 2002; 73: 696-699
    • (2002) Chirurg , vol.73 , pp. 696-699
    • Leinung, S.1    Würl, P.2    Anders, K.3    Deckert, F.4    Schönefelder, M.5
  • 10
    • 0025974464 scopus 로고
    • Continuous infusion of chemotherapy on an outpatient basis via totally implanted venous access port
    • Nanninga AG, de Vries EGE, Willemse PH et al. Continuous infusion of chemotherapy on an outpatient basis via totally implanted venous access port. Eur J Cancer 1991; 27: 149-154
    • (1991) Eur J Cancer , vol.27 , pp. 149-154
    • Nanninga, A.G.1    De Vries, E.G.E.2    Willemse, P.H.3
  • 11
    • 0031837638 scopus 로고    scopus 로고
    • Complications in connection with venous port systems: Prevention and therapy
    • Rauthe G, Altmann C. Complications in connection with venous port systems: prevention and therapy. EUR J Surg Oncol 1998; 24: 192-199
    • (1998) EUR J Surg Oncol , vol.24 , pp. 192-199
    • Rauthe, G.1    Altmann, C.2
  • 12
    • 0032981874 scopus 로고    scopus 로고
    • Incidence and management of catheter occlusion in implantable arm ports: Results in 391 patients
    • Whigham CJ, Greenbaum MC, Fisher RG, Goodmann CJ, Thornby JI, Thomas JW. Incidence and Management of Catheter Occlusion in Implantable Arm Ports: Results in 391 Patients. JVIR 1999; 10: 767-774
    • (1999) JVIR , vol.10 , pp. 767-774
    • Whigham, C.J.1    Greenbaum, M.C.2    Fisher, R.G.3    Goodmann, C.J.4    Thornby, J.I.5    Thomas, J.W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.