-
1
-
-
0041872022
-
Hot-wire anemometry
-
edited by R. W. Johnson, CRC Press, Boca Raton, FL, Chap. 34
-
Comte-Bellot, G., "Hot-Wire Anemometry," Handbook of Fluid Dynamics, edited by R. W. Johnson, CRC Press, Boca Raton, FL, 1998, Chap. 34.
-
(1998)
Handbook of Fluid Dynamics
-
-
Comte-Bellot, G.1
-
2
-
-
0018982322
-
Determination and optimization of frequency response of constant temperature hot-wire anemometers in supersonic flows
-
Bonnet, J. P., and Alziary de Roquefort, T., "Determination and Optimization of Frequency Response of Constant Temperature Hot-Wire Anemometers in Supersonic Flows," Review of Scientific Instruments, Vol. 51, No. 2, 1980, pp. 234-239.
-
(1980)
Review of Scientific Instruments
, vol.51
, Issue.2
, pp. 234-239
-
-
Bonnet, J.P.1
Alziary De Roquefort, T.2
-
3
-
-
0010117665
-
Constant-temperature anemometry in hypersonic flow: Critical issues and sample results
-
Spina, E. F., and McGinley, C. B., "Constant-Temperature Anemometry in Hypersonic Flow: Critical Issues and Sample Results," Experiments in Fluids, Vol. 17, No. 6, 1994, pp. 365-374.
-
(1994)
Experiments in Fluids
, vol.17
, Issue.6
, pp. 365-374
-
-
Spina, E.F.1
McGinley, C.B.2
-
4
-
-
0031694257
-
Transfer function analysis of the constant voltage anemometer
-
Sarma, G. R., "Transfer Function Analysis of the Constant Voltage Anemometer," Review of Scientific Instruments, Vol. 69, No. 6, 1998, pp. 2385-2391.
-
(1998)
Review of Scientific Instruments
, vol.69
, Issue.6
, pp. 2385-2391
-
-
Sarma, G.R.1
-
5
-
-
0030405648
-
Boundary-layer stability measurements in a hypersonic quiet tunnel
-
Lachowicz, J. T., Chokani, N., and Wilkinson, S. P., "Boundary-Layer Stability Measurements in a Hypersonic Quiet Tunnel," AIAA Journal, Vol. 34, No. 12, 1996, pp. 2496-2500.
-
(1996)
AIAA Journal
, vol.34
, Issue.12
, pp. 2496-2500
-
-
Lachowicz, J.T.1
Chokani, N.2
Wilkinson, S.P.3
-
6
-
-
0032406408
-
Software corrected hot wire thermal lag for the constant voltage anemometer featuring a constant bandwidth at the selected compensation setting
-
Sarma, G. R., Comte-Bellot, G., and Faure, T. M., "Software Corrected Hot Wire Thermal Lag for the Constant Voltage Anemometer Featuring a Constant Bandwidth at the Selected Compensation Setting," Review of Scientific Instruments, Vol. 69, No. 9, 1998, pp. 3223-3231.
-
(1998)
Review of Scientific Instruments
, vol.69
, Issue.9
, pp. 3223-3231
-
-
Sarma, G.R.1
Comte-Bellot, G.2
Faure, T.M.3
-
7
-
-
0010021877
-
A comparative study of constant-voltage and constant-temperature hot-wire anemometers: Part II - The dynamic response
-
Kegerise, M. A., and Spina, E. F., "A Comparative Study of Constant-Voltage and Constant-Temperature Hot-Wire Anemometers: Part II - The Dynamic Response," Experiments in Fluids, Vol. 29, No. 2, 2000, pp. 165-177.
-
(2000)
Experiments in Fluids
, vol.29
, Issue.2
, pp. 165-177
-
-
Kegerise, M.A.1
Spina, E.F.2
-
8
-
-
0034832331
-
Constant voltage anemometer practice in supersonic flows
-
Comte-Bellot, G., and Sarma, G. R., "Constant Voltage Anemometer Practice in Supersonic Flows," AIAA Journal, Vol. 39, No. 2, 2001, pp. 261-270.
-
(2001)
AIAA Journal
, vol.39
, Issue.2
, pp. 261-270
-
-
Comte-Bellot, G.1
Sarma, G.R.2
-
9
-
-
0041423904
-
Experimental determination of the free-stream disturbance field in a short duration supersonic wind tunnel
-
Weiss, J., Knauss, H., and Wagner, S., "Experimental Determination of the Free-Stream Disturbance Field in a Short Duration Supersonic Wind Tunnel," Experiments in Fluids, Vol. 35, No. 4, 2003, pp. 291-302.
-
(2003)
Experiments in Fluids
, vol.35
, Issue.4
, pp. 291-302
-
-
Weiss, J.1
Knauss, H.2
Wagner, S.3
-
10
-
-
0040158751
-
Method for the determination of frequency response and signal to noise ratio for constant-temperature hot-wire anemometers
-
Weiss, J., Knauss, H., and Wagner, S., "Method for the Determination of Frequency Response and Signal to Noise Ratio for Constant-Temperature Hot-Wire Anemometers," Review of Scientific Instruments, Vol. 72, No. 3, 2001, pp. 1904-1909.
-
(2001)
Review of Scientific Instruments
, vol.72
, Issue.3
, pp. 1904-1909
-
-
Weiss, J.1
Knauss, H.2
Wagner, S.3
-
11
-
-
0042886061
-
Rapid scanning of overheat ratios using a constant voltage anemometer
-
Norris, J. D., and Chokani, N., "Rapid Scanning of Overheat Ratios Using a Constant Voltage Anemometer," AIAA Journal, Vol. 41, No. 8, 2003, pp. 1619, 1620.
-
(2003)
AIAA Journal
, vol.41
, Issue.8
, pp. 1619
-
-
Norris, J.D.1
Chokani, N.2
-
12
-
-
0013385045
-
Noise in hot-wire anemometers
-
Freymuth, P., "Noise in Hot-Wire Anemometers," Review of Scientific Instruments, Vol. 39, No. 4, 1968, pp. 550-557.
-
(1968)
Review of Scientific Instruments
, vol.39
, Issue.4
, pp. 550-557
-
-
Freymuth, P.1
-
13
-
-
0030258584
-
Hot-wire anemometry behavior at very high frequencies
-
Saddoughi, S. G., and Veeravali, S. V., "Hot-Wire Anemometry Behavior at Very High Frequencies," Measurement Science and Technology, Vol. 7, No. 10, 1996, pp. 1297-1300.
-
(1996)
Measurement Science and Technology
, vol.7
, Issue.10
, pp. 1297-1300
-
-
Saddoughi, S.G.1
Veeravali, S.V.2
-
14
-
-
3042642277
-
Electronic noise in a constant voltage anemometer
-
Weiss, J., and Comte-Bellot, G., "Electronic Noise in a Constant Voltage Anemometer," Review of Scientific Instruments, Vol. 75, No. 5, 2004, pp. 1290-1296.
-
(2004)
Review of Scientific Instruments
, vol.75
, Issue.5
, pp. 1290-1296
-
-
Weiss, J.1
Comte-Bellot, G.2
|