메뉴 건너뛰기




Volumn 13, Issue 1, 2005, Pages 1-3

Magnetic susceptibility artifact in orbital magnetic resonance imaging

Author keywords

Artifacts; Botulinum toxin; Esotropia; Lateral rectus; Magnetic resonance imaging; Strabismus surgery

Indexed keywords

BOTULINUM TOXIN; BOTULINUM TOXIN A;

EID: 18944364616     PISSN: 09273972     EISSN: 17445132     Source Type: Journal    
DOI: 10.1080/09273970490887485     Document Type: Article
Times cited : (1)

References (7)
  • 1
    • 0027425147 scopus 로고
    • Cine magnetic resonance imaging of eye movements
    • Bailey CC, Kabala J, Laitt R, et al. Cine magnetic resonance imaging of eye movements. Eye. 1993;7(5):691-693.
    • (1993) Eye , vol.7 , Issue.5 , pp. 691-693
    • Bailey, C.C.1    Kabala, J.2    Laitt, R.3
  • 2
    • 0032082698 scopus 로고    scopus 로고
    • Video-loop MRI of ocular motility: A new technique: Turbo rare sequence at 2 T for the study of horizontal gaze
    • Speeg-Schatz C, Scheiber C, Passard C, et al. Video-loop MRI of ocular motility: a new technique: turbo rare sequence at 2 T for the study of horizontal gaze. Binocul. Vis. Strabismus Q. 1998;13(2 2nd Qtr):105-114.
    • (1998) Binocul Vis Strabismus Q , vol.13 , Issue.2 2ND QTR. , pp. 105-114
    • Speeg-Schatz, C.1    Scheiber, C.2    Passard, C.3
  • 3
    • 0032839650 scopus 로고    scopus 로고
    • Lenticular opacities in individuals exposed to ionizing radiation in infancy
    • Hall P, Granath F, Lundell M, et al. Lenticular opacities in individuals exposed to ionizing radiation in infancy. Pediatr Res. 1999;152:190-195.
    • (1999) Pediatr Res , vol.152 , pp. 190-195
    • Hall, P.1    Granath, F.2    Lundell, M.3
  • 4
    • 0031137590 scopus 로고    scopus 로고
    • Artifacts and pitfalls in MR imaging of the orbit: A clinical review
    • Herrick RC, Hayman LA, Taber KH, et al. Artifacts and pitfalls in MR imaging of the orbit: a clinical review. RadioGraphics. 1997;17(3):707-724.
    • (1997) RadioGraphics , vol.17 , Issue.3 , pp. 707-724
    • Herrick, R.C.1    Hayman, L.A.2    Taber, K.H.3
  • 5
    • 0033963132 scopus 로고    scopus 로고
    • Anatomy of the orbital apex and cavernous sinus on high-resolution magnetic resonance images
    • Ettl A, Zwrtek K, Daxer A, Salomonowitz E. Anatomy of the orbital apex and cavernous sinus on high-resolution magnetic resonance images. Surv Ophthalmol. 2000;44(4):303-323.
    • (2000) Surv Ophthalmol , vol.44 , Issue.4 , pp. 303-323
    • Ettl, A.1    Zwrtek, K.2    Daxer, A.3    Salomonowitz, E.4
  • 6
    • 0020614309 scopus 로고
    • Potential hazards and artifacts of ferromagnetic and non-ferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging
    • New PF, Rosen BR, Brady TJ, et al. Potential hazards and artifacts of ferromagnetic and non-ferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology. 1983;147:139-148.
    • (1983) Radiology , vol.147 , pp. 139-148
    • New, P.F.1    Rosen, B.R.2    Brady, T.J.3
  • 7
    • 0027379107 scopus 로고
    • MR procedures and biomedical implants, materials, and devices: 1993 Update
    • Shellock FG, Morisoli S, Kanal E. MR procedures and biomedical implants, materials, and devices: 1993 update. Radiology. 1993;189:587-599.
    • (1993) Radiology , vol.189 , pp. 587-599
    • Shellock, F.G.1    Morisoli, S.2    Kanal, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.