-
1
-
-
0021957218
-
Potable water as a source of Legionnaires' disease
-
Shands K, Ho J, Meyer R, et al. Potable water as a source of Legionnaires' disease. JAMA 1985;253:1412-1416.
-
(1985)
JAMA
, vol.253
, pp. 1412-1416
-
-
Shands, K.1
Ho, J.2
Meyer, R.3
-
2
-
-
0032239941
-
More than ten years of unrecognized nosocomial transmission of Legionnaires' disease among transplant patients
-
Kool JL, Fiore AE, Kioski CM, et al. More than ten years of unrecognized nosocomial transmission of Legionnaires' disease among transplant patients. Infect Control Hosp Epidemiol 1998;19:898-904.
-
(1998)
Infect Control Hosp Epidemiol
, vol.19
, pp. 898-904
-
-
Kool, J.L.1
Fiore, A.E.2
Kioski, C.M.3
-
3
-
-
0033845771
-
Nosocomial legionellosis
-
Yu VL. Nosocomial legionellosis. Curr Opin Infect Dis 2000;13:385-388.
-
(2000)
Curr Opin Infect Dis
, vol.13
, pp. 385-388
-
-
Yu, V.L.1
-
4
-
-
0042431709
-
Progress in the battle against nosocomial Legionnaires' disease: Shedding light on shades of gray
-
Craven DE. Progress in the battle against nosocomial Legionnaires' disease: shedding light on shades of gray. Infect Control Hosp Epidemiol 2003;24:560-562.
-
(2003)
Infect Control Hosp Epidemiol
, vol.24
, pp. 560-562
-
-
Craven, D.E.1
-
5
-
-
0035708702
-
Legionella in the hospital water supply: A plea for decision making based on evidence-based medicine
-
Stout JE, Yu VL. Legionella in the hospital water supply: a plea for decision making based on evidence-based medicine. Infect Control Hosp Epidemiol 2001;22:670-672.
-
(2001)
Infect Control Hosp Epidemiol
, vol.22
, pp. 670-672
-
-
Stout, J.E.1
Yu, V.L.2
-
6
-
-
0031862243
-
Disinfection of water distribution systems for Legionella
-
Lin YS, Stout JE, Yu VL, et al. Disinfection of water distribution systems for Legionella. Semin Respir Infect 1998;13:147-159.
-
(1998)
Semin Respir Infect
, vol.13
, pp. 147-159
-
-
Lin, Y.S.1
Stout, J.E.2
Yu, V.L.3
-
7
-
-
0029380391
-
Efficacy of ultraviolet light in preventing Legionella colonization of a hospital water distribution system
-
Liu Z, Stout JE, Tedesco L, et al. Efficacy of ultraviolet light in preventing Legionella colonization of a hospital water distribution system. Water Res 1995;29:2275-2280.
-
(1995)
Water Res
, vol.29
, pp. 2275-2280
-
-
Liu, Z.1
Stout, J.E.2
Tedesco, L.3
-
8
-
-
0021355053
-
Heat eradication measures for control of hospital-acquired Legionnaires' disease: Implementation, education, and cost analysis
-
Best MG, Goetz A, Yu VL. Heat eradication measures for control of hospital-acquired Legionnaires' disease: implementation, education, and cost analysis. Am J Infect Control 1984;12:26-30.
-
(1984)
Am J Infect Control
, vol.12
, pp. 26-30
-
-
Best, M.G.1
Goetz, A.2
Yu, V.L.3
-
9
-
-
0025364666
-
Reduction in Legionella pneumophila through heat flushing followed by continuous supplemental chlorination of hospital hot water
-
Snyder MB, Siwicki M, Wireman J, et al. Reduction in Legionella pneumophila through heat flushing followed by continuous supplemental chlorination of hospital hot water. J Infect Dis 1990;162:127-132.
-
(1990)
J Infect Dis
, vol.162
, pp. 127-132
-
-
Snyder, M.B.1
Siwicki, M.2
Wireman, J.3
-
10
-
-
0030880260
-
Colonization of transplant unit water supplies with Legionella and protozoa: Precautions required to reduce the risk of legionellosis
-
Patterson WJ, Hay J, Seal DV, et al. Colonization of transplant unit water supplies with Legionella and protozoa: precautions required to reduce the risk of legionellosis. J Hosp Infect 1997;37:7-17.
-
(1997)
J Hosp Infect
, vol.37
, pp. 7-17
-
-
Patterson, W.J.1
Hay, J.2
Seal, D.V.3
-
11
-
-
18844392664
-
Circulaire DGS/SD7A/SD5C-DHOS/E4 n°2002/243 du 24 avril 2002 relative à la prevention du risque lié aux legionelles dans les établissements de santé
-
Direction Générale De La Santé. Circulaire DGS/SD7A/SD5C-DHOS/E4 n°2002/243 du 24 avril 2002 relative à la prevention du risque lié aux legionelles dans les établissements de santé. Bulletin Officiel 2002;18.
-
(2002)
Bulletin Officiel
, pp. 18
-
-
-
14
-
-
0031550146
-
Guidelines for prevention of nosocomial pneumonia
-
Centers for Disease Control and Prevention. Guidelines for prevention of nosocomial pneumonia. MMWR 1997;46(RR-1):1-79.
-
(1997)
MMWR
, vol.46
, Issue.RR-1
, pp. 1-179
-
-
-
15
-
-
84921537511
-
Guidelines for preventing opportunistic infections (OIs) in hematopoietic stem cell transplant recipients (HSCT)
-
Centers for Disease Control and Prevention, Infectious Diseases Society of America, and American Society of Blood and Marrow Transplantation. Guidelines for preventing opportunistic infections (OIs) in hematopoietic stem cell transplant recipients (HSCT). MMWR 2000;49(RR-1):1-128.
-
(2000)
MMWR
, vol.49
, Issue.RR-1
, pp. 1-128
-
-
-
17
-
-
0003615047
-
-
Atlanta, GA: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.
-
American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. ASHRAE Guideline: Minimizing the Risk of Legionellosis Associated With Building Water System. Atlanta, GA: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.; 2000.
-
(2000)
ASHRAE Guideline: Minimizing the Risk of Legionellosis Associated with Building Water System
-
-
-
18
-
-
9244226713
-
Guidelines for prevention of health care-associated pneumonia
-
Centers for Disease Control and Prevention. Guidelines for prevention of health care-associated pneumonia. MMWR 2004;53(RR-3):1-36.
-
(2004)
MMWR
, vol.53
, Issue.RR-3
, pp. 1-336
-
-
-
19
-
-
0042831011
-
Experiences of the first 16 hospitals using copper-silver ionization for Legionella control: Implications for the evaluation of other disinfection modalities
-
Stout JE, Yu VL. Experiences of the first 16 hospitals using copper-silver ionization for Legionella control: implications for the evaluation of other disinfection modalities. Infect Control Hosp Epidemiol 2003;24:563-568.
-
(2003)
Infect Control Hosp Epidemiol
, vol.24
, pp. 563-568
-
-
Stout, J.E.1
Yu, V.L.2
-
20
-
-
0042831009
-
A 17-month evaluation of a chlorine dioxide water treatment system to control Legionella species in a hospital water supply
-
Srinivasan A, Bova G, Ross T, et al. A 17-month evaluation of a chlorine dioxide water treatment system to control Legionella species in a hospital water supply. Infect Control Hosp Epidemiol 2003;24:575-579.
-
(2003)
Infect Control Hosp Epidemiol
, vol.24
, pp. 575-579
-
-
Srinivasan, A.1
Bova, G.2
Ross, T.3
-
21
-
-
0041328412
-
Risk of hospital-acquired Legionnaires' disease in cities using monochloramine versus other water disinfectants
-
Heffelfinger JD, Kool JL, Fridkin S, et al. Risk of hospital-acquired Legionnaires' disease in cities using monochloramine versus other water disinfectants. Infect Control Hosp Epidemiol 2003;24:569-574.
-
(2003)
Infect Control Hosp Epidemiol
, vol.24
, pp. 569-574
-
-
Heffelfinger, J.D.1
Kool, J.L.2
Fridkin, S.3
-
22
-
-
0042831008
-
Ultraviolet light disinfection of hospital water for preventing nosocomial Legionella infection: A 13-year follow-up
-
Hall KK, Giannetta ET, Getchell-White SI, et al. Ultraviolet light disinfection of hospital water for preventing nosocomial Legionella infection: a 13-year follow-up. Infect Control Hosp Epidemiol 2003;24:580-583.
-
(2003)
Infect Control Hosp Epidemiol
, vol.24
, pp. 580-583
-
-
Hall, K.K.1
Giannetta, E.T.2
Getchell-White, S.I.3
-
23
-
-
0036431348
-
Peracetic acid as an alternative wastewater disinfectant to chlorine dioxide
-
Stampi S, De Luca G, Onorato M, et al. Peracetic acid as an alternative wastewater disinfectant to chlorine dioxide. J Appl Microbiol 2002;93:725-731.
-
(2002)
J Appl Microbiol
, vol.93
, pp. 725-731
-
-
Stampi, S.1
De Luca, G.2
Onorato, M.3
-
24
-
-
18844419845
-
Disinfection efficiency of peracetic acid, UV and ozone after enhanced treatment of municipal wastewater
-
Gehr R, Wagner M, Veerasubramanian P, et al. Disinfection efficiency of peracetic acid, UV and ozone after enhanced treatment of municipal wastewater. Water Res 2003;37:78-94.
-
(2003)
Water Res
, vol.37
, pp. 78-94
-
-
Gehr, R.1
Wagner, M.2
Veerasubramanian, P.3
-
25
-
-
0037210122
-
Pilot-plant comparative study of peracetic acid and sodium hypochlorite wastewater disinfection
-
Veschetti E, Cutilli D, Bonadonna L, et al. Pilot-plant comparative study of peracetic acid and sodium hypochlorite wastewater disinfection. Water Res 2003;37:4573-4586.
-
(2003)
Water Res
, vol.37
, pp. 4573-4586
-
-
Veschetti, E.1
Cutilli, D.2
Bonadonna, L.3
-
27
-
-
0003646431
-
-
Geneva: International Standard Organization, 11731-1998
-
International Standard Organization. Water Quality: Detection and Enumeration of Legionella. Geneva: International Standard Organization; 1998, 11731-1998.
-
(1998)
Water Quality: Detection and Enumeration of Legionella
-
-
-
28
-
-
18844428697
-
Valutazione dell'efficacia di interventi di disinfezione di impianti idrici ospedalieri contaminati da Legionella
-
Guidetti L, Ditommaso S, Giacomuzzi M, et al. Valutazione dell'efficacia di interventi di disinfezione di impianti idrici ospedalieri contaminati da Legionella. Giornale Italiano delle Infezioni ospedaliere 2000;7:97-103.
-
(2000)
Giornale Italiano delle Infezioni Ospedaliere
, vol.7
, pp. 97-103
-
-
Guidetti, L.1
Ditommaso, S.2
Giacomuzzi, M.3
-
29
-
-
33746640103
-
Studies on mutagenicity and disinfection by-products in river drinking water disinfected with peracetic acid or sodium hypochlorite
-
October 15-19; Berlin, Germany
-
Monarca S, Ferretti D, Zerbini I, et al. Studies on mutagenicity and disinfection by-products in river drinking water disinfected with peracetic acid or sodium hypochlorite. Presented at the International Water Association World Conference; October 15-19, 2001; Berlin, Germany.
-
(2001)
International Water Association World Conference
-
-
Monarca, S.1
Ferretti, D.2
Zerbini, I.3
-
30
-
-
0036144301
-
Mutagenicity and disinfection by-products in surface drinking water disinfected with peracetic acid
-
Monarca S, Richardson SD, Ferretti D, et al. Mutagenicity and disinfection by-products in surface drinking water disinfected with peracetic acid. Environ Toxicol Chem 2002;21:309-318.
-
(2002)
Environ Toxicol Chem
, vol.21
, pp. 309-318
-
-
Monarca, S.1
Richardson, S.D.2
Ferretti, D.3
-
31
-
-
0002215836
-
Disinfection with peroxygens
-
Payne KR, ed. New York: Wiley
-
Baldry MGC, Fraser JAL. Disinfection with peroxygens. In: Payne KR, ed. Industrial Biocides. New York: Wiley; 1988:91-116.
-
(1988)
Industrial Biocides
, pp. 91-116
-
-
Baldry, M.G.C.1
Fraser, J.A.L.2
-
32
-
-
0021804288
-
Use of peracetic acid in operational sewage sludge disposal to pasture
-
Fraser JAL, Godfree AF, Jones F. Use of peracetic acid in operational sewage sludge disposal to pasture. Water Sci Technol 1984;17:451-466.
-
(1984)
Water Sci Technol
, vol.17
, pp. 451-466
-
-
Fraser, J.A.L.1
Godfree, A.F.2
Jones, F.3
-
33
-
-
0001013296
-
Peracetic acid: Disinfectant for the food industry
-
Schroder W. Peracetic acid: disinfectant for the food industry. Brauwelt Int 1984:115-120.
-
(1984)
Brauwelt Int
, pp. 115-120
-
-
Schroder, W.1
|