Very small air bubbles (10-70 μl) cause clinically significant variability in syringe pump fluid delivery

Author keywords

Administration and dosage (AD); Adverse effects (AE); Air; Infusion pumps; Infusions; Intravenous

Indexed keywords

ALARM SYSTEMS; BUBBLES (IN FLUIDS); FLOW OF FLUIDS; GRAVIMETRIC ANALYSIS; PATIENT TREATMENT; RISK MANAGEMENT; SYRINGES; TRANSIENTS;

EID: 18844414505     PISSN: 03091902     EISSN: None     Source Type: Journal    
DOI: 10.1080/03091900500067801     Document Type: Article
Times cited : (10)

References (25)
  • 2
    • 0027168847 scopus 로고
    • Influence of infusion-pump operation and flow-rate on hemodynamic stability during epinephrine infusion
    • Klem, S.A., Farrington, J.M. and Leff, R.D., 1993, Influence of infusion-pump operation and flow-rate on hemodynamic stability during epinephrine infusion. Critical Care Medicine, 21, 1213-1217.
    • (1993) Critical Care Medicine , vol.21 , pp. 1213-1217
    • Klem, S.A.1    Farrington, J.M.2    Leff, R.D.3
  • 4
    • 0023787920 scopus 로고
    • Flow-rate variability from electronic infusion devices
    • Stull, J.C., Erenberg, A. and Leff, R.D., 1988, Flow-rate variability from electronic infusion devices. Critical Care Medicine, 16, 888-891.
    • (1988) Critical Care Medicine , vol.16 , pp. 888-891
    • Stull, J.C.1    Erenberg, A.2    Leff, R.D.3
  • 6
    • 0027215610 scopus 로고
    • Dopamine infused continuously at high-concentration with a low-flow rate affects arterial blood-pressure fluctuation waves
    • Shibata, H., Aibiki, M., Shirakawa, Y. and Ogli, K., 1993, Dopamine infused continuously at high-concentration with a low-flow rate affects arterial blood-pressure fluctuation waves. Critical Care Medicine, 21, 801-804.
    • (1993) Critical Care Medicine , vol.21 , pp. 801-804
    • Shibata, H.1    Aibiki, M.2    Shirakawa, Y.3    Ogli, K.4
  • 8
    • 0023449061 scopus 로고
    • Features of IV devices and equipment that affect IV DRUG delivery
    • Leff, R.D., 1987, Features of IV devices and equipment that affect IV DRUG delivery. American Journal of Hospital Pharmacy, 44, 2530-2533.
    • (1987) American Journal of Hospital Pharmacy , vol.44 , pp. 2530-2533
    • Leff, R.D.1
  • 9
    • 0030695421 scopus 로고    scopus 로고
    • Design Flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors
    • Lonnqvist, P.A. and Lonnqvist, P.A., 1997, Design Flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors. Intensive Care Medicine, 23, 998-1001.
    • (1997) Intensive Care Medicine , vol.23 , pp. 998-1001
    • Lonnqvist, P.A.1    Lonnqvist, P.A.2
  • 10
    • 0033945017 scopus 로고    scopus 로고
    • How continuous are continuous drug infusions?
    • Lonnqvist, P.A., 2000, How continuous are continuous drug infusions? Intensive Care Medicine, 26, 660-661.
    • (2000) Intensive Care Medicine , vol.26 , pp. 660-661
    • Lonnqvist, P.A.1
  • 11
    • 0028044712 scopus 로고
    • Syringe pumps for infusion of vasoactive drugs: Mechanical idiosyncrasies and recommended operating procedures
    • Rooke, G.A. and Bowdle, T.A., 1994, Syringe pumps for infusion of vasoactive drugs: mechanical idiosyncrasies and recommended operating procedures. Anesthesia & Analgesia, 78, 150-156.
    • (1994) Anesthesia & Analgesia , vol.78 , pp. 150-156
    • Rooke, G.A.1    Bowdle, T.A.2
  • 12
    • 0033692930 scopus 로고    scopus 로고
    • The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps
    • Weiss, M., Fischer, J., Neff, T. and Baenziger, O., 2000, The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps. Anaesthesia, 55, 1094-1098.
    • (2000) Anaesthesia , vol.55 , pp. 1094-1098
    • Weiss, M.1    Fischer, J.2    Neff, T.3    Baenziger, O.4
  • 14
    • 0033936276 scopus 로고    scopus 로고
    • Influence of infusion line compliance on drug delivery rate during acute line loop formation
    • Weiss, M., Banziger, O., Neff, T. and Fanconi, S., 2000, Influence of infusion line compliance on drug delivery rate during acute line loop formation. Intensive Care Medicine, 26, 776-779.
    • (2000) Intensive Care Medicine , vol.26 , pp. 776-779
    • Weiss, M.1    Banziger, O.2    Neff, T.3    Fanconi, S.4
  • 15
    • 0034533613 scopus 로고    scopus 로고
    • The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems
    • Schulz, G., Fischer, J., Neff, T., Banziger, O. and Weiss M., 2000, The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems. Anaesthetist, 49, 1018-1023.
    • (2000) Anaesthetist , vol.49 , pp. 1018-1023
    • Schulz, G.1    Fischer, J.2    Neff, T.3    Banziger, O.4    Weiss, M.5
  • 17
    • 0023891568 scopus 로고
    • Nonfatal venous air embolism after contrast-enhanced CT
    • [1.7] Woodring, J.H. and Fried, A.M., 1988, Nonfatal venous air embolism after contrast-enhanced CT. Radiology, 167, 405-407.
    • (1988) Radiology , vol.167 , pp. 405-407
    • Woodring, J.H.1    Fried, A.M.2
  • 18
    • 0019417485 scopus 로고
    • Paraplegia due to peripheral venous air embolus in a neonate: A case report
    • Willis, J., Duncan, C. and Gottschalk, S., 1981, Paraplegia due to peripheral venous air embolus in a neonate: a case report. Pediatrics, 67, 472-473.
    • (1981) Pediatrics , vol.67 , pp. 472-473
    • Willis, J.1    Duncan, C.2    Gottschalk, S.3
  • 19
    • 0026331863 scopus 로고
    • Transcranial Doppler ultrasound identifies patients with right-to-left cardiac or pulmonary shunts
    • Chimowitz, M.I., Nemec, J.J., Marwick, T.H., Lorig, R.J., Furlan, A.J. and Salcedo, E.E., 1991, Transcranial Doppler ultrasound identifies patients with right-to-left cardiac or pulmonary shunts. Neurology, 41, 1902-1904.
    • (1991) Neurology , vol.41 , pp. 1902-1904
    • Chimowitz, M.I.1    Nemec, J.J.2    Marwick, T.H.3    Lorig, R.J.4    Furlan, A.J.5    Salcedo, E.E.6
  • 20
    • 0000332136 scopus 로고
    • Early and late effects on the heart of small amounts of air in the coronary circulation
    • Goldfarb, D. and Bahnson, H.T., 1963, Early and late effects on the heart of small amounts of air in the coronary circulation. Journal of Thoracic Cardiovascular Surgery, 46, 368-378.
    • (1963) Journal of Thoracic Cardiovascular Surgery , vol.46 , pp. 368-378
    • Goldfarb, D.1    Bahnson, H.T.2
  • 21
    • 0023185885 scopus 로고
    • Passage of microbubbles associated with intravenous infusion into the systemic circulation in cyanotic congenital heart disease: Documentation by transesophageal echocardiography
    • Messina, A.C., Leslie, J., Gold, J., Topkins, M.J. and Devereux, R.B., 1987, Passage of microbubbles associated with intravenous infusion into the systemic circulation in cyanotic congenital heart disease: documentation by transesophageal echocardiography. American Journal of Cardiology, 59, 1013-1014.
    • (1987) American Journal of Cardiology , vol.59 , pp. 1013-1014
    • Messina, A.C.1    Leslie, J.2    Gold, J.3    Topkins, M.J.4    Devereux, R.B.5
  • 23
    • 0018383615 scopus 로고
    • Massive air emboli from intravenous infusion pump: Etiology and prevention
    • Abernathy, C.M. and Dickinson, T.C., 1979, Massive air emboli from intravenous infusion pump: etiology and prevention. American Journal of Surgery, 137, 274-275.
    • (1979) American Journal of Surgery , vol.137 , pp. 274-275
    • Abernathy, C.M.1    Dickinson, T.C.2
  • 24
    • 0026629652 scopus 로고
    • Venous air-embolism - Clinical and experimental: Considerations
    • Orebaugh, S.L. 1992, Venous air-embolism - clinical and experimental: considerations. Critical Care Medicine, 20, 1169-1177.
    • (1992) Critical Care Medicine , vol.20 , pp. 1169-1177
    • Orebaugh, S.L.1
  • 25
    • 0031944097 scopus 로고    scopus 로고
    • Serious adverse reactions in neonates receiving intravenous electrolyte solutions - A call for reports
    • Mehta, U., 1998, Serious adverse reactions in neonates receiving intravenous electrolyte solutions - a call for reports. SAMJ, 88, 468-469.
    • (1998) SAMJ , vol.88 , pp. 468-469
    • Mehta, U.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.