메뉴 건너뛰기




Volumn 26, Issue 5, 2005, Pages 486-489

A comparative study of ethylene oxide gas, hydrogen peroxide gas plasma, and low-temperature steam formaldehyde sterilization

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL MARKER; ETHYLENE OXIDE; FORMALDEHYDE; HYDROGEN PEROXIDE;

EID: 18844413529     PISSN: 0899823X     EISSN: None     Source Type: Journal    
DOI: 10.1086/502572     Document Type: Article
Times cited : (36)

References (20)
  • 1
    • 0036833996 scopus 로고    scopus 로고
    • Guidelines for disinfection and sterilization
    • Oie S. Guidelines for disinfection and sterilization [in Japanese]. Nippon Rinsho 2002;60:2121-2125.
    • (2002) Nippon Rinsho , vol.60 , pp. 2121-2125
    • Oie, S.1
  • 2
    • 0036240437 scopus 로고    scopus 로고
    • Microbiological efficacy of Sterrad 100S and LTSF sterilization systems compared with ethylene oxide
    • Caspar MC, Peláez B, Fernández C, Fereres J. Microbiological efficacy of Sterrad 100S and LTSF sterilization systems compared with ethylene oxide. Central Service 2002;10:91-99.
    • (2002) Central Service , vol.10 , pp. 91-99
    • Caspar, M.C.1    Peláez, B.2    Fernández, C.3    Fereres, J.4
  • 5
    • 0346940130 scopus 로고    scopus 로고
    • Experimental and clinical studies on the cleaning and disinfection of endoscopes
    • Sato S, Morishita K, Sasa H, Kinoshita C, Oida M. Experimental and clinical studies on the cleaning and disinfection of endoscopes [in Japanese]. Gastroenterological Endoscopy 1998;40:543-549.
    • (1998) Gastroenterological Endoscopy , vol.40 , pp. 543-549
    • Sato, S.1    Morishita, K.2    Sasa, H.3    Kinoshita, C.4    Oida, M.5
  • 6
    • 0027545425 scopus 로고
    • Sterrad sterilization system: A new technology for instrument sterilization
    • Jacobs P, Kowatsch R. Sterrad sterilization system: a new technology for instrument sterilization. Endoscopic Surgery and Allied Technologies 1993;1:57-58.
    • (1993) Endoscopic Surgery and Allied Technologies , vol.1 , pp. 57-58
    • Jacobs, P.1    Kowatsch, R.2
  • 7
    • 0029559446 scopus 로고
    • Assessment of the efficacy of a low temperature hydrogen peroxide gas plasma sterilization system
    • Kyi MS, Holton J, Ridgway GL. Assessment of the efficacy of a low temperature hydrogen peroxide gas plasma sterilization system. J Hosp Infect 1995;31:275-284.
    • (1995) J Hosp Infect , vol.31 , pp. 275-284
    • Kyi, M.S.1    Holton, J.2    Ridgway, G.L.3
  • 8
    • 0033845248 scopus 로고    scopus 로고
    • Decontamination of minimally invasive surgical endoscopes and accessories
    • Ayliffe G. Decontamination of minimally invasive surgical endoscopes and accessories. J Hosp Infect 2000;45:263-277.
    • (2000) J Hosp Infect , vol.45 , pp. 263-277
    • Ayliffe, G.1
  • 9
    • 0142087673 scopus 로고    scopus 로고
    • Evaluation of a low-temperature steam and formaldehyde sterilizer
    • Kanemitsu K, Kunishima H, Imasaka T, et al. Evaluation of a low-temperature steam and formaldehyde sterilizer. J Hosp Infect 2003;55:47-52.
    • (2003) J Hosp Infect , vol.55 , pp. 47-52
    • Kanemitsu, K.1    Kunishima, H.2    Imasaka, T.3
  • 10
    • 0031761157 scopus 로고    scopus 로고
    • Costs of low-temperature plasma sterilization compared with other sterilization methods
    • Adler S, Scherrer M, Daschner FD. Costs of low-temperature plasma sterilization compared with other sterilization methods. J Hosp Infect 1998;40:125-134.
    • (1998) J Hosp Infect , vol.40 , pp. 125-134
    • Adler, S.1    Scherrer, M.2    Daschner, F.D.3
  • 11
    • 0034108537 scopus 로고    scopus 로고
    • Aeration time following ethylene oxide sterilization for reusable rigid sterilization containers: Concentration of gaseous ethylene oxide in containers
    • Nakata S, Umeshita K, Ueyama H, et al. Aeration time following ethylene oxide sterilization for reusable rigid sterilization containers: concentration of gaseous ethylene oxide in containers. Biomed Instrum Technol 2000;34:121-124.
    • (2000) Biomed Instrum Technol , vol.34 , pp. 121-124
    • Nakata, S.1    Umeshita, K.2    Ueyama, H.3
  • 12
    • 0028609106 scopus 로고
    • Ethylene oxide: IARC monographs programme on the evaluation of carcinogenic risks to humans
    • International Agency for Research on Cancer. Ethylene oxide: IARC monographs programme on the evaluation of carcinogenic risks to humans. IARC Monographs 1994;60:73.
    • (1994) IARC Monographs , vol.60 , pp. 73
  • 13
    • 0032740950 scopus 로고    scopus 로고
    • Hydrogen peroxide: IARC monographs programme on the evaluation of carcinogenic risks to humans
    • International Agency for Research on Cancer. Hydrogen peroxide: IARC monographs programme on the evaluation of carcinogenic risks to humans. IARC Monographs 1999;71:671.
    • (1999) IARC Monographs , vol.71 , pp. 671
  • 14
    • 0029054302 scopus 로고
    • Formaldehyde: IARC monographs programme on the evaluation of carcinogenic risks to humans
    • International Agency for Research on Cancer. Formaldehyde: IARC monographs programme on the evaluation of carcinogenic risks to humans. IARC Monographs 1995;62:217.
    • (1995) IARC Monographs , vol.62 , pp. 217
  • 15
    • 0028299318 scopus 로고
    • APIC guideline for infection prevention and control in flexible endoscopy
    • Martin MA, Reichelderfer M. APIC guideline for infection prevention and control in flexible endoscopy. Am J Infect Control 1994;22:19-38.
    • (1994) Am J Infect Control , vol.22 , pp. 19-38
    • Martin, M.A.1    Reichelderfer, M.2
  • 16
    • 0033628708 scopus 로고    scopus 로고
    • Guidelines on cleaning and disinfection in GI endoscopy: Update 1999
    • Axon A, Jung M, Kruse A, et al. Guidelines on cleaning and disinfection in GI endoscopy: update 1999. Endoscopy 2000;32:77-80.
    • (2000) Endoscopy , vol.32 , pp. 77-80
    • Axon, A.1    Jung, M.2    Kruse, A.3
  • 17
    • 85057348075 scopus 로고    scopus 로고
    • Reprocessing of flexible gastrointestinal endoscopes
    • DiMarino AJ Jr, Goge T, Leung J, et al. Reprocessing of flexible gastrointestinal endoscopes. Gastrointest Endosc 1996;43:540-546.
    • (1996) Gastrointest Endosc , vol.43 , pp. 540-546
    • DiMarino Jr., A.J.1    Goge, T.2    Leung, J.3
  • 18
    • 0026416163 scopus 로고
    • Nosocomial infection and pseudoinfection from contaminated endoscopes and bronchoscopes: Wisconsin and Missouri
    • Centers for Disease Control and Prevention. Nosocomial infection and pseudoinfection from contaminated endoscopes and bronchoscopes: Wisconsin and Missouri. MMWR 1991;40:675-678.
    • (1991) MMWR , vol.40 , pp. 675-678
  • 19
    • 0027076628 scopus 로고
    • Transmission of infection by gastrointestinal endoscopy
    • Spach DH, Silverstein FE, Stamm WE. Transmission of infection by gastrointestinal endoscopy. Ann Intern Med 1993;118:117-128.
    • (1993) Ann Intern Med , vol.118 , pp. 117-128
    • Spach, D.H.1    Silverstein, F.E.2    Stamm, W.E.3
  • 20
    • 0033538360 scopus 로고    scopus 로고
    • Bronchoscopy-related infections and pseudoinfections: New York, 1996 and 1998
    • Centers for Disease Control and Prevention. Bronchoscopy-related infections and pseudoinfections: New York, 1996 and 1998. MMWR 1999;48:557-560.
    • (1999) MMWR , vol.48 , pp. 557-560


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.