-
1
-
-
0025371157
-
Adverse reactions to ionic and nonionic contrast media
-
Katayama H, Yamaguchi K, Kozuka T, Tashima T, Seez P, Matuura K. Adverse reactions to ionic and nonionic contrast media. Radiology 1990; 175:621-628.
-
(1990)
Radiology
, vol.175
, pp. 621-628
-
-
Katayama, H.1
Yamaguchi, K.2
Kozuka, T.3
Tashima, T.4
Seez, P.5
Matuura, K.6
-
2
-
-
0027205040
-
Gadopentate dimeglumine as an alternative contrast material for use in angiography
-
Kinno Y, Odagiri K, Andoh K, Itoh Y, Tarao K. Gadopentate dimeglumine as an alternative contrast material for use in angiography. AJR Am J Roentgenol 1993; 160:1293-1294.
-
(1993)
AJR Am J Roentgenol
, vol.160
, pp. 1293-1294
-
-
Kinno, Y.1
Odagiri, K.2
Andoh, K.3
Itoh, Y.4
Tarao, K.5
-
3
-
-
0032060393
-
Gd-DTPA as an alternative contrast agent in conventional and interventional radiology
-
Vehmas T, Markolla T. Gd-DTPA as an alternative contrast agent in conventional and interventional radiology. Acta Radiol 1998; 39:223-226.
-
(1998)
Acta Radiol
, vol.39
, pp. 223-226
-
-
Vehmas, T.1
Markolla, T.2
-
4
-
-
0032608921
-
Gadolinium dimeglumine: An alternative contrast agent for digital substraction angiography
-
Hammer FD, Goffette PP, Malaise J, Mathurin P. Gadolinium dimeglumine: an alternative contrast agent for digital substraction angiography. Eur Radiol 1999; 9:128-136.
-
(1999)
Eur Radiol
, vol.9
, pp. 128-136
-
-
Hammer, F.D.1
Goffette, P.P.2
Malaise, J.3
Mathurin, P.4
-
5
-
-
0033839697
-
Gadolinium-DTPA as x-ray contrast medium in clinical studies
-
Albrecht T, Dawson P. Gadolinium-DTPA as x-ray contrast medium in clinical studies. Br J Radiol 2000; 73:878-882.
-
(2000)
Br J Radiol
, vol.73
, pp. 878-882
-
-
Albrecht, T.1
Dawson, P.2
-
6
-
-
0036242434
-
Gadolinium chelates in angiography and interventional radiology: A useful alternative to iodinated contrast media for angiography
-
Spinosa DJ, Kaufmann JA, Hartwell GD. Gadolinium chelates in angiography and interventional radiology: a useful alternative to iodinated contrast media for angiography. Radiology 2002; 223:319-325.
-
(2002)
Radiology
, vol.223
, pp. 319-325
-
-
Spinosa, D.J.1
Kaufmann, J.A.2
Hartwell, G.D.3
-
7
-
-
0024506234
-
Gd-DTPA as a contrast agent in CT
-
Bloem JL, Wondergem J. Gd-DTPA as a contrast agent in CT. Radiology 1989; 171:578-579.
-
(1989)
Radiology
, vol.171
, pp. 578-579
-
-
Bloem, J.L.1
Wondergem, J.2
-
8
-
-
0025787733
-
Comparison of iodinated and noniodinated contrast media in computed tomography
-
Zwicker C, Langer M, Langer R, Keske U. Comparison of iodinated and noniodinated contrast media in computed tomography. Invest Radiol 1991; 26(suppl 1):S162-S164.
-
(1991)
Invest Radiol
, vol.26
, Issue.SUPPL. 1
-
-
Zwicker, C.1
Langer, M.2
Langer, R.3
Keske, U.4
-
9
-
-
0031460127
-
Attenuation characteristics and application of gadolinium-DTPA in fast helical computed tomography
-
Luboldt W, De-Santis M, von-Smekal A, Reiser M. Attenuation characteristics and application of gadolinium-DTPA in fast helical computed tomography. Invest Radiol 1997; 32:690-695.
-
(1997)
Invest Radiol
, vol.32
, pp. 690-695
-
-
Luboldt, W.1
De-Santis, M.2
Von-Smekal, A.3
Reiser, M.4
-
10
-
-
0033044150
-
Gadolinium as a CT contrast agent: Assessment in a porcine model
-
Gierada DS, Bae KT. Gadolinium as a CT contrast agent: assessment in a porcine model. Radiology 1999; 210:829-834.
-
(1999)
Radiology
, vol.210
, pp. 829-834
-
-
Gierada, D.S.1
Bae, K.T.2
-
11
-
-
0036870727
-
Gadopentate dimeglumine is potentially an alternative contrast agent for three-dimensional computed tomography angiography with multidetector-row helical scanning
-
Gupta AK, Alberico RA, Litwin A, Knater P, Grossman ZD. Gadopentate dimeglumine is potentially an alternative contrast agent for three-dimensional computed tomography angiography with multidetector-row helical scanning. J Comput Assist Tomogr 2002; 26:869-874.
-
(2002)
J Comput Assist Tomogr
, vol.26
, pp. 869-874
-
-
Gupta, A.K.1
Alberico, R.A.2
Litwin, A.3
Knater, P.4
Grossman, Z.D.5
-
13
-
-
0032725642
-
Gd-DTPA: A possible alternative contrast agent for use in CT during intraarterial administration
-
Kawano T, Ishijima H, Nakajima T, Aoki J, Endo K. Gd-DTPA: a possible alternative contrast agent for use in CT during intraarterial administration. J Comput Assist Tomogr 1999; 23:939-940.
-
(1999)
J Comput Assist Tomogr
, vol.23
, pp. 939-940
-
-
Kawano, T.1
Ishijima, H.2
Nakajima, T.3
Aoki, J.4
Endo, K.5
-
14
-
-
17044451495
-
Gadopentate dimeglumine: A possible alternative contrast agent for CT angiography of the aorta
-
Pena CS, Kaufman JA, Geller SC, Waltman AC. Gadopentate dimeglumine: a possible alternative contrast agent for CT angiography of the aorta. J Comput Assist Tomogr 1999; 23:23-24.
-
(1999)
J Comput Assist Tomogr
, vol.23
, pp. 23-24
-
-
Pena, C.S.1
Kaufman, J.A.2
Geller, S.C.3
Waltman, A.C.4
-
15
-
-
0036870085
-
Gadolinium-enhanced multidetector CT angiography of the thoracoabdominal aorta
-
Karcaaltincaba M, Foley WD. Gadolinium-enhanced multidetector CT angiography of the thoracoabdominal aorta. J Comput Assist Tomogr 2002; 26:875-878.
-
(2002)
J Comput Assist Tomogr
, vol.26
, pp. 875-878
-
-
Karcaaltincaba, M.1
Foley, W.D.2
-
16
-
-
0034762345
-
Demonstration of pulmonary embolism with dynamic gadolinium-enhanced spiral CT
-
Coche EE, Hammer FD, Gofette PP. Demonstration of pulmonary embolism with dynamic gadolinium-enhanced spiral CT. Eur Radiol 2001; 11:2306-2309.
-
(2001)
Eur Radiol
, vol.11
, pp. 2306-2309
-
-
Coche, E.E.1
Hammer, F.D.2
Gofette, P.P.3
-
17
-
-
0026640165
-
Central pulmonary thromboembolism: Diagnosis with spiral volumetric CT with the single breath hold technique-comparison with pulmonary angiography
-
Remy-Jardin M, Remy J, Wattinne L, Giraud F. Central pulmonary thromboembolism: diagnosis with spiral volumetric CT with the single breath hold technique-comparison with pulmonary angiography. Radiology 1992; 185:381-387.
-
(1992)
Radiology
, vol.185
, pp. 381-387
-
-
Remy-Jardin, M.1
Remy, J.2
Wattinne, L.3
Giraud, F.4
-
18
-
-
0032828139
-
Safety of magnetic resonance imaging contrast agents
-
Shellock FG, Kanal E. Safety of magnetic resonance imaging contrast agents. J Magn Reson Imaging 1999; 10:477-484.
-
(1999)
J Magn Reson Imaging
, vol.10
, pp. 477-484
-
-
Shellock, F.G.1
Kanal, E.2
-
19
-
-
0028800979
-
Evaluation of gadobutrol in a rabbit model as a new lanthanide contrast agent for computed tomography
-
Schmitz SA, Wagner S, Schuhmann-Giampieri G, Wolf KJ. Evaluation of gadobutrol in a rabbit model as a new lanthanide contrast agent for computed tomography. Invest Radiol 1995; 30:644-649.
-
(1995)
Invest Radiol
, vol.30
, pp. 644-649
-
-
Schmitz, S.A.1
Wagner, S.2
Schuhmann-Giampieri, G.3
Wolf, K.J.4
-
20
-
-
0028500520
-
MRI evaluation of "solitary" brain metastases with triple-dose gadoteridol: Comparison with contrast-enhanced CT and conventional-dose gadopentate dimeglumine MRI studies in the same patients
-
Kuhn MJ, Hammer GM, Swenson LC, Youssef HT, Gleason TJ. MRI evaluation of "solitary" brain metastases with triple-dose gadoteridol: comparison with contrast-enhanced CT and conventional-dose gadopentate dimeglumine MRI studies in the same patients. Comput Med Imaging Graph 1994; 18:391-399.
-
(1994)
Comput Med Imaging Graph
, vol.18
, pp. 391-399
-
-
Kuhn, M.J.1
Hammer, G.M.2
Swenson, L.C.3
Youssef, H.T.4
Gleason, T.J.5
-
21
-
-
0031693017
-
A multi-centre longitudinal study comparing the sensitivity of monthly MRI after standard and triple dose gadolinium-DTPA for monitoring disease activity in multiple sclerosis: Implications for phase II clinical trials
-
Filippi M, Rovaris M, Capra R, et al. A multi-centre longitudinal study comparing the sensitivity of monthly MRI after standard and triple dose gadolinium-DTPA for monitoring disease activity in multiple sclerosis: implications for phase II clinical trials. Brain 1998; 121:2011-2020.
-
(1998)
Brain
, vol.121
, pp. 2011-2020
-
-
Filippi, M.1
Rovaris, M.2
Capra, R.3
-
22
-
-
0036781912
-
Gadolinium-containing contrast media for radiographic examinations: A position paper
-
Thomsen HS, Almen T, Morcos SK. Gadolinium-containing contrast media for radiographic examinations: a position paper. Eur Radiol 2002; 12:2600-2605.
-
(2002)
Eur Radiol
, vol.12
, pp. 2600-2605
-
-
Thomsen, H.S.1
Almen, T.2
Morcos, S.K.3
-
23
-
-
0025719706
-
Safety and tolerance after intravenous administration of 0.3 mmol/kg Gd-DTPA: Results of a randomized, controlled clinical trial
-
Niendorf HP, Haustein J, Louton AT, et al. Safety and tolerance after intravenous administration of 0.3 mmol/kg Gd-DTPA: results of a randomized, controlled clinical trial. Invest Radiol 1991; 26(suppl 1): S221-S223.
-
(1991)
Invest Radiol
, vol.26
, Issue.SUPPL. 1
-
-
Niendorf, H.P.1
Haustein, J.2
Louton, A.T.3
-
24
-
-
0026531049
-
Renal tolerance of Gd-DTPA dimeglumine in patients with chronic renal failure
-
Haustein J, Niendorp HP, Krestin G, et al. Renal tolerance of Gd-DTPA dimeglumine in patients with chronic renal failure. Invest Radiol 1992; 27:153-156.
-
(1992)
Invest Radiol
, vol.27
, pp. 153-156
-
-
Haustein, J.1
Niendorp, H.P.2
Krestin, G.3
-
25
-
-
0029680085
-
Nephrotoxicity of high-dose gadolinium compared with iodinated contrast
-
Prince MR, Arnoldus C, Frisoli JK. Nephrotoxicity of high-dose gadolinium compared with iodinated contrast. J Magn Reson Imaging 1996; 6:162-166.
-
(1996)
J Magn Reson Imaging
, vol.6
, pp. 162-166
-
-
Prince, M.R.1
Arnoldus, C.2
Frisoli, J.K.3
-
26
-
-
0033045796
-
Pharmacokinetics, safety, and tolerability of gadoversetamide injection (Optimark) in subjects with central nervous system or liver pathology and varying degrees of renal function
-
Swan SK, Baker JF, Free R, et al. Pharmacokinetics, safety, and tolerability of gadoversetamide injection (Optimark) in subjects with central nervous system or liver pathology and varying degrees of renal function. J Magn Reson Imaging 1999; 9:317-321.
-
(1999)
J Magn Reson Imaging
, vol.9
, pp. 317-321
-
-
Swan, S.K.1
Baker, J.F.2
Free, R.3
-
27
-
-
0023753548
-
New and old contrast agents: Physiology and nephrotoxicity
-
Katzberg R. New and old contrast agents: physiology and nephrotoxicity. Urol Radiol 1988; 10:6-11.
-
(1988)
Urol Radiol
, vol.10
, pp. 6-11
-
-
Katzberg, R.1
-
28
-
-
0031910832
-
Contrast-medium induced renal failure
-
Solomon R. Contrast-medium induced renal failure. Kidney Int 1998; 53:230-242.
-
(1998)
Kidney Int
, vol.53
, pp. 230-242
-
-
Solomon, R.1
-
29
-
-
0031000514
-
Reports on contrast media reactions: Analysis of data from reports of the U.S. Food and Drug Administration [published correction appears in Radiology 1997; 204:876.]
-
Lasser EC, Lyon SG, Berry CC. Reports on contrast media reactions: analysis of data from reports of the U.S. Food and Drug Administration [published correction appears in Radiology 1997; 204:876.]. Radiology 1997; 203:605-610.
-
(1997)
Radiology
, vol.203
, pp. 605-610
-
-
Lasser, E.C.1
Lyon, S.G.2
Berry, C.C.3
|