메뉴 건너뛰기




Volumn 65, Issue 3, 2005, Pages 221-225

Nickel contamination from an intravenous catheter used for infusion

Author keywords

Allergy; Blood sampling; Quality control; Ringer acetate; Stainless steel

Indexed keywords

CHROMIUM; MOLYBDENUM; NICKEL; RINGER ACETATE;

EID: 18844378346     PISSN: 00365513     EISSN: None     Source Type: Journal    
DOI: 10.1080/00365510510013578     Document Type: Review
Times cited : (7)

References (24)
  • 1
    • 0034816083 scopus 로고    scopus 로고
    • Assessment of the contamination from devices used for sampling and storage of whole blood and serum for element analysis
    • Rodushkin I, Ödman F. Assessment of the contamination from devices used for sampling and storage of whole blood and serum for element analysis. J Trace Elem Med Biol 2001;15:40-5.
    • (2001) J Trace Elem Med Biol , vol.15 , pp. 40-45
    • Rodushkin, I.1    Ödman, F.2
  • 2
    • 0036719501 scopus 로고    scopus 로고
    • A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep
    • Frisken KW, Dandie GW, Lugowski S, Jordan G. A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep. Aust Dent J 2002;47:214-7.
    • (2002) Aust Dent J , vol.47 , pp. 214-217
    • Frisken, K.W.1    Dandie, G.W.2    Lugowski, S.3    Jordan, G.4
  • 3
    • 0031727764 scopus 로고    scopus 로고
    • Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study
    • Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Black J, et al. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am 1998;80:1447-58.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 1447-1458
    • Jacobs, J.J.1    Skipor, A.K.2    Patterson, L.M.3    Hallab, N.J.4    Paprosky, W.G.5    Black, J.6
  • 5
    • 0028999336 scopus 로고
    • Release of hexavalent chromium from corrosion of stainless steel and cobalt-chromium alloys
    • Merritt K, Brown SA. Release of hexavalent chromium from corrosion of stainless steel and cobalt-chromium alloys. J Biomed Mater Res 1995;29:627-33.
    • (1995) J Biomed Mater Res , vol.29 , pp. 627-633
    • Merritt, K.1    Brown, S.A.2
  • 6
    • 0344306477 scopus 로고    scopus 로고
    • Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: A comparison between short- and medium-term results
    • Savarino L, Granchi D, Ciapetti G, Cenni E, Greco M, Rotini R, et al. Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: a comparison between short- and medium-term results. J Biomed Mater Res 2003;66A:450-6.
    • (2003) J Biomed Mater Res , vol.66 A , pp. 450-456
    • Savarino, L.1    Granchi, D.2    Ciapetti, G.3    Cenni, E.4    Greco, M.5    Rotini, R.6
  • 7
    • 0036380582 scopus 로고    scopus 로고
    • Ion release in patients with metal-on-metal hip bearings in total joint replacement: A comparison with metal-on-polyethylene bearings
    • Savarino L, Granchi D, Ciapetti G, Cenni E, Nardi Pantoli A, Rotini R, et al. Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. J Biomed Mater Res 2002;63:467-74.
    • (2002) J Biomed Mater Res , vol.63 , pp. 467-474
    • Savarino, L.1    Granchi, D.2    Ciapetti, G.3    Cenni, E.4    Nardi Pantoli, A.5    Rotini, R.6
  • 8
    • 0021974532 scopus 로고
    • Fretting corrosion of plates and screws: An in vitro test method
    • Fraker A, Griffin C, editors. Philadelphia: ASTM
    • Brown S, Merritt K. Fretting corrosion of plates and screws: an in vitro test method. In: Fraker A, Griffin C, editors. Corrosion and degradation of implant materials. Philadelphia: ASTM, 1985. pp 105-16.
    • (1985) Corrosion and Degradation of Implant Materials , pp. 105-116
    • Brown, S.1    Merritt, K.2
  • 9
    • 12144288260 scopus 로고    scopus 로고
    • Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates
    • Krischak GD, Gebhard F, Mohr W, Krivan V, Ignatius A, Beck A, et al. Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates. Arch Orthop Trauma Surg 2004;124:104-13.
    • (2004) Arch Orthop Trauma Surg , vol.124 , pp. 104-113
    • Krischak, G.D.1    Gebhard, F.2    Mohr, W.3    Krivan, V.4    Ignatius, A.5    Beck, A.6
  • 10
    • 0030130652 scopus 로고    scopus 로고
    • Evaluation of soft tissue reactions at the interface of titanium limited contact dynamic compression plate implants with different surface treatments: An experimental sheep study
    • Ungersböck A, Pohler OE, Perren SM. Evaluation of soft tissue reactions at the interface of titanium limited contact dynamic compression plate implants with different surface treatments: an experimental sheep study. Biomaterials 1996;17:797-806.
    • (1996) Biomaterials , vol.17 , pp. 797-806
    • Ungersböck, A.1    Pohler, O.E.2    Perren, S.M.3
  • 12
    • 0034597889 scopus 로고    scopus 로고
    • Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
    • Köster R, Vieluf D, Kiehn M, Sommerauer M, Kähler J, Baldus S, et al. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 2000;356:1895-7.
    • (2000) Lancet , vol.356 , pp. 1895-1897
    • Köster, R.1    Vieluf, D.2    Kiehn, M.3    Sommerauer, M.4    Kähler, J.5    Baldus, S.6
  • 13
    • 0033814142 scopus 로고    scopus 로고
    • A triple assay technique for the evaluation of metal-induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty
    • Hallab NJ, Mikecz K, Jacobs JJ. A triple assay technique for the evaluation of metal-induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty. J Biomed Mater Res 2000;53:480-9.
    • (2000) J Biomed Mater Res , vol.53 , pp. 480-489
    • Hallab, N.J.1    Mikecz, K.2    Jacobs, J.J.3
  • 14
  • 15
    • 0034142516 scopus 로고    scopus 로고
    • Corrosion of and changes in biological effects of cobalt chrome alloy and 316L stainless steel prosthetic particles with age
    • Haynes DR, Crotti TN, Haywood MR. Corrosion of and changes in biological effects of cobalt chrome alloy and 316L stainless steel prosthetic particles with age. J Biomed Mater Res 2000;49:167-75.
    • (2000) J Biomed Mater Res , vol.49 , pp. 167-175
    • Haynes, D.R.1    Crotti, T.N.2    Haywood, M.R.3
  • 16
    • 0036774766 scopus 로고    scopus 로고
    • Positive cytokine production in failed metal-on-metal total hip replacements
    • Campbell PA, Wang M, Amstutz HC, Goodman SB. Positive cytokine production in failed metal-on-metal total hip replacements. Acta Orthop Scand 2002;73:506-12.
    • (2002) Acta Orthop Scand , vol.73 , pp. 506-512
    • Campbell, P.A.1    Wang, M.2    Amstutz, H.C.3    Goodman, S.B.4
  • 17
    • 0037376508 scopus 로고    scopus 로고
    • Metal ions induce bone-resorbing cytokine production through the redox pathway in synoviocytes and bone marrow macrophages
    • Niki Y, Matsumoto H, Suda Y, Otani T, Fujikawa K, Toyama Y, et al. Metal ions induce bone-resorbing cytokine production through the redox pathway in synoviocytes and bone marrow macrophages. Biomaterials 2003;24:1447-57.
    • (2003) Biomaterials , vol.24 , pp. 1447-1457
    • Niki, Y.1    Matsumoto, H.2    Suda, Y.3    Otani, T.4    Fujikawa, K.5    Toyama, Y.6
  • 19
    • 0035134409 scopus 로고    scopus 로고
    • Development of a routine method for the determination of trace metals in whole blood by magnetic sector inductively coupled plasma mass spectrometry with particular relevance to patients with total hip and knee arthroplasty
    • Case CP, Ellis L, Turner JC, Fairman B. Development of a routine method for the determination of trace metals in whole blood by magnetic sector inductively coupled plasma mass spectrometry with particular relevance to patients with total hip and knee arthroplasty. Clin Chem 2001;47:275-80.
    • (2001) Clin Chem , vol.47 , pp. 275-280
    • Case, C.P.1    Ellis, L.2    Turner, J.C.3    Fairman, B.4
  • 21
    • 0028573586 scopus 로고
    • The assessment of reference values for elements in human biological tissues and fluids: A systematic review
    • Caroli S, Alimonti E, Coni E, Petrucci F, Senofonte O, Violante N. The assessment of reference values for elements in human biological tissues and fluids: a systematic review. Crit Rev Anal Chem 1994;24:363-98.
    • (1994) Crit Rev Anal Chem , vol.24 , pp. 363-398
    • Caroli, S.1    Alimonti, E.2    Coni, E.3    Petrucci, F.4    Senofonte, O.5    Violante, N.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.