-
2
-
-
0007807449
-
The pulley system
-
J.M. Hunter, J.F. Cook, N. Ochiai, J.J. Konikoff, R.J. Merklin, and G.A. Mackin The pulley system Orthop Trans 4 1980 4
-
(1980)
Orthop Trans
, vol.4
, pp. 4
-
-
Hunter, J.M.1
Cook, J.F.2
Ochiai, N.3
Konikoff, J.J.4
Merklin, R.J.5
MacKin, G.A.6
-
4
-
-
0029926703
-
Mechanical analysis of the palmar aponeurosis pulley in human cadavers
-
C. Phillips, and D. Mass Mechanical analysis of the palmar aponeurosis pulley in human cadavers J Hand Surg [Am] 21 2 1996 240 244
-
(1996)
J Hand Surg [Am]
, vol.21
, Issue.2
, pp. 240-244
-
-
Phillips, C.1
Mass, D.2
-
5
-
-
0023730595
-
Anatomy of the finger flexor tendon sheath and pulley system
-
J.R. Doyle Anatomy of the finger flexor tendon sheath and pulley system J Hand Surg [Am] 13 4 1988 473 484
-
(1988)
J Hand Surg [Am]
, vol.13
, Issue.4
, pp. 473-484
-
-
Doyle, J.R.1
-
6
-
-
0024561809
-
Anatomy of the flexor tendon sheath and pulley system: A current review
-
J.R. Doyle Anatomy of the flexor tendon sheath and pulley system: a current review J Hand Surg [Am] 14 2 Pt 2 1989 349 351
-
(1989)
J Hand Surg [Am]
, vol.14
, Issue.2 PART 2
, pp. 349-351
-
-
Doyle, J.R.1
-
7
-
-
0032451562
-
Anatomy and histology of the A5 pulley
-
B.M. Katzman, D.M. Klein, T.C. Garven, D.A. Caligiuri, J. Kung, and E.D. Collins Anatomy and histology of the A5 pulley J Hand Surg [Am] 23 4 1998 653 657
-
(1998)
J Hand Surg [Am]
, vol.23
, Issue.4
, pp. 653-657
-
-
Katzman, B.M.1
Klein, D.M.2
Garven, T.C.3
Caligiuri, D.A.4
Kung, J.5
Collins, E.D.6
-
8
-
-
0022283341
-
Digital flexor tendon sheath: An anatomic study
-
B. Strauch, and W. de Moura Digital flexor tendon sheath: an anatomic study J Hand Surg [Am] 10 6 Pt 1 1985 785 789
-
(1985)
J Hand Surg [Am]
, vol.10
, Issue.6 PART 1
, pp. 785-789
-
-
Strauch, B.1
De Moura, W.2
-
9
-
-
0017641994
-
Strength of human pulleys
-
P.R. Manske, and P.A. Lesker Strength of human pulleys Hand 9 2 1977 147 152
-
(1977)
Hand
, vol.9
, Issue.2
, pp. 147-152
-
-
Manske, P.R.1
Lesker, P.A.2
-
10
-
-
0025741832
-
Biomechanics of pulley reconstruction
-
E.L. Hume, D.T. Hutchinson, S.A. Jaeger, and J.M. Hunter Biomechanics of pulley reconstruction J Hand Surg [Am] 16 4 1991 722 730
-
(1991)
J Hand Surg [Am]
, vol.16
, Issue.4
, pp. 722-730
-
-
Hume, E.L.1
Hutchinson, D.T.2
Jaeger, S.A.3
Hunter, J.M.4
-
11
-
-
0024800265
-
Functional anatomy of the human digital flexor pulley system
-
G.T. Lin, P.C. Amadio, K.N. An, and W.P. Cooney Functional anatomy of the human digital flexor pulley system J Hand Surg [Am] 14 6 1989 949 956
-
(1989)
J Hand Surg [Am]
, vol.14
, Issue.6
, pp. 949-956
-
-
Lin, G.T.1
Amadio, P.C.2
An, K.N.3
Cooney, W.P.4
-
12
-
-
0022602965
-
Effect of pulley excision on flexor tendon biomechanics
-
W.W. Peterson, P.R. Manske, B.A. Bollinger, P.A. Lesker, and J.A. McCarthy Effect of pulley excision on flexor tendon biomechanics J Orthop Res 4 1 1986 96 101
-
(1986)
J Orthop Res
, vol.4
, Issue.1
, pp. 96-101
-
-
Peterson, W.W.1
Manske, P.R.2
Bollinger, B.A.3
Lesker, P.A.4
McCarthy, J.A.5
-
13
-
-
0023134421
-
Flexor tendon injuries. Part 4. Staged flexor tendon reconstruction and restoration of the flexor pulley
-
J.W. Strickland Flexor tendon injuries. Part 4. Staged flexor tendon reconstruction and restoration of the flexor pulley Orthop Rev 16 2 1987 78 90
-
(1987)
Orthop Rev
, vol.16
, Issue.2
, pp. 78-90
-
-
Strickland, J.W.1
-
14
-
-
0014468284
-
Experimental study of optimal location of flexor tendon pulleys
-
N.J. Barton Experimental study of optimal location of flexor tendon pulleys Plast Reconstr Surg 43 1969 125 129
-
(1969)
Plast Reconstr Surg
, vol.43
, pp. 125-129
-
-
Barton, N.J.1
-
15
-
-
0029993292
-
Efficiency of the flexor tendon pulley system in human cadaver hands
-
D. Rispler, D. Greenwald, S. Shumway, C. Allan, and D. Mass Efficiency of the flexor tendon pulley system in human cadaver hands J Hand Surg [Am] 21 3 1996 444 450
-
(1996)
J Hand Surg [Am]
, vol.21
, Issue.3
, pp. 444-450
-
-
Rispler, D.1
Greenwald, D.2
Shumway, S.3
Allan, C.4
Mass, D.5
-
17
-
-
0016144199
-
Reconstruction of digital pulleys
-
R.C. Wray Jr., and P.M. Weeks Reconstruction of digital pulleys Plast Reconstr Surg 53 5 1974 534 536
-
(1974)
Plast Reconstr Surg
, vol.53
, Issue.5
, pp. 534-536
-
-
Wray Jr., R.C.1
Weeks, P.M.2
-
18
-
-
0024444914
-
A mechanical study of six digital pulley reconstruction techniques: Part II. Strength of individual reconstructions
-
C.J. Widstrom, J.R. Doyle, G. Johnson, P.R. Manske, and R. McGee A mechanical study of six digital pulley reconstruction techniques: Part II. Strength of individual reconstructions J Hand Surg [Am] 14 5 1989 826 829
-
(1989)
J Hand Surg [Am]
, vol.14
, Issue.5
, pp. 826-829
-
-
Widstrom, C.J.1
Doyle, J.R.2
Johnson, G.3
Manske, P.R.4
McGee, R.5
-
19
-
-
0024434592
-
Biomechanical analysis of finger flexor pulley reconstruction
-
G.T. Lin, P.C. Amadio, K.N. An, W.P. Cooney, and E.Y. Chao Biomechanical analysis of finger flexor pulley reconstruction J Hand Surg [Br] 14 3 1989 278 282
-
(1989)
J Hand Surg [Br]
, vol.14
, Issue.3
, pp. 278-282
-
-
Lin, G.T.1
Amadio, P.C.2
An, K.N.3
Cooney, W.P.4
Chao, E.Y.5
-
20
-
-
0032468078
-
Flexor tendon-pulley interaction after annular pulley reconstruction: A biomechanical study in a dog model in vivo
-
J. Nishida, J.G. Seiler, P.C. Amadio, and K.N. An Flexor tendon-pulley interaction after annular pulley reconstruction: a biomechanical study in a dog model in vivo J Hand Surg [Am] 23 2 1998 279 284
-
(1998)
J Hand Surg [Am]
, vol.23
, Issue.2
, pp. 279-284
-
-
Nishida, J.1
Seiler, J.G.2
Amadio, P.C.3
An, K.N.4
-
21
-
-
0032467407
-
Flexor tendon-pulley interaction after pulley reconstruction: A biomechanical study in a human model in vitro
-
J. Nishida, P.C. Amadio, P.C. Bettinger, and K.N. An Flexor tendon-pulley interaction after pulley reconstruction: a biomechanical study in a human model in vitro J Hand Surg [Am] 23 4 1998 665 672
-
(1998)
J Hand Surg [Am]
, vol.23
, Issue.4
, pp. 665-672
-
-
Nishida, J.1
Amadio, P.C.2
Bettinger, P.C.3
An, K.N.4
-
22
-
-
0026659827
-
Digital pulley reconstruction with expanded polytetrafluoroethylene (PTFE) membrane at the time of tenorrhaphy in an experimental animal model
-
N.B. Semer, B.K. Bartle, G.M. Telepun, and N.H. Goldberg Digital pulley reconstruction with expanded polytetrafluoroethylene (PTFE) membrane at the time of tenorrhaphy in an experimental animal model J Hand Surg [Am] 17 3 1992 547 550
-
(1992)
J Hand Surg [Am]
, vol.17
, Issue.3
, pp. 547-550
-
-
Semer, N.B.1
Bartle, B.K.2
Telepun, G.M.3
Goldberg, N.H.4
-
23
-
-
0014253773
-
Silicone pulleys and underlays in tendon surgery
-
K.F. Bader, G. Sethi, and J.W. Curtin Silicone pulleys and underlays in tendon surgery Plast Reconstr Surg 41 1968 157 164
-
(1968)
Plast Reconstr Surg
, vol.41
, pp. 157-164
-
-
Bader, K.F.1
Sethi, G.2
Curtin, J.W.3
-
24
-
-
18844436112
-
Positioning of the pulley mechanism when reconstructing deep flexor tendons of the fingers
-
K.A. Solonen, and P. Hoyer Positioning of the pulley mechanism when reconstructing deep flexor tendons of the fingers Acta Orthop Scand 38 1967 321 328
-
(1967)
Acta Orthop Scand
, vol.38
, pp. 321-328
-
-
Solonen, K.A.1
Hoyer, P.2
-
25
-
-
0024425225
-
A mechanical study of six digital pulley reconstruction techniques. Part I. Mechanical effectiveness
-
C.J. Widstrom, G. Johnson, J.R. Doyle, P.R. Manske, and P. Inhofe A mechanical study of six digital pulley reconstruction techniques. Part I. Mechanical effectiveness J Hand Surg [Am] 14 5 1989 821 825
-
(1989)
J Hand Surg [Am]
, vol.14
, Issue.5
, pp. 821-825
-
-
Widstrom, C.J.1
Johnson, G.2
Doyle, J.R.3
Manske, P.R.4
Inhofe, P.5
-
26
-
-
0023406834
-
Three-loop technique for A2 pulley reconstruction
-
I. Okutsu, S. Ninomiya, S. Hiraki, H. Inanami, and N. Kuroshima Three-loop technique for A2 pulley reconstruction J Hand Surg [Am] 12 5 Pt 1 1987 790 794
-
(1987)
J Hand Surg [Am]
, vol.12
, Issue.5 PART 1
, pp. 790-794
-
-
Okutsu, I.1
Ninomiya, S.2
Hiraki, S.3
Inanami, H.4
Kuroshima, N.5
-
27
-
-
0016786593
-
Tendon and pulleys at the metacarpophalangeal joint of a finger
-
P.W. Brand, K.C. Cranor, and J.C. Ellis Tendon and pulleys at the metacarpophalangeal joint of a finger J Bone Joint Surg 57 6 1975 779 784
-
(1975)
J Bone Joint Surg
, vol.57
, Issue.6
, pp. 779-784
-
-
Brand, P.W.1
Cranor, K.C.2
Ellis, J.C.3
-
28
-
-
0343409514
-
The pulley system: Rationale for reconstruction
-
J.W. Strickland J.B. Steichen CV Mosby St. Louis
-
J.M. Hunter, and J.F. Cook Jr. The pulley system: rationale for reconstruction J.W. Strickland J.B. Steichen Difficult problems in hand surgery 1982 CV Mosby St. Louis 94 102
-
(1982)
Difficult Problems in Hand Surgery
, pp. 94-102
-
-
Hunter, J.M.1
Cook Jr., J.F.2
-
29
-
-
0016798966
-
The role of the digital synovial sheath in tendon grafting. An experimental and clinical study on autologous tendon grafting in the digit
-
O. Eiken, G. Lundborg, and F. Rank The role of the digital synovial sheath in tendon grafting. An experimental and clinical study on autologous tendon grafting in the digit Scand J Plast Reconstr Surg 9 3 1975 182 189
-
(1975)
Scand J Plast Reconstr Surg
, vol.9
, Issue.3
, pp. 182-189
-
-
Eiken, O.1
Lundborg, G.2
Rank, F.3
-
30
-
-
0017612009
-
Synovium as a nutritional medium in tendon grafting
-
G. Lundborg, O. Eiken, and F. Rank Synovium as a nutritional medium in tendon grafting Handchirurgie 9 3 1977 107 111
-
(1977)
Handchirurgie
, vol.9
, Issue.3
, pp. 107-111
-
-
Lundborg, G.1
Eiken, O.2
Rank, F.3
-
31
-
-
0017688878
-
The vascularization of human flexor tendons within the digital synovial sheath region - Structural and functional aspects
-
G. Lundborg, R. Myrhage, and B. Rydevik The vascularization of human flexor tendons within the digital synovial sheath region - structural and functional aspects J Hand Surg [Am] 2 6 1977 417 427
-
(1977)
J Hand Surg [Am]
, vol.2
, Issue.6
, pp. 417-427
-
-
Lundborg, G.1
Myrhage, R.2
Rydevik, B.3
-
32
-
-
0018720424
-
Experimental studies in chickens on the initial nutrition of tendon grafts
-
P.R. Manske, P.A. Lesker, and K. Bridwell Experimental studies in chickens on the initial nutrition of tendon grafts J Hand Surg [Am] 4 6 1979 565 575
-
(1979)
J Hand Surg [Am]
, vol.4
, Issue.6
, pp. 565-575
-
-
Manske, P.R.1
Lesker, P.A.2
Bridwell, K.3
-
33
-
-
0017735235
-
Tendon healing: An experimental model in the dog
-
C.L. McDowell, and D.M. Snyder Tendon healing: an experimental model in the dog J Hand Surg [Am] 2 2 1977 122 126
-
(1977)
J Hand Surg [Am]
, vol.2
, Issue.2
, pp. 122-126
-
-
McDowell, C.L.1
Snyder, D.M.2
-
34
-
-
0022248704
-
Factors influencing flexor tendon adhesions
-
R.H. Gelberman, and P.R. Mankse Factors influencing flexor tendon adhesions Hand Clin 1 1 1985 35 42
-
(1985)
Hand Clin
, vol.1
, Issue.1
, pp. 35-42
-
-
Gelberman, R.H.1
Mankse, P.R.2
-
35
-
-
0017968181
-
Digital pulley reconstruction employing the always present rim of the previous pulley
-
H.E. Kleinert, and J.B. Bennett Digital pulley reconstruction employing the always present rim of the previous pulley J Hand Surg 3 1978 297 298
-
(1978)
J Hand Surg
, vol.3
, pp. 297-298
-
-
Kleinert, H.E.1
Bennett, J.B.2
-
36
-
-
0023215936
-
The mechanical efficiency of the pulley system in normal digits compared with a reconstructed system using the "belt loop" technique
-
A. Karev, S. Stahl, and A. Taran The mechanical efficiency of the pulley system in normal digits compared with a reconstructed system using the "belt loop" technique J Hand Surg [Am] 12 4 1987 596 601
-
(1987)
J Hand Surg [Am]
, vol.12
, Issue.4
, pp. 596-601
-
-
Karev, A.1
Stahl, S.2
Taran, A.3
-
37
-
-
0018600674
-
Reconstruction of pulleys employing extensor retinaculum
-
G.D. Lister Reconstruction of pulleys employing extensor retinaculum J Hand Surg [Am] 4 5 1979 461 464
-
(1979)
J Hand Surg [Am]
, vol.4
, Issue.5
, pp. 461-464
-
-
Lister, G.D.1
-
38
-
-
0026553598
-
Development of a synthetic replacement for flexor tendon pulleys using expanded polytetrafluoroethylene membrane
-
B.K. Bartle, G.M. Telepun, and N.H. Goldberg Development of a synthetic replacement for flexor tendon pulleys using expanded polytetrafluoroethylene membrane Ann Plast Surg 28 3 1992 266 270
-
(1992)
Ann Plast Surg
, vol.28
, Issue.3
, pp. 266-270
-
-
Bartle, B.K.1
Telepun, G.M.2
Goldberg, N.H.3
-
39
-
-
0024417479
-
Flexor tendon pulley reconstructions - A histological and ultrastructural study in non-human primates
-
J. Dunlap, J.A. McCarthy, and P.R. Manske Flexor tendon pulley reconstructions - a histological and ultrastructural study in non-human primates J Hand Surg [Br] 14 3 1989 273 277
-
(1989)
J Hand Surg [Br]
, vol.14
, Issue.3
, pp. 273-277
-
-
Dunlap, J.1
McCarthy, J.A.2
Manske, P.R.3
-
40
-
-
0025860298
-
Reconstruction of flexor tendon pulley with expanded polytetrafluoroethylene (E-PTFE). An experimental study in rabbits
-
G. Hanff, L.B. Dahlin, and G. Lundborg Reconstruction of flexor tendon pulley with expanded polytetrafluoroethylene (E-PTFE). An experimental study in rabbits Scand J Plast Reconstr Surg Hand Surg 25 1 1991 25 30
-
(1991)
Scand J Plast Reconstr Surg Hand Surg
, vol.25
, Issue.1
, pp. 25-30
-
-
Hanff, G.1
Dahlin, L.B.2
Lundborg, G.3
-
41
-
-
18844364120
-
Staged flexor tendon reconstruction using the method of Hunter
-
L.H. Schneider Staged flexor tendon reconstruction using the method of Hunter Orthop Trans 2 1978 1
-
(1978)
Orthop Trans
, vol.2
, pp. 1
-
-
Schneider, L.H.1
-
42
-
-
0022527667
-
Two-stage flexor-tendon reconstruction. Ten-year experience
-
M.A. Wehbe, J.M. Hunter, L.H. Schneider, and B.L. Goodwyn Two-stage flexor-tendon reconstruction. Ten-year experience J Bone Joint Surg 68 5 1985 752 763
-
(1985)
J Bone Joint Surg
, vol.68
, Issue.5
, pp. 752-763
-
-
Wehbe, M.A.1
Hunter, J.M.2
Schneider, L.H.3
Goodwyn, B.L.4
-
43
-
-
0032693292
-
Bone resorption of the proximal phalanx after tendon pulley reconstruction
-
G.T. Lin Bone resorption of the proximal phalanx after tendon pulley reconstruction J Hand Surg [Am] 24 6 1999 1323 1326
-
(1999)
J Hand Surg [Am]
, vol.24
, Issue.6
, pp. 1323-1326
-
-
Lin, G.T.1
|