메뉴 건너뛰기




Volumn 174, Issue 11, 2002, Pages 1402-1407

Focal secondary malignant liver lesions: MnDPDP-enhanced MRT at 0.2 Tesla vs. Helical CT-arterioportography;Fokale maligne sekundäre leberläsionen: Manganverstärkte niederfeld-MRT bei 0,2 tesla versus spirai-CT-arterioportographie

Author keywords

Contrast media; Liver lesions; Low field MRT; MnDPDP CT AP; Open MR scanner

Indexed keywords

MANGAFODIPIR;

EID: 18744415028     PISSN: 14389029     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2002-35337     Document Type: Article
Times cited : (3)

References (21)
  • 1
    • 0019011307 scopus 로고
    • Detection of hepatic neoplasms by computed tomography in portal hepatogram phase
    • Hisa N, Hiramatsu K, Narimatsu Y, Watanabe M, Tanida I. (Detection of hepatic neoplasms by computed tomography in portal hepatogram phase [author's transl]). Rinsho Hoshasen 1980; 25: 529-534
    • (1980) Rinsho Hoshasen , vol.25 , pp. 529-534
    • Hisa, N.1    Hiramatsu, K.2    Narimatsu, Y.3    Watanabe, M.4    Tanida, I.5
  • 2
    • 0028598540 scopus 로고
    • CT during arterial portography for the preoperative evaluation of hepatic tumors: How, when, and why?
    • Soyer P, Bluemke DA, Fishman EK. CT during arterial portography for the preoperative evaluation of hepatic tumors: How, when, and why? Am J Roentgenol 1994; 163: 1325-1331
    • (1994) Am J Roentgenol , vol.163 , pp. 1325-1331
    • Soyer, P.1    Bluemke, D.A.2    Fishman, E.K.3
  • 3
    • 0027217377 scopus 로고
    • CT arterioportography in the spiral technic for the demonstration of liver metastases
    • Helmberger H, Bautz W, Vogel U, Lenz M. CT arterioportography in the spiral technic for the demonstration of liver metastases. Fortschr Röntgenstr 1993; 158: 410-415
    • (1993) Fortschr Röntgenstr , vol.158 , pp. 410-415
    • Helmberger, H.1    Bautz, W.2    Vogel, U.3    Lenz, M.4
  • 4
    • 0030917677 scopus 로고    scopus 로고
    • Methodological assessment of combined spiral CT angiography and CT arterial portography
    • Kanematsu M, Imaeda T, Hopshi H, Yokoyama R, Mizuno S. Methodological assessment of combined spiral CT angiography and CT arterial portography. Abdom Imaging 1997; 22: 404-409
    • (1997) Abdom Imaging , vol.22 , pp. 404-409
    • Kanematsu, M.1    Imaeda, T.2    Hopshi, H.3    Yokoyama, R.4    Mizuno, S.5
  • 5
    • 0027470454 scopus 로고
    • Spiral CT arterial portography of the liver
    • Bluemke DA, Fishman EK. Spiral CT arterial portography of the liver. Radiology 1993; 186: 576-579
    • (1993) Radiology , vol.186 , pp. 576-579
    • Bluemke, D.A.1    Fishman, E.K.2
  • 6
    • 0029685346 scopus 로고    scopus 로고
    • CT during arterial portography
    • Soyer P. CT during arterial portography. Eur Radiol 1996; 6: 349-357
    • (1996) Eur Radiol , vol.6 , pp. 349-357
    • Soyer, P.1
  • 7
    • 0029679778 scopus 로고    scopus 로고
    • Malignant liver lesions: Comparison of spiral CT arterial portography and MR imaging for diagnostic accuracy, cost, and effect on patient management
    • Semelka RC, Schlund JF, Molina PL, et al. Malignant liver lesions: Comparison of spiral CT arterial portography and MR imaging for diagnostic accuracy, cost, and effect on patient management. J Magn Reson Imaging 1996; 6: 39-43
    • (1996) J Magn Reson Imaging , vol.6 , pp. 39-43
    • Semelka, R.C.1    Schlund, J.F.2    Molina, P.L.3
  • 8
    • 0032886084 scopus 로고    scopus 로고
    • Liver metastases: Comparison of current MR techniques and spiral CT during arterial portography for detection in 20 surgically staged cases
    • Semelka RC, Cance WG, Marcos HB, Mauro MA. Liver metastases: Comparison of current MR techniques and spiral CT during arterial portography for detection in 20 surgically staged cases. Radiology 1999; 213: 86-91
    • (1999) Radiology , vol.213 , pp. 86-91
    • Semelka, R.C.1    Cance, W.G.2    Marcos, H.B.3    Mauro, M.A.4
  • 9
    • 0031179877 scopus 로고    scopus 로고
    • MnDPDP for MR imaging of the liver. Results from the European phase III studies (see comments)
    • Torres CG, Lundby B, Sterud AT, McGill S, Gordon PB, Bjerknes HS. MnDPDP for MR imaging of the liver. Results from the European phase III studies (see comments). Acta Radiol 1997; 38: 631-637
    • (1997) Acta Radiol , vol.38 , pp. 631-637
    • Torres, C.G.1    Lundby, B.2    Sterud, A.T.3    McGill, S.4    Gordon, P.B.5    Bjerknes, H.S.6
  • 10
    • 0031179878 scopus 로고    scopus 로고
    • Diagnostic efficacy of MnDPDP in MR imaging of the liver. A phase III multicentre study (see comments)
    • Wang C, Ahlstrom H, Ekholm S, et al. Diagnostic efficacy of MnDPDP in MR imaging of the liver. A phase III multicentre study (see comments). Acta Radiol 1997; 38: 643-649
    • (1997) Acta Radiol , vol.38 , pp. 643-649
    • Wang, C.1    Ahlstrom, H.2    Ekholm, S.3
  • 11
    • 0031184021 scopus 로고    scopus 로고
    • MnDPDP-enhanced MR imaging of the liver. Correlation with surgical findings
    • Kane PA, Ayton V, Walters HL, et al. MnDPDP-enhanced MR imaging of the liver. Correlation with surgical findings (see comments). Acta Radiol 1997; 38: 650-654
    • (1997) Acta Radiol , vol.38 , pp. 650-654
    • Kane, P.A.1    Ayton, V.2    Walters, H.L.3
  • 12
    • 0029994023 scopus 로고    scopus 로고
    • Hepatocellular carcinoma: MR imaging with mangafodipir trisodium (Mn-DPDP)
    • Murakami T, Baron RL, Peterson MS, et al. Hepatocellular carcinoma: MR imaging with mangafodipir trisodium (Mn-DPDP). Radiology 1996; 200: 69-77
    • (1996) Radiology , vol.200 , pp. 69-77
    • Murakami, T.1    Baron, R.L.2    Peterson, M.S.3
  • 13
    • 0031182269 scopus 로고    scopus 로고
    • MnDPDP for MR imaging of the liver. Results of an independent image evaluation of the European phase III studies
    • Rummeny EJ, Torres CG, Kurdziel JC, Nilsen G, Op DB, Lundby B. MnDPDP for MR imaging of the liver. Results of an independent image evaluation of the European phase III studies (see comments). Acta Radiol 1997; 38: 638-642
    • (1997) Acta Radiol , vol.38 , pp. 638-642
    • Rummeny, E.J.1    Torres, C.G.2    Kurdziel, J.C.3    Nilsen, G.4    Op, D.B.5    Lundby, B.6
  • 15
    • 0031182166 scopus 로고    scopus 로고
    • General toxicology of MnDPDP
    • Larsen LE, Grant D. General toxicology of MnDPDP. Acta Radiol 1997; 38: 770-779
    • (1997) Acta Radiol , vol.38 , pp. 770-779
    • Larsen, L.E.1    Grant, D.2
  • 16
    • 0031182136 scopus 로고    scopus 로고
    • Metabolism and pharmacokinetics of MnDPDP in man
    • Toft KG, Hustvedt SO, Grant D, et al. Metabolism and pharmacokinetics of MnDPDP in man (see comments). Acta Radiol 1997; 38: 677-689
    • (1997) Acta Radiol , vol.38 , pp. 677-689
    • Toft, K.G.1    Hustvedt, S.O.2    Grant, D.3
  • 17
    • 0030292913 scopus 로고    scopus 로고
    • Tolerability and utility of mangafodipir trisodium injection (MnDPDP) at the dose of 5 μmol/kg body weight in detecting focal liver tumors: Results of a phase III trial using an infusion technique
    • Padovani B, Lecesne R, Raffaelli C, et al. Tolerability and utility of mangafodipir trisodium injection (MnDPDP) at the dose of 5 μmol/kg body weight in detecting focal liver tumors: Results of a phase III trial using an infusion technique. Eur J Radiol 1996; 23: 205-211
    • (1996) Eur J Radiol , vol.23 , pp. 205-211
    • Padovani, B.1    Lecesne, R.2    Raffaelli, C.3
  • 18
    • 0034120262 scopus 로고    scopus 로고
    • Effects of biphasic spiral CT, conventional and iron oxide enhanced MR1 on therapy and therapy costs in patients with focal liver lesions
    • Helmberger T, Gregor M, Holzknecht N, Rau H, Scheidler J, Reiser M. Effects of biphasic spiral CT, conventional and iron oxide enhanced MR1 on therapy and therapy costs in patients with focal liver lesions. Fortschr Röntgenstr 2000; 172 (3): 251-259
    • (2000) Fortschr Röntgenstr , vol.172 , Issue.3 , pp. 251-259
    • Helmberger, T.1    Gregor, M.2    Holzknecht, N.3    Rau, H.4    Scheidler, J.5    Reiser, M.6
  • 19
    • 0030730691 scopus 로고    scopus 로고
    • MRI on low-field tomography systems (0.2 Tesla). A quantitative comparison with equipment of medium-field strength (1.0 Tesla)
    • Trattnig S, Kontaxis G, Breitenseher M, et al. MRI on low-field tomography systems (0.2 Tesla). A quantitative comparison with equipment of medium-field strength (1.0 Tesla). Radiologe 1997; 37: 773-777
    • (1997) Radiologe , vol.37 , pp. 773-777
    • Trattnig, S.1    Kontaxis, G.2    Breitenseher, M.3
  • 20
    • 0031305015 scopus 로고    scopus 로고
    • MR equipment acquisition strategies: Low-field or high-field scanners
    • Martí-Bonmatí L, Kormano M. MR equipment acquisition strategies: Low-field or high-field scanners. Eur Radiol 1997; 7 (5): 263-268
    • (1997) Eur Radiol , vol.7 , Issue.5 , pp. 263-268
    • Martí-Bonmatí, L.1    Kormano, M.2
  • 21
    • 0030625166 scopus 로고    scopus 로고
    • The influence of MR field strength on the detection of focal liver lesions with superparamagnetic iron oxide
    • Deckers F, Corthouts B, Nackaerts Y, Ozsarlak O, Parizel PM, De Schepper AM. The influence of MR field strength on the detection of focal liver lesions with superparamagnetic iron oxide. Eur Radiol 1997; 7: 887-892
    • (1997) Eur Radiol , vol.7 , pp. 887-892
    • Deckers, F.1    Corthouts, B.2    Nackaerts, Y.3    Ozsarlak, O.4    Parizel, P.M.5    De Schepper, A.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.