메뉴 건너뛰기




Volumn 127, Issue 5, 2005, Pages 776-781

Thin-film coupled fluid-solid analysis of flow through the Ahmed™ glaucoma drainage device

Author keywords

Finite Element Method; Intraocular Pressure; Lubrication Theory; Von K rm n Plate Theory

Indexed keywords

BIOMECHANICS; BIOMEDICAL ENGINEERING; COMPUTER SIMULATION; FINITE ELEMENT METHOD; FLOW INTERACTIONS; PARTIAL DIFFERENTIAL EQUATIONS; PATIENT MONITORING; POISSON RATIO; PRESSURE DROP; REGRESSION ANALYSIS; REYNOLDS NUMBER; THIN FILMS;

EID: 18744414635     PISSN: 01480731     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.1993662     Document Type: Article
Times cited : (19)

References (15)
  • 3
    • 0037314537 scopus 로고    scopus 로고
    • Intraocular pressure control and complications with two-stage insertion of the Baerveldt implant
    • Tong, L., Frazao, K., LaBree, L., and Varma, R., 2003, "Intraocular Pressure Control and Complications with Two-Stage Insertion of the Baerveldt Implant," Ophthalmology, 110(2), pp. 353-358.
    • (2003) Ophthalmology , vol.110 , Issue.2 , pp. 353-358
    • Tong, L.1    Frazao, K.2    LaBree, L.3    Varma, R.4
  • 4
    • 0029022776 scopus 로고
    • In vitro and in vivo flow characteristics of glaucoma drainage implants
    • Prata, J. A., Mermoud, A., LaBree, L., and Minckler, D. S., 1995, "In Vitro and In Vivo Flow Characteristics of Glaucoma Drainage Implants," Ophthalmology, 102, pp. 894-904.
    • (1995) Ophthalmology , vol.102 , pp. 894-904
    • Prata, J.A.1    Mermoud, A.2    LaBree, L.3    Minckler, D.S.4
  • 6
    • 0031732954 scopus 로고    scopus 로고
    • Characteristics of glaucoma drainage implants during dynamics and steady-state flow conditions
    • Francis, B. A., Cortes, A., Chen, J., and Alvarado, J. A., 1998, "Characteristics of Glaucoma Drainage Implants during Dynamics and Steady-State Flow Conditions," Ophthalmology, 105, pp. 1708-1714.
    • (1998) Ophthalmology , vol.105 , pp. 1708-1714
    • Francis, B.A.1    Cortes, A.2    Chen, J.3    Alvarado, J.A.4
  • 8
    • 0033795545 scopus 로고    scopus 로고
    • Ahmed glaucoma valve implant vs trabeculectomy in the surgical treatment of glaucoma
    • Wilson, M. R., Mendis, U., Smith, S. D., and Paliwal, A., 2000, "Ahmed Glaucoma Valve Implant Vs Trabeculectomy in the Surgical Treatment of Glaucoma," Am. J. Ophthalmol., 130, pp. 267-273.
    • (2000) Am. J. Ophthalmol. , vol.130 , pp. 267-273
    • Wilson, M.R.1    Mendis, U.2    Smith, S.D.3    Paliwal, A.4
  • 13
    • 0000048673 scopus 로고
    • Gmres: A generalized minimal residual algorithm for solving nonsymmetric linear systems
    • Saad, Y., and Schultz, M. H., 1986, "Gmres: A Generalized Minimal Residual Algorithm for Solving Nonsymmetric Linear Systems," SIAM (Soc. Ind. Appl. Math.) J. Sci. Stat. Comput., 7, pp. 856-869.
    • (1986) SIAM (Soc. Ind. Appl. Math.) J. Sci. Stat. Comput. , vol.7 , pp. 856-869
    • Saad, Y.1    Schultz, M.H.2
  • 14
    • 0345304343 scopus 로고    scopus 로고
    • Aqueous shunt devices compared with trabeculectomy with mitomycin-C for children in the first two years of life
    • Beck, A. D., Sharon, F., Kammer, J., and Jin, J., 2003, "Aqueous Shunt Devices Compared with Trabeculectomy with Mitomycin-C for Children in the First Two Years of Life," Am. J. Ophthalmol., 136(6), pp. 994-1000.
    • (2003) Am. J. Ophthalmol. , vol.136 , Issue.6 , pp. 994-1000
    • Beck, A.D.1    Sharon, F.2    Kammer, J.3    Jin, J.4
  • 15
    • 0344441365 scopus 로고    scopus 로고
    • Evaluation of the hypertensive phase after insertion of the Ahmed glaucoma valve
    • Nouri-Mahdavi, K., and Caprioli, J., 2003, "Evaluation of the Hypertensive Phase After Insertion of the Ahmed Glaucoma Valve," Am. J. Ophthalmol., 136(6), pp. 1001-1008.
    • (2003) Am. J. Ophthalmol. , vol.136 , Issue.6 , pp. 1001-1008
    • Nouri-Mahdavi, K.1    Caprioli, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.