메뉴 건너뛰기




Volumn 28, Issue 2, 2005, Pages 53-56

Scotopic measurement of normal pupil size with the Colvard pupillometer and the Nidek auto-refractor

Author keywords

Colvard pupillometer; Nidek AR700A auto refractor; Pupil size

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; DATA ANALYSIS; EYELID CLOSURE; FEMALE; HUMAN; HUMAN EXPERIMENT; ILLUMINATION; INTERMETHOD COMPARISON; MALE; NIGHT VISION; NORMAL HUMAN; OPHTHALMOLOGY; OPTOMETRY; PHOTOPIC VISION; PRIORITY JOURNAL; PUPIL; PUPILLOMETER; STATISTICAL ANALYSIS; UNITED KINGDOM; VISUAL SYSTEM EXAMINATION;

EID: 18744410361     PISSN: 13670484     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clae.2004.12.002     Document Type: Article
Times cited : (9)

References (13)
  • 1
    • 0031302219 scopus 로고    scopus 로고
    • Pupil size in refractive
    • (letter)
    • W.S. Nixon Pupil size in refractive (letter) J Cataract Refract Surg 23 1997 1435-1436
    • (1997) J. Cataract Refract. Surg. , vol.23 , pp. 1435-1436
    • Nixon, W.S.1
  • 2
    • 0026026994 scopus 로고
    • The relationship of visual acuity, refractive error, and pupil size after radial keratotomy
    • J.T. Holladay M.J. Lynn G.O. Waring et al. III The relationship of visual acuity, refractive error, and pupil size after radial keratotomy Arch Ophthalmol 109 1991 70-76
    • (1991) Arch. Ophthalmol. , vol.109 , pp. 70-76
    • Holladay, J.T.1    Lynn, M.J.2    Waring III, G.O.3
  • 3
    • 0031789997 scopus 로고    scopus 로고
    • Preoperative measurement of scotopic pupil dilation using an office pupillometer
    • M. Colvard Preoperative measurement of scotopic pupil dilation using an office pupillometer J Cataract Refract Surg 24 1999 1594-1597
    • (1999) J. Cataract Refract. Surg. , vol.24 , pp. 1594-1597
    • Colvard, M.1
  • 4
    • 12944312812 scopus 로고    scopus 로고
    • Agreement and repeatability of infrared pupillometery and the comparison method
    • B.S. Boxer Wachler R.R. Krueger Agreement and repeatability of infrared pupillometery and the comparison method Ophthalmology 106 1999 319-323
    • (1999) Ophthalmology , vol.106 , pp. 319-323
    • Boxer Wachler, B.S.1    Krueger, R.R.2
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between the two methods of clinical measurement
    • J.M. Bland D.G. Altman Statistical methods for assessing agreement between the two methods of clinical measurement Lancet 1 1986 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0000004140 scopus 로고
    • Measurements in medicine: The analysis of method comparison studies
    • D.G. Altman J.M. Bland Measurements in medicine: The analysis of method comparison studies Statistician 32 1983 307-318
    • (1983) Statistician , vol.32 , pp. 307-318
    • Altman, D.G.1    Bland, J.M.2
  • 8
    • 0026705339 scopus 로고
    • Predicting visual performance following excimer photorefractive keratectomy
    • W.S. Baron C. Munnerlyn Predicting visual performance following excimer photorefractive keratectomy Refract Corn Surg 8 1992 355-362
    • (1992) Refract. Corn. Surg. , vol.8 , pp. 355-362
    • Baron, W.S.1    Munnerlyn, C.2
  • 9
    • 0029960641 scopus 로고    scopus 로고
    • Visual performance after photorefractive keratectomy: A prospective study
    • W. Verdon M. Bullimore R.K. Maloney Visual performance after photorefractive keratectomy: A prospective study Arch Ophthalmol 114 1996 1465-1472
    • (1996) Arch. Ophthalmol. , vol.114 , pp. 1465-1472
    • Verdon, W.1    Bullimore, M.2    Maloney, R.K.3
  • 10
    • 0037257071 scopus 로고    scopus 로고
    • Comparison of a digital and a handheld infrared pupillometer for determining scotopic pupil diameter
    • T. Kohnen E. Terzi J. Buhren E.M. Kohnen Comparison of a digital and a handheld infrared pupillometer for determining scotopic pupil diameter J Cataract Refract Surg 29 1 2003 12-117
    • (2003) J. Cataract Refract. Surg. , vol.29 , Issue.1 , pp. 12-117
    • Kohnen, T.1    Terzi, E.2    Buhren, J.3    Kohnen, E.M.4
  • 11
    • 0037325963 scopus 로고    scopus 로고
    • Effect of pupil size on visual function under monocular and binocular conditions in LASIK and non-LASIK patients
    • B.S. Boxer Wachler Effect of pupil size on visual function under monocular and binocular conditions in LASIK and non-LASIK patients J Cataract Refract Surg 29 2003 275-278
    • (2003) J. Cataract Refract. Surg. , vol.29 , pp. 275-278
    • Boxer Wachler, B.S.1
  • 12
    • 0036689774 scopus 로고    scopus 로고
    • Use of a digital infrared pupillometer to assess patient suitability for refractive surgery
    • E.S. Rosen C.L. Gore D. Taylor et al. Use of a digital infrared pupillometer to assess patient suitability for refractive surgery J Cataract Refract Surg 28 2002 1433-1438
    • (2002) J. Cataract Refract. Surg. , vol.28 , pp. 1433-1438
    • Rosen, E.S.1    Gore, C.L.2    Taylor, D.3
  • 13
    • 0033927054 scopus 로고    scopus 로고
    • Scotopic measurement of normal pupils: Colvard versus Video Vision Analyser infrared pupillometer
    • E.-M. Schnitzler M. Baumeister T. Kohnen Scotopic measurement of normal pupils: Colvard versus Video Vision Analyser infrared pupillometer J Cataract Refract Surg 26 2000 859-866
    • (2000) J. Cataract Refract. Surg. , vol.26 , pp. 859-866
    • Schnitzler, E.-M.1    Baumeister, M.2    Kohnen, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.