메뉴 건너뛰기




Volumn 20, Issue 9, 2002, Pages 649-657

De-noising of left ventricular myocardial borders in magnetic resonance images

Author keywords

Border detection; Left ventricular magnetic resonance images; Median filter; Snake; Wavelet adaptive filter

Indexed keywords

ALGORITHM; ARTICLE; AUTOMATION; CARDIOVASCULAR FUNCTION; DIASTOLE; DYNAMICS; ENDOCARDIUM; EVALUATION; FILTER; HEART LEFT VENTRICLE; HEART LEFT VENTRICLE EJECTION FRACTION; HEART MUSCLE; HUMAN; MEASUREMENT; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SIGNAL DETECTION; SIGNAL NOISE RATIO; SNAKE; SYSTOLE;

EID: 18744395747     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0730-725X(02)00592-1     Document Type: Article
Times cited : (4)

References (16)
  • 1
    • 0031240184 scopus 로고    scopus 로고
    • Methodology for evaluation of boundary detection algorithms on medical images
    • Chalana V, Kim YA. Methodology for evaluation of boundary detection algorithms on medical images. IEEE Trans Med Imag 1997;16(5):642-52.
    • (1997) IEEE Trans Med Imag , vol.16 , Issue.5 , pp. 642-652
    • Chalana, V.1    Kim, Y.A.2
  • 2
    • 0029307534 scopus 로고
    • De-noising by soft-thresholding
    • Donoho DL. De-noising by soft-thresholding. IEEE Trans Inform Theory 1995;41(3):613-27.
    • (1995) IEEE Trans Inform Theory , vol.41 , Issue.3 , pp. 613-627
    • Donoho, D.L.1
  • 3
    • 0041958932 scopus 로고
    • Ideal spatial adaptation by wavelet shrinkage
    • Donoho DL, Johnstone IM. Ideal spatial adaptation by wavelet shrinkage. Biometrika 1994;81(3):425-55.
    • (1994) Biometrika , vol.81 , Issue.3 , pp. 425-455
    • Donoho, D.L.1    Johnstone, I.M.2
  • 5
    • 0026029025 scopus 로고
    • Automated identification of left ventricular borders from spine-echo magnetic resonance images experimental and feasibility and clinical feasibility studies
    • Fleagle SR, Thedens DR, Stanford W, Ehrhardt JC, Scholz TD, Skorton DJ. Automated identification of left ventricular borders from spine-echo magnetic resonance images experimental and feasibility and clinical feasibility studies. Investigative Radiol 1991;4(April):295-303.
    • (1991) Investigative Radiol , vol.4 , Issue.APRIL , pp. 295-303
    • Fleagle, S.R.1    Thedens, D.R.2    Stanford, W.3    Ehrhardt, J.C.4    Scholz, T.D.5    Skorton, D.J.6
  • 6
    • 0034536898 scopus 로고    scopus 로고
    • Wavelet-based enhancement for detection of left ventricular myocardial boundaries in magnetic resonance images
    • Fu JC, Chai JW, Wong STC. Wavelet-based enhancement for detection of left ventricular myocardial boundaries in magnetic resonance images. Magn Reson Imag 2000;18:1135-41.
    • (2000) Magn Reson Imag , vol.18 , pp. 1135-1141
    • Fu, J.C.1    Chai, J.W.2    Wong, S.T.C.3
  • 10
    • 0024700097 scopus 로고
    • A theory for multi-resolution signal decomposition: The wavelet representation
    • Mallat SG. A theory for multi-resolution signal decomposition: The wavelet representation. IEEE Trans Pattern Anal Machine Intell 1989;11(7):674-89.
    • (1989) IEEE Trans Pattern Anal Machine Intell , vol.11 , Issue.7 , pp. 674-689
    • Mallat, S.G.1
  • 13
    • 0032216618 scopus 로고    scopus 로고
    • Detection of the carpal bone contours from 2-D Images of the wrist using a planar radial scalespace snake
    • Snel JG, Venema HW, Grimbergen CA. Detection of the carpal bone contours from 2-D Images of the wrist using a planar radial scalespace snake. IEEE Trans Med Imag 1998;17(6):1063-998.
    • (1998) IEEE Trans Med Imag , vol.17 , Issue.6 , pp. 1063-1998
    • Snel, J.G.1    Venema, H.W.2    Grimbergen, C.A.3
  • 15
    • 0032028944 scopus 로고    scopus 로고
    • Snake, shapes, and gradient vector flow
    • Xu C, Prince JL. Snake, shapes, and gradient vector flow. IEEE Trans Imag Proc 1998;7(3):359-69.
    • (1998) IEEE Trans Imag Proc , vol.7 , Issue.3 , pp. 359-369
    • Xu, C.1    Prince, J.L.2
  • 16
    • 0034310507 scopus 로고    scopus 로고
    • Border detection on digitized skin tumor images
    • Zhang X, Stoecker WV, Moss RH. Border detection on digitized skin tumor images. IEEE Trans Med Imag 2000;19(11):1128-43.
    • (2000) IEEE Trans Med Imag , vol.19 , Issue.11 , pp. 1128-1143
    • Zhang, X.1    Stoecker, W.V.2    Moss, R.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.