Volumn 26, Issue 1, 2005, Pages 39-47

The corner frequencies of the ECG amplifier for heart rate variability analysis

Author keywords

Cutoff frequency; Electrocardiography; Heart rate variability; High pass filter; Low pass filter

Indexed keywords

BANDPASS FILTERS; BUTTERWORTH FILTERS; CLINICAL RESEARCH; CRIME; CUTOFF FREQUENCY; DATA ACQUISITION; ELECTROCARDIOGRAPHY; HIGH PASS FILTERS; ITERATIVE METHODS;

EID: 18744363037     PISSN: 09673334     EISSN: 09673334     Source Type: Journal    
DOI: 10.1088/0967-3334/26/1/004     Document Type: Article
Times cited : (21)

References (15)
  • 1
    • 0032811953 scopus 로고    scopus 로고
    • Neurocardiology: The benefits of irregularity. The basics of methodology, physiology and current clinical applications
    • Aubert A E and Ramaekers D 1999 Neurocardiology: the benefits of irregularity. The basics of methodology, physiology and current clinical applications Acta. Cardiol. 54 107-20
    • (1999) Acta. Cardiol. , vol.54 , pp. 107-120
    • Aubert, A.E.1    Ramaekers, D.2
  • 4
    • 0033769021 scopus 로고    scopus 로고
    • Dynamic powerline interference subtraction from biosignals
    • Christov I I 2000 Dynamic powerline interference subtraction from biosignals J. Med. Eng. Technol. 24 169-72
    • (2000) J. Med. Eng. Technol. , vol.24 , pp. 169-172
    • Christov, I.I.1
  • 5
    • 0031171725 scopus 로고    scopus 로고
    • Improvement of resolution in measurement of electrocardiogram RR intervals by interpolation
    • Daskalov I and Christov I I 1997 Improvement of resolution in measurement of electrocardiogram RR intervals by interpolation Med. Eng. Phys. 19 375-9
    • (1997) Med. Eng. Phys. , vol.19 , pp. 375-379
    • Daskalov, I.1    Christov, I.I.2
  • 6
    • 0030032972 scopus 로고    scopus 로고
    • A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG
    • Hamilton P S 1996 A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG IEEE Trans. Biomed. Eng. 43 105-9
    • (1996) IEEE Trans. Biomed. Eng. , vol.43 , pp. 105-109
    • Hamilton, P.S.1
  • 7
    • 0037400925 scopus 로고    scopus 로고
    • Hypothesis: Respiratory sinus arrhythmia is an intrinsic resting function of cardiopulmonary system
    • Hayano J and Yasuma F 2003 Hypothesis: respiratory sinus arrhythmia is an intrinsic resting function of cardiopulmonary system Cardiovasc. Res. 58 1-9
    • (2003) Cardiovasc. Res. , vol.58 , pp. 1-9
    • Hayano, J.1    Yasuma, F.2
  • 8
    • 0035554079 scopus 로고    scopus 로고
    • Heart rate variability analysis
    • Hejjel L and Gal I 2001 Heart rate variability analysis Acta. Physiol. Hung. 88 219-30
    • (2001) Acta. Physiol. Hung. , vol.88 , pp. 219-230
    • Hejjel, L.1    Gal, I.2
  • 9
    • 0842327414 scopus 로고    scopus 로고
    • Suppression of power-line interference by analog notch filtering in the ECG signal for heart rate variability analysis: To do or not to do?
    • Hejjel L 2004 Suppression of power-line interference by analog notch filtering in the ECG signal for heart rate variability analysis: to do or not to do? Med. Sci. Monit. 10 MT2-9
    • (2004) Med. Sci. Monit. , vol.10
    • Hejjel, L.1
  • 11
    • 0036082829 scopus 로고    scopus 로고
    • Neural influences on cardiovascular variability: Possibilities and pitfalls
    • Malpas S C 2002 Neural influences on cardiovascular variability: possibilities and pitfalls Am. J. Physiol. 282 H6-20
    • (2002) Am. J. Physiol. , vol.282
    • Malpas, S.C.1
  • 12
    • 0025323306 scopus 로고
    • Sampling frequency of the electrocardiogram for spectral analysis of the heart rate variability
    • Merri M, Farden D C, Mottley J G and Titlebaum E L 1990 Sampling frequency of the electrocardiogram for spectral analysis of the heart rate variability IEEE Trans. Biomed. Eng. 37 99-106
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , pp. 99-106
    • Merri, M.1    Farden, D.C.2    Mottley, J.G.3    Titlebaum, E.L.4
  • 13
    • 0031106763 scopus 로고    scopus 로고
    • A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV
    • Ruha A, Sallinen S and Nissilä S 1997 A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV IEEE Trans. Biomed. Eng. 44 159-67
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , pp. 159-167
    • Ruha, A.1    Sallinen, S.2    Nissilä, S.3
  • 14
    • 0029928495 scopus 로고    scopus 로고
    • Heart rate variability. Standards of measurement, physiological interpretation, and clinical use
    • Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology 1996 Heart rate variability. Standards of measurement, physiological interpretation, and clinical use Circulation 93 1043-65
    • (1996) Circulation , vol.93 , pp. 1043-1065
  • 15
    • 0033387955 scopus 로고    scopus 로고
    • Normal ranges and reproducibility of statistical, geometric, frequency domain, and non-linear measures of 24-hour heart rate variability
    • Ziegler D, Piolot R, Strassburger K, Lambeck H and Dannehl K 1999 Normal ranges and reproducibility of statistical, geometric, frequency domain, and non-linear measures of 24-hour heart rate variability Horm. Metab. Res. 31 672-9
    • (1999) Horm. Metab. Res. , vol.31 , pp. 672-679
    • Ziegler, D.1    Piolot, R.2    Strassburger, K.3    Lambeck, H.4    Dannehl, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.