메뉴 건너뛰기




Volumn 82, Issue 5, 2005, Pages 420-427

A comparative study of the performance of different corneal topographers on children with respect to orthokeratology practice

Author keywords

Apical radius; Chinese; Corneal topography; Eccentricity; Elevation; Orthokeratology

Indexed keywords

LENSES; LIVING SYSTEMS STUDIES; OPTOMETERS; PATIENT REHABILITATION; VISION AIDS;

EID: 18644375389     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.OPX.0000162642.24885.71     Document Type: Article
Times cited : (26)

References (13)
  • 1
    • 0006277525 scopus 로고    scopus 로고
    • A mathematical model for corneal shape changes associated with ortho-k
    • Mountford J, Noack D. A mathematical model for corneal shape changes associated with ortho-k. Contact Lens Spectrum 1998;13: 39-45.
    • (1998) Contact Lens Spectrum , vol.13 , pp. 39-45
    • Mountford, J.1    Noack, D.2
  • 2
    • 0000556211 scopus 로고    scopus 로고
    • Orthokeratology
    • Phillips AJ, Speedwell L, eds. Oxford: Butterworth-Heinemann
    • Mountford J Orthokeratology. In: Phillips AJ, Speedwell L, eds. Contact Lenses, 4th ed. Oxford: Butterworth-Heinemann; 1997: 653-92.
    • (1997) Contact Lenses, 4th Ed. , pp. 653-692
    • Mountford, J.1
  • 3
    • 0027485509 scopus 로고
    • Computer-assisted corneal topography: Accuracy and reproducibility of the topographic modeling system
    • Legeais JM, Ren Q, Simon G, et al. Computer-assisted corneal topography: accuracy and reproducibility of the topographic modeling system. Refract Corneal Surg 1993;9:347-57.
    • (1993) Refract Corneal Surg , vol.9 , pp. 347-357
    • Legeais, J.M.1    Ren, Q.2    Simon, G.3
  • 4
    • 0028397737 scopus 로고
    • Characterization of the inherent error in a spherically-biased corneal topography system in mapping a radially aspheric surface
    • Roberts C. Characterization of the inherent error in a spherically-biased corneal topography system in mapping a radially aspheric surface. J Refract Corneal Surg 1994;10:103-16.
    • (1994) J Refract Corneal Surg , vol.10 , pp. 103-116
    • Roberts, C.1
  • 5
    • 0028946703 scopus 로고
    • Repeatability of corneal topography: The 'corneal field.'
    • Zadnik K, Friedman NE, Mutti DO. Repeatability of corneal topography: the 'corneal field.' J Refract Surg 1995;11:119-25.
    • (1995) J Refract Surg , vol.11 , pp. 119-125
    • Zadnik, K.1    Friedman, N.E.2    Mutti, D.O.3
  • 6
    • 0030009116 scopus 로고    scopus 로고
    • Height measurement of astigmatic test surfaces by a keratoscope that uses plane geometry surface reconstruction
    • Tripoli NK, Cohen KL, Obla P, et al. Height measurement of astigmatic test surfaces by a keratoscope that uses plane geometry surface reconstruction. Am J Ophthalmol 1996;121:668-76.
    • (1996) Am J Ophthalmol , vol.121 , pp. 668-676
    • Tripoli, N.K.1    Cohen, K.L.2    Obla, P.3
  • 7
    • 0031281871 scopus 로고    scopus 로고
    • Reconstruction of the corneal shape with the MasterVue Corneal Topography System
    • Campbell C. Reconstruction of the corneal shape with the MasterVue Corneal Topography System. Optom Vis Sci 1997;74:899-905.
    • (1997) Optom Vis Sci , vol.74 , pp. 899-905
    • Campbell, C.1
  • 8
    • 0034282121 scopus 로고    scopus 로고
    • The accuracy and precision performance of four videokeratoscopes in measuring test surfaces
    • Tang W, Collins MJ, Carney L, et al. The accuracy and precision performance of four videokeratoscopes in measuring test surfaces. Optom Vis Sci 2000;77:483-91.
    • (2000) Optom Vis Sci , vol.77 , pp. 483-491
    • Tang, W.1    Collins, M.J.2    Carney, L.3
  • 9
    • 0036124279 scopus 로고    scopus 로고
    • The performance of four different corneal topographers on normal human corneas and its impact on orthokeratology lens fitting
    • Cho P, Lam AK, Mountford J, et al. The performance of four different corneal topographers on normal human corneas and its impact on orthokeratology lens fitting. Optom Vis Sci 2002;79:175-83.
    • (2002) Optom Vis Sci , vol.79 , pp. 175-183
    • Cho, P.1    Lam, A.K.2    Mountford, J.3
  • 10
    • 0002692243 scopus 로고    scopus 로고
    • The reproducibility of videokeratoscope measurements as applied to the human cornea
    • Hough T, Edwards K. The reproducibility of videokeratoscope measurements as applied to the human cornea. Contact Lens Anterior Eye 1999;22:91-9.
    • (1999) Contact Lens Anterior Eye , vol.22 , pp. 91-99
    • Hough, T.1    Edwards, K.2
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1: 307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0041117604 scopus 로고
    • Corneal topography
    • Mandell RB, ed. Springfield: Thomas
    • Mandell RB. Corneal topography. In: Mandell RB, ed. Contact Lens Practice, 4th ed. Springfield: Thomas; 1988:107-16.
    • (1988) Contact Lens Practice, 4th Ed. , pp. 107-116
    • Mandell, R.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.