메뉴 건너뛰기




Volumn 4611, Issue , 2002, Pages 123-128

Synthetic cornea: Biocompatibility and optics

Author keywords

[No Author keywords available]

Indexed keywords

BIOCOMPATIBILITY; BIOMATERIALS; DELAMINATION; DISEASES; HYDROGELS; PHOTOGRAPHY; TISSUE;

EID: 18644363515     PISSN: 0277786X     EISSN: None     Source Type: Journal    
DOI: 10.1117/12.470584     Document Type: Article
Times cited : (1)

References (21)
  • 1
    • 0011060247 scopus 로고
    • Paris Didot & Mequignon, Paris, pXV 90
    • Pellier de Quensgy G.: Précis ou cours d'opérations sur la chirurgie des yeux. Paris Didot & Mequignon, Paris, Vol 1, pXV, pp 96-1031, 1789-90. and Parel J.-M.: 200 years of KPro: Pellier De Quengsy and the artificial cornea. An Inst Barraquer (Barc.) 1999; 28(S):33-41.
    • (1789) Pellier de Quensgy G.: Précis ou cours d'opérations sur la chirurgie des yeux , vol.1 , pp. 96-1031
  • 2
    • 0001903755 scopus 로고    scopus 로고
    • 200 Years of KPro: Pellier de quengsy and the artificial cornea
    • Pellier de Quensgy G.: Précis ou cours d'opérations sur la chirurgie des yeux. Paris Didot & Mequignon, Paris, Vol 1, pXV, pp 96-1031, 1789-90. and Parel J.-M.: 200 years of KPro: Pellier De Quengsy and the artificial cornea. An Inst Barraquer (Barc.) 1999; 28(S):33-41.
    • (1999) An Inst Barraquer (Barc.) , vol.28 , Issue.S , pp. 33-41
    • Parel, J.-M.1
  • 3
    • 84994465943 scopus 로고    scopus 로고
    • for KPros and allied techniques. For surface reconstruction techniques see www.ioss.org
    • www.kpro.org for KPros and allied techniques. For surface reconstruction techniques see www.ioss.org.
  • 4
    • 0001605048 scopus 로고    scopus 로고
    • PMMA/Dacron biointegrated keratoprosthesis 19 years of experience
    • Pintucci S., Pintucci F., Sarra A.: PMMA/Dacron Biointegrated keratoprosthesis 19 years of experience. An Inst Barraquer (Barc.) 2001; 30:97-99.
    • (2001) An Inst Barraquer (Barc.) , vol.30 , pp. 97-99
    • Pintucci, S.1    Pintucci, F.2    Sarra, A.3
  • 5
    • 0010984707 scopus 로고
    • Design improvement in keratoprosthesis
    • J.-M. Parel, Q. Ren, eds, Ophthalmic Technologies IV, SPIE Publishers, Bellingham WA
    • Villain F., Lacombe E., Legeais J.-M., Bos G., Rol P., Parel J.-M.: Design Improvement in keratoprosthesis. In: J.-M. Parel, Q. Ren, eds, Ophthalmic Technologies IV, SPIE Publishers, Bellingham WA, 1994, Proc 2126:346-352.
    • (1994) Proc , vol.2126 , pp. 346-352
    • Villain, F.1    Lacombe, E.2    Legeais, J.-M.3    Bos, G.4    Rol, P.5    Parel, J.-M.6
  • 6
    • 0029007140 scopus 로고
    • Keratoprosthesis with biocolonizable microporous fluorocarbon Haptic: Two year study on 24 patients
    • Legeais J.M., Renard G., Parel J.M., Savoldelli M., Pouliquen Y.: Keratoprosthesis with Biocolonizable Microporous Fluorocarbon Haptic: Two Year Study on 24 Patients. Arch Ophthalmol 1995; 113:757-763.
    • (1995) Arch Ophthalmol , vol.113 , pp. 757-763
    • Legeais, J.M.1    Renard, G.2    Parel, J.M.3    Savoldelli, M.4    Pouliquen, Y.5
  • 7
    • 0035892452 scopus 로고    scopus 로고
    • An overview of the development of artificial corneas with porous skirts and the use of PHEMA for such an application
    • Chirila T.V.: An overview of the development of artificial corneas with porous skirts and the use of PHEMA for such an application. Biomaterials; 2001; 22(24):33117-27.
    • (2001) Biomaterials , vol.22 , Issue.24
    • Chirila, T.V.1
  • 9
    • 0011062286 scopus 로고    scopus 로고
    • Late results of osteo-odonto-keratoprosthesis and tibial keratoprosthesis
    • Temprano J.: Late results of osteo-odonto-keratoprosthesis and tibial keratoprosthesis. An Inst Barraquer (Barc.) 1998; 27(S):53-65.
    • (1998) An Inst Barraquer (Barc.) , vol.27 , Issue.S , pp. 53-65
    • Temprano, J.1
  • 10
    • 84994448384 scopus 로고    scopus 로고
    • OOKP foundation, via Francesca delt'Ongaro 53, Rome 00152, Italy
    • OOKP foundation, via Francesca delt'Ongaro 53, Rome 00152, Italy.
  • 11
    • 0011017604 scopus 로고    scopus 로고
    • Intrastromal corneal biocompatibility evaluation of new transparent materials for keratoprosthesis
    • Duchesne B., Tahi H., Lacombe E., Parel J.-M. Intrastromal corneal biocompatibility evaluation of new transparent materials for keratoprosthesis. ARVO Invest Ophthalmol Vis Sci 2000, 41(4):S699.
    • (2000) ARVO Invest Ophthalmol Vis Sci , vol.41 , Issue.4 , pp. S699
    • Duchesne, B.1    Tahi, H.2    Lacombe, E.3    Parel, J.-M.4
  • 12
    • 0029768107 scopus 로고    scopus 로고
    • Non-penetrating keratoprosthesis: A new concept
    • J.-M. Parel, P.O. Rol, K.M. Joos (eds) Ophthalmic Technologies VI, SPIE Publishers, Bellingham WA
    • Duchesne B., Lacombe E., Lee W., Alfonso E., Parel J.-M.: Non-penetrating keratoprosthesis: A new concept. In: J.-M. Parel, P.O. Rol, K.M. Joos (eds) Ophthalmic Technologies VI, SPIE Publishers, Bellingham WA, 1996, Proc 2673:136-138.
    • (1996) Proc , vol.2673 , pp. 136-138
    • Duchesne, B.1    Lacombe, E.2    Lee, W.3    Alfonso, E.4    Parel, J.-M.5
  • 14
    • 0011060853 scopus 로고
    • ArF photorefractive correction of keratoprosthesis
    • J.-M. Parel, Q. Ren (eds) Ophthalmic Technologies III. publishers, Bellingham WA
    • Rol P., Parel J.-M., Lacombe E., Legeais J.M.: ArF photorefractive correction of keratoprosthesis. In J.-M. Parel, Q. Ren (eds) Ophthalmic Technologies III. Proc SPIE publishers, Bellingham WA, Vol 1877:354-357, 1993.
    • (1993) Proc SPIE , vol.1877 , pp. 354-357
    • Rol, P.1    Parel, J.-M.2    Lacombe, E.3    Legeais, J.M.4
  • 20
    • 85076787116 scopus 로고
    • Optical transmission of implantable ophthalmic biopolymers
    • J.-M. Parel, Q. Ren, eds, Ophthalmic Technologies IV, SPIE Publishers, Bellingham WA
    • Rol P., Parel J.-M., Villain F.: Optical transmission of implantable ophthalmic biopolymers. In: J.-M. Parel, Q. Ren, eds, Ophthalmic Technologies IV, SPIE Publishers, Bellingham WA, 1994, Proc 2126:353-359.
    • (1994) Proc , vol.2126 , pp. 353-359
    • Rol, P.1    Parel, J.-M.2    Villain, F.3
  • 21
    • 0011052555 scopus 로고
    • Polymers for keratoprosthetics devices
    • Villain F.L., Parel J.-M.: Polymers for keratoprosthetics devices. Refract Corneal Surg 1993, 9(3): 190-191.
    • (1993) Refract Corneal Surg , vol.9 , Issue.3 , pp. 190-191
    • Villain, F.L.1    Parel, J.-M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.