-
1
-
-
0344062750
-
Ceramic-based chemical sensors, probes and field-tests in automotive engines
-
N.F. Szabo, C.H. Lee, J.A. Trimboli, O.L. Figueroa, R. Ramamoorthy, H. Verweij, P.K. Dutta, S.W. Midlam-Mohler, A.A. Soliman, and S.A. Akbar Ceramic-based chemical sensors, probes and field-tests in automotive engines J. Mater. Sci. 38 2003 4239 4245
-
(2003)
J. Mater. Sci.
, vol.38
, pp. 4239-4245
-
-
Szabo, N.F.1
Lee, C.H.2
Trimboli, J.A.3
Figueroa, O.L.4
Ramamoorthy, R.5
Verweij, H.6
Dutta, P.K.7
Midlam-Mohler, S.W.8
Soliman, A.A.9
Akbar, S.A.10
-
3
-
-
34547378550
-
Carbon monoxide and hydrogen detection by anatase modification of titanium dioxide
-
L.D. Birkefeld, A.M. Azad, and S.A. Akbar Carbon monoxide and hydrogen detection by anatase modification of titanium dioxide J. Am. Ceram. Soc. 75 1992 2964 2968
-
(1992)
J. Am. Ceram. Soc.
, vol.75
, pp. 2964-2968
-
-
Birkefeld, L.D.1
Azad, A.M.2
Akbar, S.A.3
-
4
-
-
0000173087
-
Interaction of carbon monoxide with anatase surfaces at high temperatures: Optimization of a carbon monoxide sensor
-
P.K. Dutta, A. Ginwalla, B. Hogg, B. Patton, B. Chwieroth, Z. Liang, P. Gouma, M. Mills, and S.A. Akbar Interaction of carbon monoxide with anatase surfaces at high temperatures: optimization of a carbon monoxide sensor J. Phys. Chem. B 103 1999 4412 4422
-
(1999)
J. Phys. Chem. B
, vol.103
, pp. 4412-4422
-
-
Dutta, P.K.1
Ginwalla, A.2
Hogg, B.3
Patton, B.4
Chwieroth, B.5
Liang, Z.6
Gouma, P.7
Mills, M.8
Akbar, S.A.9
-
5
-
-
0035252946
-
Titanium dioxide-based high temperature carbon monoxide selective sensor
-
N. Savage, S.A. Akbar, and P.K. Dutta Titanium dioxide-based high temperature carbon monoxide selective sensor Sens. Actuators B 72 2001 239 248
-
(2001)
Sens. Actuators B
, vol.72
, pp. 239-248
-
-
Savage, N.1
Akbar, S.A.2
Dutta, P.K.3
-
6
-
-
0035949815
-
Composite n-p semiconducting titanium oxides as gas sensors
-
N. Savage, B. Chwieroth, A. Ginwalla, B.R. Patton, S.A. Akbar, and P.K. Dutta Composite n-p semiconducting titanium oxides as gas sensors Sens. Actuators B 79 2001 17 27
-
(2001)
Sens. Actuators B
, vol.79
, pp. 17-27
-
-
Savage, N.1
Chwieroth, B.2
Ginwalla, A.3
Patton, B.R.4
Akbar, S.A.5
Dutta, P.K.6
-
7
-
-
0037437329
-
x measurement with minimal CO interference utilizing a microporous zeolitic catalytic filter
-
x measurement with minimal CO interference utilizing a microporous zeolitic catalytic filter Sens. Actuators B 88 2003 168 177
-
(2003)
Sens. Actuators B
, vol.88
, pp. 168-177
-
-
Szabo, N.F.1
Dutta, P.K.2
-
8
-
-
0035252946
-
Titanium dioxide-based high temperature carbon monoxide selective sensor
-
N. Savage, S.A. Akbar, and P.K. Dutta Titanium dioxide-based high temperature carbon monoxide selective sensor Sens. Actuators B 72 2001 239 248
-
(2001)
Sens. Actuators B
, vol.72
, pp. 239-248
-
-
Savage, N.1
Akbar, S.A.2
Dutta, P.K.3
-
9
-
-
0342434616
-
2-based gas sensors as thick or thin films: An evaluation of the microstructure
-
2-based gas sensors as thick or thin films: an evaluation of the microstructure Ceram. Trans. 100 1999 419 428
-
(1999)
Ceram. Trans.
, vol.100
, pp. 419-428
-
-
Gouma, P.I.1
Banerjee, S.2
Mills, M.J.3
-
10
-
-
0032024366
-
Calcium zirconate for the monitoring of hydrocarbons
-
Y. Chiang, C.C. Wang, and S.A. Akbar Calcium zirconate for the monitoring of hydrocarbons Sens. Actuators B 46 1998 208 212
-
(1998)
Sens. Actuators B
, vol.46
, pp. 208-212
-
-
Chiang, Y.1
Wang, C.C.2
Akbar, S.A.3
-
11
-
-
0032676671
-
Niobium pentoxide as a lean-range oxygen sensor
-
A. Kohli, C.C. Wang, and S.A. Akbar Niobium pentoxide as a lean-range oxygen sensor Sens. Actuators B 56 1999 121 128
-
(1999)
Sens. Actuators B
, vol.56
, pp. 121-128
-
-
Kohli, A.1
Wang, C.C.2
Akbar, S.A.3
-
13
-
-
0037146561
-
A phosphate-based proton conducting solid electrolyte hydrocarbon gas sensor
-
B. Narayanan, S.A. Akbar, and P.K. Dutta A phosphate-based proton conducting solid electrolyte hydrocarbon gas sensor Sens. Actuators B 87 2002 480 486
-
(2002)
Sens. Actuators B
, vol.87
, pp. 480-486
-
-
Narayanan, B.1
Akbar, S.A.2
Dutta, P.K.3
-
14
-
-
0037512516
-
Detection of CO in a reducing, hydrous environment using CuBr as electrolyte
-
C. Reddy, P.K. Dutta, and S.A. Akbar Detection of CO in a reducing, hydrous environment using CuBr as electrolyte Sens. Actuators B 92 2003 351 355
-
(2003)
Sens. Actuators B
, vol.92
, pp. 351-355
-
-
Reddy, C.1
Dutta, P.K.2
Akbar, S.A.3
-
15
-
-
0035545615
-
2 gas sensor with lithium phosphorous oxynitride electrolyte
-
2 gas sensor with lithium phosphorous oxynitride electrolyte Sens. Actuators B 80 2001 234 242
-
(2001)
Sens. Actuators B
, vol.80
, pp. 234-242
-
-
Lee, C.1
Akbar, S.A.2
Park, C.O.3
-
17
-
-
0000756319
-
Optimum settings for automatic controllers
-
J.G. Ziegler, and N.B. Nichols Optimum settings for automatic controllers Trans. ASME 64 1942 759 768
-
(1942)
Trans. ASME
, vol.64
, pp. 759-768
-
-
Ziegler, J.G.1
Nichols, N.B.2
-
18
-
-
0035979966
-
Selective oxidation of carbon monoxide in hydrogen-rich mixtures by permeation through a platinum-loaded Y-type zeolite membrane
-
Y. Hasegawa, K. Kusakabe, and S. Morooka Selective oxidation of carbon monoxide in hydrogen-rich mixtures by permeation through a platinum-loaded Y-type zeolite membrane J. Membr. Sci. 190 2001 1 8
-
(2001)
J. Membr. Sci.
, vol.190
, pp. 1-8
-
-
Hasegawa, Y.1
Kusakabe, K.2
Morooka, S.3
|