메뉴 건너뛰기




Volumn 19, Issue 3, 2005, Pages 307-311

Bursting strength with various methods of renal artery ligation and potential mechanisms of failure

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL TISSUE; ARTERIAL PRESSURE; ARTERY CLAMP; ARTERY LIGATION; ARTERY OCCLUSION; ARTICLE; INFUSION PUMP; LAPAROSCOPIC SURGERY; NONHUMAN; PRESSURE MEASUREMENT; PRIORITY JOURNAL; RENAL ARTERY; STAPLER; STRENGTH;

EID: 18544362505     PISSN: 08927790     EISSN: None     Source Type: Journal    
DOI: 10.1089/end.2005.19.307     Document Type: Article
Times cited : (15)

References (8)
  • 1
    • 0036844758 scopus 로고    scopus 로고
    • Renovascular complications of laparoscopic donor nephrectomy
    • Hsu THS, Su L-M, Ratner LE, Kavoussi LR. Renovascular complications of laparoscopic donor nephrectomy. Urology 2002;60:811.
    • (2002) Urology , vol.60 , pp. 811
    • Hsu, T.H.S.1    Su, L.-M.2    Ratner, L.E.3    Kavoussi, L.R.4
  • 3
    • 0031990905 scopus 로고    scopus 로고
    • The use of bipolar cautery, laparoscopic coagulating shears, and vascular clips for hemostasis of small and medium sized vessels
    • Spivak H, Richardson WS, Hunter JG. The use of bipolar cautery, laparoscopic coagulating shears, and vascular clips for hemostasis of small and medium sized vessels. Surg Endosc 1998;12:183.
    • (1998) Surg Endosc , vol.12 , pp. 183
    • Spivak, H.1    Richardson, W.S.2    Hunter, J.G.3
  • 4
    • 0037306077 scopus 로고    scopus 로고
    • Evaluation of a vessel sealing system, bipolar electrosurgery, Harmonic Scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model
    • Landman J, Kerbl K, Rehman J, et al. Evaluation of a vessel sealing system, bipolar electrosurgery, Harmonic Scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model. J Urol 2003;196:697.
    • (2003) J Urol , vol.196 , pp. 697
    • Landman, J.1    Kerbl, K.2    Rehman, J.3
  • 5
    • 1842864016 scopus 로고    scopus 로고
    • Comparison of the Ti-knot device and Hem-o-lok clips with other devices commonly used for laparoscopic renal-artery ligation
    • Joseph J, Leung Y-Y, Eichel L, et al. Comparison of the Ti-knot device and Hem-o-lok clips with other devices commonly used for laparoscopic renal-artery ligation. J Endourol 2004;18:163.
    • (2004) J Endourol , vol.18 , pp. 163
    • Joseph, J.1    Leung, Y.-Y.2    Eichel, L.3
  • 7
    • 0033911308 scopus 로고    scopus 로고
    • Endovascular gastrointestinal anastomosis stapler device malfunction during laparoscopic nephrectomy: Early recognition and management
    • Chan D, Bischoff JT, Ratner LE, Kavoussi LR, Jarrett TW. Endovascular gastrointestinal anastomosis stapler device malfunction during laparoscopic nephrectomy: Early recognition and management. J Urol 2000;164:319.
    • (2000) J Urol , vol.164 , pp. 319
    • Chan, D.1    Bischoff, J.T.2    Ratner, L.E.3    Kavoussi, L.R.4    Jarrett, T.W.5
  • 8
    • 0037253536 scopus 로고    scopus 로고
    • Techniques to optimize vascular control during laparoscopic donor nephrectomy
    • Meng MV, Freise CE, Kang S-M, Duh Q-Y, Stoller ML. Techniques to optimize vascular control during laparoscopic donor nephrectomy. Urology 2003;61:93.
    • (2003) Urology , vol.61 , pp. 93
    • Meng, M.V.1    Freise, C.E.2    Kang, S.-M.3    Duh, Q.-Y.4    Stoller, M.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.