메뉴 건너뛰기




Volumn 20, Issue 1, 2004, Pages 9-16

Conductor geometry and capacitor quality for performance optimization of low-frequency birdcage coils

Author keywords

Birdcage coil; Low frequency MR probes; Magnetic resonance imaging; Signal to noise ratio

Indexed keywords

ARTICLE; CONDUCTOR; ELECTRIC CAPACITANCE; GEOMETRY; MATHEMATICAL COMPUTING; NUCLEAR MAGNETIC RESONANCE; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR OVERHAUSER EFFECT; SIGNAL NOISE RATIO;

EID: 18444398655     PISSN: 10437347     EISSN: None     Source Type: Journal    
DOI: 10.1002/cmr.b.20005     Document Type: Article
Times cited : (44)

References (29)
  • 1
    • 46549092488 scopus 로고
    • An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T
    • Hayes CE, Edelstein WA, Schenck JR, Mueller OM, Eash M. 1985. An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T. J Magn Reson 63:622-628.
    • (1985) J Magn Reson , vol.63 , pp. 622-628
    • Hayes, C.E.1    Edelstein, W.A.2    Schenck, J.R.3    Mueller, O.M.4    Eash, M.5
  • 2
    • 0000597869 scopus 로고
    • Quadrature detection coils - A further √2 improvement in sensitivity
    • Chen CN, Hoult DI, Sank VJ. 1983. Quadrature detection coils - A further √2 improvement in sensitivity. J Magn Reson 54:324-327.
    • (1983) J Magn Reson , vol.54 , pp. 324-327
    • Chen, C.N.1    Hoult, D.I.2    Sank, V.J.3
  • 6
    • 0029591808 scopus 로고
    • An efficient birdcage resonator at 2.5 MHz using a novel multilayer self-capacitance construction technique
    • Yeung D, Hutchison JMS, Lurie DJ. 1995. An efficient birdcage resonator at 2.5 MHz using a novel multilayer self-capacitance construction technique. Magn Reson Mat Phys Biol Med 3/3-4:163-168.
    • (1995) Magn Reson Mat Phys Biol Med , vol.3 , Issue.3-4 , pp. 163-168
    • Yeung, D.1    Hutchison, J.M.S.2    Lurie, D.J.3
  • 10
    • 18444366296 scopus 로고
    • The lateral skin effect in a flat conductor
    • Belevitch V. 1971. The lateral skin effect in a flat conductor. Philips Tech Rev 18:221-231.
    • (1971) Philips Tech Rev , vol.18 , pp. 221-231
    • Belevitch, V.1
  • 12
    • 0000132799 scopus 로고
    • The sensitivity of the zeugmatographic experiment involving human samples
    • Hoult DI, Lauterbur PC. 1979. The sensitivity of the zeugmatographic experiment involving human samples. J Magn Reson 34:425-433.
    • (1979) J Magn Reson , vol.34 , pp. 425-433
    • Hoult, D.I.1    Lauterbur, P.C.2
  • 14
    • 49549133678 scopus 로고
    • The signal-to-noise ratio of the nuclear magnetic resonance experiment
    • Hoult DI, Richards RE. 1976. The signal-to-noise ratio of the nuclear magnetic resonance experiment. J Magn Reson 24:71-85.
    • (1976) J Magn Reson , vol.24 , pp. 71-85
    • Hoult, D.I.1    Richards, R.E.2
  • 16
    • 0000899450 scopus 로고
    • Quick measurement of NMR-coil sensitivity with a dual-loop probe
    • Darrasse L, Kassab G. 1993. Quick measurement of NMR-coil sensitivity with a dual-loop probe. Rev Sci Instrum 64:1841-1844.
    • (1993) Rev Sci Instrum , vol.64 , pp. 1841-1844
    • Darrasse, L.1    Kassab, G.2
  • 17
    • 0034405181 scopus 로고    scopus 로고
    • The principle of reciprocity in signal strength calculations - A mathematical guide
    • Hoult DI. 2000. The principle of reciprocity in signal strength calculations - a mathematical guide. Concepts Magn Reson 12:173-187.
    • (2000) Concepts Magn Reson , vol.12 , pp. 173-187
    • Hoult, D.I.1
  • 18
    • 0002232853 scopus 로고
    • Field strength measurements in resonant cavities
    • Maier LC Jr, Slater JC. 1952. Field strength measurements in resonant cavities. J Appl Phys 23:68-77.
    • (1952) J Appl Phys , vol.23 , pp. 68-77
    • Maier Jr., L.C.1    Slater, J.C.2
  • 19
    • 0001262910 scopus 로고
    • Theory of saturation and double resonance effects in ESR spectra: RF coherence and line shapes
    • Freed JH, Leniart DS. 1967. Theory of saturation and double resonance effects in ESR spectra: RF coherence and line shapes. J Chem Phys 47:2762-2773.
    • (1967) J Chem Phys , vol.47 , pp. 2762-2773
    • Freed, J.H.1    Leniart, D.S.2
  • 21
    • 0031866179 scopus 로고    scopus 로고
    • Nitroxide free radical clearance in the live rat monitored by radio-frequency CW-EPR and PEDRI
    • Alecci M, Seimenis I, McCallum SJ, Lurie DJ, Foster MA. 1998. Nitroxide free radical clearance in the live rat monitored by radio-frequency CW-EPR and PEDRI. Phys Med Biol 43:1899-1905.
    • (1998) Phys Med Biol , vol.43 , pp. 1899-1905
    • Alecci, M.1    Seimenis, I.2    McCallum, S.J.3    Lurie, D.J.4    Foster, M.A.5
  • 24
    • 0033959514 scopus 로고    scopus 로고
    • A transmit-only/receive-only (TORO) RF system for high-field MRI/MRS applications
    • Barberi EA, Gati JS, Rutt BK, Menon RS. 2000. A transmit-only/receive- only (TORO) RF system for high-field MRI/MRS applications. Magn Reson Med 43:284-289.
    • (2000) Magn Reson Med , vol.43 , pp. 284-289
    • Barberi, E.A.1    Gati, J.S.2    Rutt, B.K.3    Menon, R.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.