Effect of tube guide assembly of closed suction system on airway pressure gradient

Author keywords

Airway pressure; Closed suction system; Flow; Tube guide assembly

Indexed keywords

AIRWAY PRESSURE; ARTICLE; ARTIFICIAL VENTILATION; BREATHING RATE; CALCULATION; CATHETER; COMPUTER PROGRAM; CONTROLLED STUDY; DATA ANALYSIS; ENDOTRACHEAL TUBE; HYPOXEMIA; LUNG COMPLIANCE; LUNG RESISTANCE; LUNG VOLUME; MEDICAL INSTRUMENTATION; PNEUMONIA; POSITIVE END EXPIRATORY PRESSURE; PRESSURE GRADIENT; PRESSURE MEASUREMENT; RECORDING; SENSOR; STATISTICAL ANALYSIS; TIDAL VOLUME; TRACHEOBRONCHIAL TOILET; VENTILATOR;

EID: 1842867131     PISSN: 09138668     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00540-003-0204-6     Document Type: Article
Times cited : (2)

References (5)
  • 2
    • 0027319302 scopus 로고
    • Continuous calculation of intratracheal pressure in tracheally intubated patients
    • Guttmann J, Eberhard L, Fabry B, Bertschmann W, Wolff G (1993) Continuous calculation of intratracheal pressure in tracheally intubated patients. Anesthesiology 79:503-513
    • (1993) Anesthesiology , vol.79 , pp. 503-513
    • Guttmann, J.1    Eberhard, L.2    Fabry, B.3    Bertschmann, W.4    Wolff, G.5
  • 3
    • 0035044375 scopus 로고    scopus 로고
    • Closed system endotracheal suctioning maintains lung volume during volume-controlled mechanical ventilation
    • Cereda M, Villa F, Colombo E, Greco G, Nacoti M, Pesenti A (2001) Closed system endotracheal suctioning maintains lung volume during volume-controlled mechanical ventilation. Intensive Care Med 27:648-654
    • (2001) Intensive Care Med. , vol.27 , pp. 648-654
    • Cereda, M.1    Villa, F.2    Colombo, E.3    Greco, G.4    Nacoti, M.5    Pesenti, A.6
  • 4
    • 0025992033 scopus 로고
    • Environmental contamination during tracheal suction: A comparison of disposable conventional catheters with a multiple use closed system device
    • Cobley M, Atkins M, Jones PL (1991) Environmental contamination during tracheal suction: A comparison of disposable conventional catheters with a multiple use closed system device. Anesthesia 46:957-961
    • (1991) Anesthesia , vol.46 , pp. 957-961
    • Cobley, M.1    Atkins, M.2    Jones, P.L.3
  • 5
    • 0033852948 scopus 로고    scopus 로고
    • Nosocomial pneumonia in mechanically ventilated patients, a prospective randomised evaluation of the Stericath closed suctioning system
    • Combes P, Fauvage B, Oleyer C (2000) Nosocomial pneumonia in mechanically ventilated patients, a prospective randomised evaluation of the Stericath closed suctioning system Intensive Care Med 26:878-882
    • (2000) Intensive Care Med. , vol.26 , pp. 878-882
    • Combes, P.1    Fauvage, B.2    Oleyer, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.