메뉴 건너뛰기




Volumn 92, Issue 4, 2004, Pages 2169-2178

Analysis of Failure of Crosslinked Polyethylene Cables because of Electrical Treeing: A Physicochemical Approach

Author keywords

Activation energy; Crosslinked polyethylene (XLPE); Differential scanning calorimetry (DSC); Thermogravimetric differential thermal analysis (TG DTA); Treeing

Indexed keywords

ACTIVATION ENERGY; CABLES; COST EFFECTIVENESS; CROSSLINKING; DIFFERENTIAL SCANNING CALORIMETRY; DIFFERENTIAL THERMAL ANALYSIS; DYNAMIC MECHANICAL ANALYSIS; ELECTRIC INSULATION; ELECTRIC POTENTIAL; STIFFNESS;

EID: 1842814091     PISSN: 00218995     EISSN: None     Source Type: Journal    
DOI: 10.1002/app.20200     Document Type: Article
Times cited : (25)

References (19)