-
2
-
-
0005458656
-
Verification of public domain control algorithms for building energy management and control systems
-
May WB. Verification of public domain control algorithms for building energy management and control systems. Nat Bur (US) NBSIR 85-3285 1985.
-
(1985)
Nat Bur (US) NBSIR 85-3285
-
-
May, W.B.1
-
3
-
-
0033627240
-
Optimal control of time-scheduled heating, ventilating and air conditioning process in buildings
-
Zaheer-uddin M. Zheng G.R. Optimal control of time-scheduled heating, ventilating and air conditioning process in buildings Energy Conversion and Management 41 1 2000 49-60
-
(2000)
Energy Conversion and Management
, vol.41
, Issue.1
, pp. 49-60
-
-
Zaheer-uddin, M.1
Zheng, G.R.2
-
4
-
-
0001517888
-
Evaluation of HVAC system operational strategies for commercial buildings
-
Ardehali M.M. Smith T.F. Evaluation of HVAC system operational strategies for commercial buildings Energy Conversion and Management 38 3 1997 225-236
-
(1997)
Energy Conversion and Management
, vol.38
, Issue.3
, pp. 225-236
-
-
Ardehali, M.M.1
Smith, T.F.2
-
5
-
-
0026535825
-
IAQ and energy management by demand controlled ventilation
-
Haghighat F. Donnini G. IAQ and energy management by demand controlled ventilation Environment Technology 13 1992 351-359
-
(1992)
Environment Technology
, vol.13
, pp. 351-359
-
-
Haghighat, F.1
Donnini, G.2
-
7
-
-
0033684307
-
Evaluation of indoor air quality using the decibel concept based on carbon dioxide and TVOC
-
Jokl M.V. Evaluation of indoor air quality using the decibel concept based on carbon dioxide and TVOC Building and Environment 35 8 2000 677-697
-
(2000)
Building and Environment
, vol.35
, Issue.8
, pp. 677-697
-
-
Jokl, M.V.1
-
8
-
-
85032069853
-
A review of the emission of VOCs from polymeric materials used in buildings
-
Yu C. Crump D. A review of the emission of VOCs from polymeric materials used in buildings Building and Environment 33 6 1998 357-374
-
(1998)
Building and Environment
, vol.33
, Issue.6
, pp. 357-374
-
-
Yu, C.1
Crump, D.2
-
9
-
-
0036639541
-
Fault-tolerant control for outdoor ventilation air flow rate in buildings based on neural network
-
Wang S.W. Chen Y.M. Fault-tolerant control for outdoor ventilation air flow rate in buildings based on neural network Building and Environment 37 7 2002 691-704
-
(2002)
Building and Environment
, vol.37
, Issue.7
, pp. 691-704
-
-
Wang, S.W.1
Chen, Y.M.2
-
10
-
-
0000610429
-
2 based occupancy detection for on-line outdoor airflow control
-
2 based occupancy detection for on-line outdoor airflow control Indoor Built Environment 7 1998 165-181
-
(1998)
Indoor Built Environment
, vol.7
, pp. 165-181
-
-
Wang, S.W.1
Jin, X.Q.2
-
11
-
-
1842650371
-
Building operating dynamic and strategies
-
ASHRAE. Atlanta: ASHRAE
-
ASHRAE. Building operating dynamic and strategies. In: 1995 ASHRAE handbook-HVAC applications, Atlanta: ASHRAE; 1995. p. 381.
-
(1995)
1995 ASHRAE Handbook-HVAC Applications
, pp. 381
-
-
-
12
-
-
0032785286
-
A new sequencing control strategy for air-handling units
-
Seem J.E. A new sequencing control strategy for air-handling units HVAC-R Research 5 1 1999 35-58
-
(1999)
HVAC-R Research
, vol.5
, Issue.1
, pp. 35-58
-
-
Seem, J.E.1
-
13
-
-
0029277136
-
Outdoor design conditions for HVAC system design and energy estimation for buildings in Hong Kong
-
Lam C. Hui C.M. Outdoor design conditions for HVAC system design and energy estimation for buildings in Hong Kong Energy and Buildings 22 1995 25-43
-
(1995)
Energy and Buildings
, vol.22
, pp. 25-43
-
-
Lam, C.1
Hui, C.M.2
-
14
-
-
0032643161
-
Dynamic simulation of building VAV air-conditioning system and evaluation of EMCS on-line control strategies
-
Wang S.W. Dynamic simulation of building VAV air-conditioning system and evaluation of EMCS on-line control strategies Building and Environment 34 6 1999 681-705
-
(1999)
Building and Environment
, vol.34
, Issue.6
, pp. 681-705
-
-
Wang, S.W.1
-
15
-
-
0042231743
-
Dynamic simulation of a building central chilling system and evaluation of EMCS on-line control strategies
-
Wang S.W. Dynamic simulation of a building central chilling system and evaluation of EMCS on-line control strategies Building and Environment 33 1 1998 1-20
-
(1998)
Building and Environment
, vol.33
, Issue.1
, pp. 1-20
-
-
Wang, S.W.1
-
16
-
-
0023027237
-
Characteristics of single and multi-blade dampers for duct air systems
-
Legg R.C. Characteristics of single and multi-blade dampers for duct air systems Building Services Engineering and Technology 7 8 1987 129-145
-
(1987)
Building Services Engineering and Technology
, vol.7
, Issue.8
, pp. 129-145
-
-
Legg, R.C.1
-
18
-
-
0005652907
-
-
ASHRAE Standard 62-1989R. (Public review draft). Atlanta: ASHRAE
-
ASHRAE Standard 62-1989R. Ventilation for acceptable indoor quality (Public review draft). Atlanta: ASHRAE; 1996.
-
(1996)
Ventilation for Acceptable Indoor Quality
-
-
-
19
-
-
0028572299
-
Experimental demonstration of nonlinear model-based-control of a heat exchanger
-
(of 3). Baltimore, MD; June
-
Paruchuri VP, Rhinehart RR. Experimental demonstration of nonlinear model-based-control of a heat exchanger. Proceedings of the American Control Conference, Part 3 (of 3). Baltimore, MD; June 1994.
-
(1994)
Proceedings of the American Control Conference
, Issue.PART 3
-
-
Paruchuri, V.P.1
Rhinehart, R.R.2
-
21
-
-
27144535399
-
-
ANSI/ASHRAE Standard 55a-1992, American Society of Heating, Refrigeration and Air-conditioning Engineers, Atlanta: ASHRAE
-
ANSI/ASHRAE Standard 55a-1992, Addendum to thermal environmental conditions for human occupancy. American Society of Heating, Refrigeration and Air-conditioning Engineers, Atlanta: ASHRAE; 1995.
-
(1995)
Addendum to Thermal Environmental Conditions for Human Occupancy
-
-
|