메뉴 건너뛰기




Volumn 35, Issue 2, 2004, Pages 183-189

Computer-assisted orthopaedic surgery: Minimally invasive hip and knee reconstruction

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ACETABULOPLASTY; ARTICLE; AUDIOVISUAL EQUIPMENT; CLIMBING; COMPETENCE; COMPUTER ASSISTED SURGERY; FEMUR; FOLLOW UP; GENERAL CONDITION IMPROVEMENT; HIP SURGERY; HUMAN; ILIAC CREST; KNEE ARTHROPLASTY; LEG LENGTH; MINIMALLY INVASIVE SURGERY; PATIENT POSITIONING; PREOPERATIVE CARE; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; SAFETY; SOFT TISSUE; SURGEON; SURGICAL INSTRUMENT; SURGICAL TRAINING; TIBIA; VISIBILITY; X RAY FILM;

EID: 1842580293     PISSN: 00305898     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0030-5898(03)00133-0     Document Type: Review
Times cited : (40)

References (19)
  • 1
    • 1842462311 scopus 로고    scopus 로고
    • CAS basics for clinicians and clinician scientists. AAOS/ORS combined symposium. Computer assisted surgery: New tools for minimally invasive approaches (ORS1)
    • New Orleans, February 5-9
    • DiGioia A. CAS basics for clinicians and clinician scientists. AAOS/ORS combined symposium. Computer assisted surgery: new tools for minimally invasive approaches (ORS1). In: 70th Annual Meeting Proceedings, Vol 4. New Orleans, February 5-9, 2003. p. 24-25.
    • (2003) 70th Annual Meeting Proceedings , vol.4 , pp. 24-25
    • Digioia, A.1
  • 2
    • 0031855096 scopus 로고    scopus 로고
    • Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear and component migration
    • Kennedy J.G., Rogers W.B., Soffee K.E.et al. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear and component migration. J Arthroplasty. 13:1998;530-534.
    • (1998) J Arthroplasty , vol.13 , pp. 530-534
    • Kennedy, J.G.1    Rogers, W.B.2    Soffee, K.E.3
  • 3
    • 0030667687 scopus 로고    scopus 로고
    • Difficult complications after hip joint replacement. Dislocation
    • Morrey B.F. Difficult complications after hip joint replacement. Dislocation. Clin Orthop Rel Res. 334:1997;179-187.
    • (1997) Clin Orthop Rel Res , vol.334 , pp. 179-187
    • Morrey, B.F.1
  • 4
    • 0026766148 scopus 로고
    • Instability after total hip arthroplasty
    • Morrey B.F. Instability after total hip arthroplasty. Orthop Clin N Am. 23:1992;237-248.
    • (1992) Orthop Clin N Am , vol.23 , pp. 237-248
    • Morrey, B.F.1
  • 5
    • 0027170064 scopus 로고
    • Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty
    • Oswald M.H., Jakob R.P., Schneider E. Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty. 8:1993;419-426.
    • (1993) J Arthroplasty , vol.8 , pp. 419-426
    • Oswald, M.H.1    Jakob, R.P.2    Schneider, E.3
  • 6
    • 0027972449 scopus 로고
    • Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty
    • Wasielewski R.C., Galante J.O., Leighty R., Natarajan R.N., Rosenberg A.G. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Rel Res. 299:1994;31-43.
    • (1994) Clin Orthop Rel Res , vol.299 , pp. 31-43
    • Wasielewski, R.C.1    Galante, J.O.2    Leighty, R.3    Natarajan, R.N.4    Rosenberg, A.G.5
  • 7
    • 0023098711 scopus 로고
    • Long term results after total condylar knee arthroplasty: Significance of radiolucent lines
    • Ecker M.L., Lotke P.A., Cella J.P., Windsor R.E. Long term results after total condylar knee arthroplasty: significance of radiolucent lines. Clin Orthop Rel Res. 216:1987;151-158.
    • (1987) Clin Orthop Rel Res , vol.216 , pp. 151-158
    • Ecker, M.L.1    Lotke, P.A.2    Cella, J.P.3    Windsor, R.E.4
  • 8
    • 1842619041 scopus 로고    scopus 로고
    • One mini-incision total hip replacement: When and when not indicated
    • New Orleans, February 5-9
    • th annual meeting proceedings. New Orleans, February 5-9, 2003. p. 114-5.
    • (2003) th Annual Meeting Proceedings , pp. 114-115
    • Sculco, T.P.1
  • 9
    • 1842566920 scopus 로고    scopus 로고
    • Two-incision micromini total hip replacement: When and when not indicated
    • New Orleans, February 5-9
    • Berger R.A. Two-incision micromini total hip replacement: when and when not indicated. AAOS 70th annual meeting proceedings. New Orleans, February 5-9, 2003. p. 113.
    • (2003) AAOS 70th Annual Meeting Proceedings , pp. 113
    • Berger, R.A.1
  • 13
    • 0347731229 scopus 로고    scopus 로고
    • HipNav: Preoperative planning and intraoperative navigational guidance for acetabular implant placement in total hip replacement surgery
    • L.P. Nolte, & R. Ganz. Bern, Switzerland: Hogrefe & Huber Publishers
    • DiGioia A.M., Simon D.A., Jaramaz B., Blackwell M., Morgan F., O'Toole R.V.et al. HipNav: preoperative planning and intraoperative navigational guidance for acetabular implant placement in total hip replacement surgery. Nolte L.P., Ganz R. Computer assisted orthopaedic surgery (CAOS). 1999;134-140 Hogrefe & Huber Publishers, Bern, Switzerland.
    • (1999) Computer Assisted Orthopaedic Surgery (CAOS) , pp. 134-140
    • Digioia, A.M.1    Simon, D.A.2    Jaramaz, B.3    Blackwell, M.4    Morgan, F.5    O'Toole, R.V.6
  • 14
    • 0031690023 scopus 로고    scopus 로고
    • Computer assisted measurement of cup placement in total hip replacement
    • Jaramaz B., DiGioia A.M. III, Blackwell M., Nikou C. Computer assisted measurement of cup placement in total hip replacement. Clin Orthop. 354:1998;70-81.
    • (1998) Clin Orthop , vol.354 , pp. 70-81
    • Jaramaz, B.1    Digioia III, A.M.2    Blackwell, M.3    Nikou, C.4
  • 17
    • 0030148248 scopus 로고    scopus 로고
    • Matching 3-D anatomical surfaces with non-rigid deformation using octree-splines
    • Fleute M., Lavallee S. Matching 3-D anatomical surfaces with non-rigid deformation using octree-splines. Int J Comp Vision. 18(2):1996;171-186.
    • (1996) Int J Comp Vision , vol.18 , Issue.2 , pp. 171-186
    • Fleute, M.1    Lavallee, S.2
  • 19
    • 0032178167 scopus 로고    scopus 로고
    • The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment
    • DiGioia A.M., Jaramaz B., Blackwell M., Simon D.A., Morgan F., Moody J.E.et al. The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop. 355:1998;8-22.
    • (1998) Clin Orthop , vol.355 , pp. 8-22
    • Digioia, A.M.1    Jaramaz, B.2    Blackwell, M.3    Simon, D.A.4    Morgan, F.5    Moody, J.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.