메뉴 건너뛰기




Volumn 29 B, Issue 2, 2004, Pages 130-134

Tension band wiring of unstable transverse fractures of the proximal and middle phalanges of the hand

Author keywords

Phalangeal fractures; Tension band wiring

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; FEMALE; FINGER FRACTURE; FRACTURE HEALING; FRACTURE REDUCTION; HAND FUNCTION; HAND RADIOGRAPHY; HUMAN; JOINT CAPSULOTOMY; KIRSCHNER WIRE; MALE; PATIENT SATISFACTION; PHYSIOTHERAPY; SURGICAL TECHNIQUE;

EID: 1842556348     PISSN: 02667681     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhsb.2003.10.013     Document Type: Article
Times cited : (11)

References (12)
  • 1
    • 0026584340 scopus 로고
    • Treatment principles for proximal and middle phalangeal fractures
    • Agee J (1992). Treatment principles for proximal and middle phalangeal fractures. Orthopedic Clinics of North America, 23: 35-40.
    • (1992) Orthopedic Clinics of North America , vol.23 , pp. 35-40
    • Agee, J.1
  • 2
    • 0036083852 scopus 로고    scopus 로고
    • Old principles revisited-traction splinting for closed proximal phalangeal fractures
    • Collins AL, Timlin M, Thornes B, O'Sullivan T (2002). Old principles revisited-traction splinting for closed proximal phalangeal fractures. Injury, 33: 235-237.
    • (2002) Injury , vol.33 , pp. 235-237
    • Collins, A.L.1    Timlin, M.2    Thornes, B.3    O'Sullivan, T.4
  • 3
    • 0032739238 scopus 로고    scopus 로고
    • Dynamic treatment of displaced proximal phalangeal fractures
    • Ebinger T, Erhard N, Kinzl L, Mentzel M (1999). Dynamic treatment of displaced proximal phalangeal fractures. Journal of Hand Surgery, 24A: 1254-1262.
    • (1999) Journal of Hand Surgery , vol.24 A , pp. 1254-1262
    • Ebinger, T.1    Erhard, N.2    Kinzl, L.3    Mentzel, M.4
  • 4
    • 0031893510 scopus 로고    scopus 로고
    • A cheap, disposable external fixator for comminuted phalangeal fractures
    • Godwin Y, Arnstein PM (1998). A cheap, disposable external fixator for comminuted phalangeal fractures. Journal of Hand Surgery, 23B: 84-85.
    • (1998) Journal of Hand Surgery , vol.23 B , pp. 84-85
    • Godwin, Y.1    Arnstein, P.M.2
  • 5
    • 0029934718 scopus 로고    scopus 로고
    • Intramedullary fixation of metacarpal and proximal phalangeal fractures of the hand
    • Gonzalez MH, Hall RF (1996). Intramedullary fixation of metacarpal and proximal phalangeal fractures of the hand. Clinical Orthopaedics and Related Research, 327: 47-54.
    • (1996) Clinical Orthopaedics and Related Research , vol.327 , pp. 47-54
    • Gonzalez, M.H.1    Hall, R.F.2
  • 6
    • 0023101186 scopus 로고
    • Treatment of unstable metacarpal and phalangeal fractures with tension band wiring techniques
    • Greene TL, Noellert RC, Belsole RJ (1987). Treatment of unstable metacarpal and phalangeal fractures with tension band wiring techniques. Clinical Orthopaedics and Related Research, 214: 78-84.
    • (1987) Clinical Orthopaedics and Related Research , vol.214 , pp. 78-84
    • Greene, T.L.1    Noellert, R.C.2    Belsole, R.J.3
  • 8
    • 0032463393 scopus 로고    scopus 로고
    • Complications and range of motion following plate fixation of metacarpal and phalangeal fractures
    • Page SM, Stern PJ (1998). Complications and range of motion following plate fixation of metacarpal and phalangeal fractures. Journal of Hand Surgery, 23A: 827-832.
    • (1998) Journal of Hand Surgery , vol.23 A , pp. 827-832
    • Page, S.M.1    Stern, P.J.2
  • 9
    • 0025974083 scopus 로고
    • Unstable phalangeal fractures: Treatment by AO screw and plate fixation
    • Pun WK, Chow SP, So YC, et al. (1991). Unstable phalangeal fractures: Treatment by AO screw and plate fixation. Journal of Hand Surgery, 16A: 113-117.
    • (1991) Journal of Hand Surgery , vol.16 A , pp. 113-117
    • Pun, W.K.1    Chow, S.P.2    So, Y.C.3
  • 10
    • 0035135607 scopus 로고    scopus 로고
    • Treatment of phalangeal fractures by tension band wiring
    • Safoury Y (2001). Treatment of phalangeal fractures by tension band wiring. Journal of Hand Surgery, 26B: 50-52.
    • (2001) Journal of Hand Surgery , vol.26 B , pp. 50-52
    • Safoury, Y.1
  • 11
    • 0022802358 scopus 로고
    • Osteosynthesis for the unstable fracture of the hand
    • Thakore HKD (1986). Osteosynthesis for the unstable fracture of the hand. Journal of Hand Surgery, 11B: 417-421.
    • (1986) Journal of Hand Surgery , vol.11 B , pp. 417-421
    • Thakore, H.K.D.1
  • 12
    • 0023932129 scopus 로고    scopus 로고
    • Comparative mechanical properties of various Kirschner wire configurations in transverse and oblique phalangeal fractures
    • Viegas SF, Ferren EL, Self J, Tencer AF (1998). Comparative mechanical properties of various Kirschner wire configurations in transverse and oblique phalangeal fractures. Journal of Hand Surgery, 13A: 246-253.
    • (1998) Journal of Hand Surgery , vol.13 A , pp. 246-253
    • Viegas, S.F.1    Ferren, E.L.2    Self, J.3    Tencer, A.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.