메뉴 건너뛰기




Volumn 86, Issue 4, 2004, Pages 763-769

Shelf Age of the Polyethylene Tibial Component and Outcome of Unicondylar Knee Arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

POLITEF;

EID: 1842526087     PISSN: 00219355     EISSN: None     Source Type: Journal    
DOI: 10.2106/00004623-200404000-00014     Document Type: Article
Times cited : (44)

References (20)
  • 1
    • 0036599928 scopus 로고    scopus 로고
    • Rapid polyethylene failure of unicondylar tibial components sterilized with gamma irradiation in air and implanted after a long shelf life
    • McGovern TF, Ammeen DJ, Collier JP, Currier BH, Engh GA. Rapid polyethylene failure of unicondylar tibial components sterilized with gamma irradiation in air and implanted after a long shelf life. J Bone Joint Surg Am. 2002;84:901-6.
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 901-906
    • McGovern, T.F.1    Ammeen, D.J.2    Collier, J.P.3    Currier, B.H.4    Engh, G.A.5
  • 4
    • 34447111968 scopus 로고
    • The etiology of chondromalacia patellae
    • Outerbridge RE. The etiology of chondromalacia patellae. J Bone Joint Surg Br. 1961;43:752-7.
    • (1961) J Bone Joint Surg Br , vol.43 , pp. 752-757
    • Outerbridge, R.E.1
  • 5
    • 0031984965 scopus 로고    scopus 로고
    • Questionnaire on the perceptions of patients about total knee replacement
    • Dawson J, Fitzpatrick R, Murray D, Carr A. Questionnaire on the perceptions of patients about total knee replacement. J Bone Joint Surg Br. 1998;80:63-9.
    • (1998) J Bone Joint Surg Br , vol.80 , pp. 63-69
    • Dawson, J.1    Fitzpatrick, R.2    Murray, D.3    Carr, A.4
  • 7
    • 0033212579 scopus 로고    scopus 로고
    • The effects of shelf life on clinical outcome for gamma sterilized polyethylene tibial components
    • Bohl JR, Bohl WR, Postak PD, Greenwald AS. The effects of shelf life on clinical outcome for gamma sterilized polyethylene tibial components. Clin Orthop. 1999;367:28-38.
    • (1999) Clin Orthop , vol.367 , pp. 28-38
    • Bohl, J.R.1    Bohl, W.R.2    Postak, P.D.3    Greenwald, A.S.4
  • 10
    • 0017267102 scopus 로고
    • Unicondylar knee replacement
    • Insall J, Walker P. Unicondylar knee replacement. Clin Orthop. 1976; 120:83-5.
    • (1976) Clin Orthop , vol.120 , pp. 83-85
    • Insall, J.1    Walker, P.2
  • 11
    • 0017819486 scopus 로고
    • Unicompartmental tibiofemoral resurfacing arthroplasty
    • Laskin RS. Unicompartmental tibiofemoral resurfacing arthroplasty. J Bone Joint Surg Am. 1978;60:182-5.
    • (1978) J Bone Joint Surg Am , vol.60 , pp. 182-185
    • Laskin, R.S.1
  • 13
    • 0036221978 scopus 로고    scopus 로고
    • Unicompartmental knee arthroplasty: 3- to 10-year results in a community hospital setting
    • Perkins TR, Gunckle W. Unicompartmental knee arthroplasty: 3- to 10-year results in a community hospital setting. J Arthroplasty. 2002;17:293-7.
    • (2002) J Arthroplasty , vol.17 , pp. 293-297
    • Perkins, T.R.1    Gunckle, W.2
  • 14
    • 0029609343 scopus 로고
    • Miller-Galante unicompartmental knee arthroplasty at 2- to 5-year follow-up evaluations
    • Voss F, Sheinkop MB, Galante JO, Barden RM, Rosenberg AG. Miller-Galante unicompartmental knee arthroplasty at 2- to 5-year follow-up evaluations. J Arthroplasty. 1995;10:764-71.
    • (1995) J Arthroplasty , vol.10 , pp. 764-771
    • Voss, F.1    Sheinkop, M.B.2    Galante, J.O.3    Barden, R.M.4    Rosenberg, A.G.5
  • 15
    • 0024836196 scopus 로고
    • Unicompartmental knee arthroplasty. A 4.5-6-year follow-up study with a metal-backed tibial component
    • Kozinn SC, Marx C, Scott RD. Unicompartmental knee arthroplasty. A 4.5-6-year follow-up study with a metal-backed tibial component. J Arthroplasty. 1989;4 Suppl:S1-10.
    • (1989) J Arthroplasty , vol.4 , Issue.SUPPL.
    • Kozinn, S.C.1    Marx, C.2    Scott, R.D.3
  • 16
    • 0029132302 scopus 로고
    • Duplication of medial erosion in unicompartmental knee arthroplasties
    • McCallum JD 3rd, Scott RD. Duplication of medial erosion in unicompartmental knee arthroplasties. J Bone Joint Surg Br. 1995;77:726-8.
    • (1995) J Bone Joint Surg Br , vol.77 , pp. 726-728
    • McCallum III, J.D.1    Scott, R.D.2
  • 17
    • 0031981873 scopus 로고    scopus 로고
    • Early catastrophic tibial component wear after unicompartmental knee arthroplasty
    • Palmer SH, Morrison PJ, Ross AC. Early catastrophic tibial component wear after unicompartmental knee arthroplasty. Clin Orthop. 1998;350:143-8.
    • (1998) Clin Orthop , vol.350 , pp. 143-148
    • Palmer, S.H.1    Morrison, P.J.2    Ross, A.C.3
  • 18
    • 0026778427 scopus 로고
    • Polyethylene wear of the PCA unicompartmental knee. Prospective 5 (4-8) year study of 120 arthrosis knees
    • Lindstrand A, Stenstrom A. Polyethylene wear of the PCA unicompartmental knee. Prospective 5 (4-8) year study of 120 arthrosis knees. Acta Orthop Scand. 1992;63:260-2.
    • (1992) Acta Orthop Scand , vol.63 , pp. 260-262
    • Lindstrand, A.1    Stenstrom, A.2
  • 19
    • 0029565812 scopus 로고
    • Porous-coated anatomic unicompartmental knee arthroplasty in osteoarthritis. A 3-to 9-year follow-up study
    • Bergenudd H. Porous-coated anatomic unicompartmental knee arthroplasty in osteoarthritis. A 3-to 9-year follow-up study. J Arthroplasty. 1995;10 Suppl:S8-13.
    • (1995) J Arthroplasty , vol.10 , Issue.SUPPL.
    • Bergenudd, H.1
  • 20
    • 0031044963 scopus 로고    scopus 로고
    • Early failure of the porous coated anatomic cemented unicompartmental knee arthroplasty. Aids to diagnosis and revision
    • Knight JL, Atwater RD, Guo J. Early failure of the porous coated anatomic cemented unicompartmental knee arthroplasty. Aids to diagnosis and revision. J Arthroplasty. 1997;12:11-20.
    • (1997) J Arthroplasty , vol.12 , pp. 11-20
    • Knight, J.L.1    Atwater, R.D.2    Guo, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.