메뉴 건너뛰기




Volumn 51, Issue 4, 2004, Pages 785-793

Resolution-Insensitive Velocity and Flow Rate Measurement in Low-Background Phase-Contrast MRA

Author keywords

Contrast enhancement; Flow measurement; Partial volume effect; Phantoms; Phase contrast

Indexed keywords

FLOW RATE; FLOW VELOCITY; MAGNETIC RESONANCE; PHANTOMS; VELOCITY;

EID: 1842481937     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20035     Document Type: Article
Times cited : (4)

References (17)
  • 1
    • 0020340302 scopus 로고
    • A flow velocity zeugmatographic interlace for NMR imaging in humans
    • Moran PR. A flow velocity zeugmatographic interlace for NMR imaging in humans. Magn Reson Imaging 1982;1:197-203.
    • (1982) Magn Reson Imaging , vol.1 , pp. 197-203
    • Moran, P.R.1
  • 5
    • 0027173206 scopus 로고
    • Nontriggered magnetic resonance blood volume flow measurements with limited spatial resolution in small vessels
    • Hofman BM, Kouwenhouven M, Sprenger M, van Rossum AC, Valk J, Westerhof N. Nontriggered magnetic resonance blood volume flow measurements with limited spatial resolution in small vessels. Magn Reson Med 1993;29:648-655.
    • (1993) Magn Reson Med , vol.29 , pp. 648-655
    • Hofman, B.M.1    Kouwenhouven, M.2    Sprenger, M.3    Van Rossum, A.C.4    Valk, J.5    Westerhof, N.6
  • 6
    • 0028840250 scopus 로고
    • Accuracy and precision of time-averaged flow as measured by nontriggered 2D phase-contrast MR angiography: A phantom study
    • Bakker CJG, Kouwenhoven M, Hoogeveen MJ, Mali WPTM. Accuracy and precision of time-averaged flow as measured by nontriggered 2D phase-contrast MR angiography: a phantom study. Magn Reson Imaging 1995;13:959-965.
    • (1995) Magn Reson Imaging , vol.13 , pp. 959-965
    • Bakker, C.J.G.1    Kouwenhoven, M.2    Hoogeveen, M.J.3    Mali, W.P.T.M.4
  • 7
    • 0027254511 scopus 로고
    • Analysis of systematic and random error in MR volumetric flow measurements
    • Wolf RL, Ehman RL, Riederer SJ, Rossman PJ. Analysis of systematic and random error in MR volumetric flow measurements. Magn Reson Med 1993;30:82-91.
    • (1993) Magn Reson Med , vol.30 , pp. 82-91
    • Wolf, R.L.1    Ehman, R.L.2    Riederer, S.J.3    Rossman, P.J.4
  • 8
    • 0027969245 scopus 로고
    • Correction of partial volume inaccuracies in quantitative phase contrast MR angiography
    • Hamilton CA. Correction of partial volume inaccuracies in quantitative phase contrast MR angiography. Magn Reson Imaging 1994;12:1127-1130.
    • (1994) Magn Reson Imaging , vol.12 , pp. 1127-1130
    • Hamilton, C.A.1
  • 10
    • 0029270436 scopus 로고
    • Correction of partial-volume effects in phase-contrast flow measurements
    • Tang C, Blatter DD, Parker DL. Correction of partial-volume effects in phase-contrast flow measurements. J Magn Reson Imaging 1995;5:175-180.
    • (1995) J Magn Reson Imaging , vol.5 , pp. 175-180
    • Tang, C.1    Blatter, D.D.2    Parker, D.L.3
  • 11
    • 0033037618 scopus 로고    scopus 로고
    • MR phase-contrast flow measurement with limited spatial resolution in small vessels: Value of model-based image analysis
    • Hoogeveen RM, Bakker CJG, Viergever MA. MR phase-contrast flow measurement with limited spatial resolution in small vessels: value of model-based image analysis. Magn Reson Med 1999;41:520-528.
    • (1999) Magn Reson Med , vol.41 , pp. 520-528
    • Hoogeveen, R.M.1    Bakker, C.J.G.2    Viergever, M.A.3
  • 13
    • 0028830695 scopus 로고
    • The voxel sensitivity function in Fourier transform imaging: Applications to magnetic resonance angiography
    • Parker DL, Du YP, Davis WL. The voxel sensitivity function in Fourier transform imaging: applications to magnetic resonance angiography. Magn Reson Med 1995;33:156-162.
    • (1995) Magn Reson Med , vol.33 , pp. 156-162
    • Parker, D.L.1    Du, Y.P.2    Davis, W.L.3
  • 14
    • 0033985935 scopus 로고    scopus 로고
    • Dealing with the subvoxel vessel position relative to the reconstruction voxel grid in 2D MR quantitative flow measurements
    • Kaandorp DW, Kopinga K, Kouwenhoven M, Wijn PF. Dealing with the subvoxel vessel position relative to the reconstruction voxel grid in 2D MR quantitative flow measurements. Magn Reson Imaging 2000;18:49-58.
    • (2000) Magn Reson Imaging , vol.18 , pp. 49-58
    • Kaandorp, D.W.1    Kopinga, K.2    Kouwenhoven, M.3    Wijn, P.F.4
  • 17
    • 0002521965 scopus 로고
    • Application of Fourier transform spectroscopy to magnetic resonance
    • Ernst RR, Anderson WA. Application of Fourier transform spectroscopy to magnetic resonance. Rev Sci Instrum 1966;37:93-102.
    • (1966) Rev Sci Instrum , vol.37 , pp. 93-102
    • Ernst, R.R.1    Anderson, W.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.